    BS EN 14511-3 - AIR CONDITIONERS, LIQUID CHILLING PACKAGES AND HEAT PUMPS FOR SPACE HEATING AND COOLING AND PROCESS CHILLERS, WITH ELECTRICALLY DRIVEN COMPRESSORS - PART 3: TEST METHODS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date: 

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Rating capacity test
    5 Electrical consumptions for single duct and double
      duct units
    6 Air flow rate measurement of ducted units
    7 Heat recovery test for air-cooled multisplit systems
    8 Test report
    Annex A (normative) - Calorimeter test method
    Annex B (informative) - Indoor air enthalpy test method
    Annex C (informative) - Heating capacity tests - Flow chart
            and examples of different test
    sequences
    Annex D (informative) - Conformance criteria
    Annex E (informative) - Symbols used in annexes
    Annex F (informative) - Test at system reduced capacity
    Annex G (informative) - Individual unit tests
    Annex H (normative) - Determination of the liquid pump
            efficiency
    Annex I (informative) - Rating of indoor and outdoor units
            of multisplit and modular heat
    Annex J (normative) - Air flow rate measurement
    Annex ZA (informative) - Relationship between this European
             Standard and the requirements of Commission regulation
             (EC) No 206/2012 and Commission delegated Regulation
             (EU) No 626/2011
    Bibliography

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee RHE/17
    Document Type Draft
    Publisher British Standards Institution
    Status NA

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 14825:2016 Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling - Testing and rating at part load conditions and calculation of seasonal performance
    ISO 5801:2017 Fans — Performance testing using standardized airways
    EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
    ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
    PREN 14511-2 : DRAFT 2015 AIR CONDITIONERS, LIQUID CHILLING PACKAGES AND HEAT PUMPS WITH ELECTRICALLY DRIVEN COMPRESSORS FOR SPACE HEATING AND COOLING AND PROCESS CHILLERS, USING ELECTRICALLY DRIVEN COMPRESSORS - PART 2: TEST CONDITIONS
    CEN ISO/TS 16491 : 2012 GUIDELINES FOR THE EVALUATION OF UNCERTAINTY OF MEASUREMENT IN AIR CONDITIONER AND HEAT PUMP COOLING AND HEATING CAPACITY TESTS (ISO/TS 16491:2012)
    PREN 14511-1 : DRAFT 2015 AIR CONDITIONERS, LIQUID CHILLING PACKAGES AND HEAT PUMPS FOR SPACE HEATING AND COOLING AND PROCESS CHILLERS USING ELECTRICALLY DRIVEN COMPRESSORS - PART 1: TERMS AND DEFINITIONS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective