• 09/30208590 DC : 0

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    BS EN 61672-2 ED.2 - ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS

    Available format(s):  Hardcopy, PDF

    Superseded date:  31-01-2014

    Language(s):  English

    Published date: 

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Submission for testing
    5 Marking of the sound level meter and information
       in the Instruction Manual
    6 Mandatory facilities and general requirements
    7 Environmental, electrostatic, and radio-frequency tests
       7.1 General
       7.2 Expanded uncertainties for measurements of
            environmental test conditions
       7.3 Influence of static pressure
       7.4 Tolerance limits on air temperature, relative humidity
            and static pressure
       7.5 Acclimatization requirements for tests of the influence
            of air temperature and relative humidity
       7.6 Abbreviated test of the combined influence of air
            temperature and relative humidity
       7.7 Influence of air temperature
       7.8 Influence of relative humidity
       7.9 Influence of electrostatic discharges
       7.10 Influence of a.c. power-frequency and radio-frequency
            fields
            7.10.1 Sound signal
            7.10.2 AC power-frequency tests
            7.10.3 Radio-frequency tests
    8 Radio-frequency emissions and public power supply
       disturbances
    9 Electroacoustical performance tests
       9.1 General
       9.2 Indication at the calibration check frequency
       9.3 Directional response
       9.4 Tests of frequency weightings with acoustical signals
            9.4.1 General
            9.4.2 Free-field tests
            9.4.3 Closed coupler tests
            9.4.4 Conformance
            9.4.5 Random incidence
       9.5 Tests of frequency weightings with electrical signals
            9.5.1 General
            9.5.2 First alternative test procedure (variable input
                   signal level)
            9.5.3 Second alternative test procedure (constant input
                   signal level)
            9.5.4 Conformance
            9.5.5 Sound level meters with frequency weightings C
                   or Z, or flat frequency response
       9.6 Corrections for the effect of reflections from the case
            of a sound level meter and diffraction around a microphone
       9.7 Adjustments to obtain free-field or random-incidence
            sound levels
       9.8 Level linearity
            9.8.1 Tests at an air temperature near the reference
                   air temperature
            9.8.2 Tests at elevated air temperature
       9.9 Under-range indication
       9.10 Self-generated noise level
       9.11 Decay time constants for time weightings F and S
       9.12 Toneburst response for sound level meters that measure
            time-weighted sound level
       9.13 Toneburst response for sound level meters that measure
            sound exposure level or time-averaged sound level
       9.14 Response to sequences of repeated tonebursts for sound
            level meters that measure time-averaged sound level
       9.15 Overload indication
       9.16 C-weighted peak sound level
       9.17 Reset
       9.18 Electrical output
       9.19 Timing facilities
       9.20 Crosstalk in multi-channel sound level meter systems
       9.21 Power supply
    10 Pattern evaluation report

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee EPL/29
    Document Type Draft
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61183:1994 Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters
    IEC 60942:2003 Electroacoustics - Sound calibrators
    IEC 61094-1:2000 Measurement microphones - Part 1: Specifications for laboratory standard microphones
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
    ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    IEC 62585:2012 Electroacoustics - Methods to determine corrections to obtain the free-field response of a sound level meter
    IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
    CISPR 16-1:1999+AMD1:2002 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective