• 09/30199364 DC : 0

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    BS EN 13463-5 - NON-ELECTRICAL EQUIPMENT INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES - PART 5: PROTECTION BY CONSTRUCTIONAL SAFETY 'C'

    Available format(s):  Hardcopy, PDF

    Superseded date:  29-02-2012

    Language(s):  English

    Published date: 

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General
       4.1 Determination of suitability
       4.2 General requirements for equipment
       4.3 Definition of "potential ignition source" and
           "effective ignition source"
       4.4 Ingress Protection
           4.4.1 General
       4.5 Seals for moving parts
           4.5.1 Unlubricated gaskets, seals, sleeves,
                 bellows and diaphragms
           4.5.2 Stuffing box seals
           4.5.3 Lubricated seals
       4.6 Equipment lubricants/Coolants/Fluids
       4.7 Vibration
    5 Requirements for moving parts
       5.1 General
       5.2 Clearance
       5.3 Lubrication
    6 Requirements for bearings
       6.1 General
       6.2 Lubrication
       6.3 Chemical compatibility
    7 Requirements for power transmission systems
       7.1 Gear drives
       7.2 Belt drives
       7.3 Chain drives
       7.4 Other Drives
       7.5 Hydrostatic/Hydrokinetic/Pneumatic - equipment
    8 Requirements for clutches and couplings
    9 Requirements for brakes and braking systems
       9.1 Brakes used only for stopping in emergency
       9.2 Service brakes (including friction brakes and
           fluid based retarders)
       9.3 Parking brakes
    10 Requirements for springs and absorbing elements
    11 Requirements for conveyor belts
    12 Marking
    Annex A (informative) - Examples of some of the thought
            processes and principles used in the construction
            of items of equipment protected by 'Constructional
            Safety' protection
      A.1 Ignition hazard assessment relating to a Group II,
          category 2 pump, normally used in chemical industry
          A.1.1 Description of use
          A.1.2 Construction
          A.1.3 Ignition hazard assessment
          A.1.4 Determining the ignition protection
          A.1.5 The ignition hazard assessment document
          A.1.6 Marking with regard to the ignition protection
      A.2 Ignition hazard assessment relating to a Group II,
          category 1 stirrer
      A.3 Ignition hazard assessment relating to a Group II,
          category 1 compressed air motor used for tank cleaning
    Annex B (normative) - Test requirements
      B.1 "Dry run" test for lubricated sealing arrangements
      B.2 Type test for determining the maximum engaging
          time of clutch assembly
          B.2.1 Apparatus
          B.2.2 Procedure
          B.2.3 Results
          B.2.4 Reporting
      B.3 Conductivity criteria for transmission belts
    Annex C (informative) - Significant technical changes between
            this document and the previous edition of this European
            Standard
    Annex ZA (informative) - Relationship between this European
             Standard and the Essential Requirements of EU
             Directive 94/9 EC
    Bibliography

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee FSH/23
    Document Type Draft
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 1127-1:2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology
    EN 982:1996+A1:2008 Safety of machinery - Safety requirements for fluid power systems and their components - Hydraulics
    EN 1710:2005+A1:2008/AC:2010 EQUIPMENT AND COMPONENTS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES IN UNDERGROUND MINES
    EN 13463-1:2009 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
    EN 13478:2001+A1:2008 Safety of machinery - Fire prevention and protection
    EN 13463-6:2005 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source 'b'
    ISO 281:2007 Rolling bearings Dynamic load ratings and rating life
    EN 14986:2017 Design of fans working in potentially explosive atmospheres
    EN 13463-8:2003 Non-electrical equipment for potentially explosive atmospheres - Part 8: Protection by liquid immersion 'k'
    ISO 1813:2014 Belt drives — V-ribbed belts, joined V-belts and V-belts including wide section belts and hexagonal belts — Electrical conductivity of antistatic belts: Characteristics and methods of test
    EN 1127-2:2014 Explosive atmospheres - Explosion prevention and protection - Part 2: Basic concepts and methodology for mining
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    EN 983:1996+A1:2008 Safety of machinery - Safety requirements for fluid power systems and their components - Pneumatics
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    EN 50303:2000 Group I, Category M1 equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust
    CLC/TR 50404:2003 Electrostatics - Code of practice for the avoidance of hazards due to static electricity
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective