IEC 60364-5-54:2011
|
Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 60364-4-43:2008
|
Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 60228:2004
|
Conductors of insulated cables |
IEC 61984:2008
|
Connectors - Safety requirements and tests |
IEC 61310-2:2007
|
Safety of machinery - Indication, marking and actuation - Part 2: Requirements for marking |
IEC 60364-4-41:2005+AMD1:2017 CSV
|
Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60073:2002
|
Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
IEC 62023:2011
|
Structuring of technical information and documentation |
IEC 61082-4:1996
|
Preparation of documents used in electrotechnology - Part 4: Location and installation documents |
IEC 60332-1:1993
|
Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable |
IEC 61310-3:2007
|
Safety of machinery - Indication, marking and actuation - Part 3: Requirements for the location and operation of actuators |
IEC 60947-5-1 : 4.0
|
LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-1: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTROMECHANICAL CONTROL CIRCUIT DEVICES |
IEC 60076-5:2006
|
Power transformers - Part 5: Ability to withstand short circuit |
IEC 62027:2011
|
Preparation of object lists, including parts lists |
IEC 60947-7-1:2009
|
Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
IEC 61082-1:2014 RLV
|
Preparation of documents used in electrotechnology - Part 1: Rules |
IEC 60072-1:1991
|
Dimensions and output series for rotating electrical machines - Part 1: Frame numbers 56 to 400 and flange numbers 55 to 1080 |
IEC 61082-3:1993
|
Preparation of documents used in electrotechnology - Part 3: Connection diagrams, tables and lists |
IEC 61346-1:1996
|
Industrial systems, installations and equipment and industrial products - Structuring principles and reference designations - Part 1: Basic rules |
IEC 61558-1:2017
|
Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 60447:2004
|
Basic and safety principles for man-machine interface, marking and identification - Actuating principles |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV
|
Degrees of protection provided by enclosures (IP Code) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV
|
Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 60439-1:1999+AMD1:2004 CSV
|
Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies |
IEC 60364-6-61:2001
|
Electrical installations of buildings - Part 6-61: Verification - Initial verification |
ISO 12100-2:2003
|
Safety of machinery Basic concepts, general principles for design Part 2: Technical principles |
IEC 62079:2001
|
Preparation of instructions - Structuring, content and presentation |
IEC 60034-1:2017
|
Rotating electrical machines - Part 1: Rating and performance |
IEC 60072-2:1990
|
Dimensions and output series for rotating electrical machines - Part 2: Frame numbers 355 to 1000 and flange numbers 1180 to 2360 |
ISO 3864-1:2011
|
Graphical symbols Safety colours and safety signs Part 1: Design principles for safety signs and safety markings |
ISO 12100-1:2003
|
Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology, methodology |
ISO 13850:2015
|
Safety of machinery Emergency stop function Principles for design |
IEC 61310-1:2007
|
Safety of machinery - Indication, marking and actuation - Part 1: Requirements for visual, acoustic and tactile signals |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV
|
Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
IEC 60947-2:2016
|
Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
ISO 7000:2014
|
Graphical symbols for use on equipment Registered symbols |
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV
|
Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems |
IEC 61140:2016
|
Protection against electric shock - Common aspects for installation and equipment |
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV
|
Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements |
ISO 13849-1:2015
|
Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design |
IEC 60445:2017
|
Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
IEC 60664-1:2007
|
Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60364-5-52:2009
|
Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
IEC 61082-2:1993
|
Preparation of documents used in electrotechnology - Part 2: Function-oriented diagrams |
IEC 61557-3:2007
|
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance |