• 99/240939 DC : DRAFT MAR 99

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    BS EN 50330-1 PHOTOVOLTAIC SEMICONDUCTOR CONVERTORS - PART 1: UTILITY INTERACTIVE FAIL SAFE PROTECTIVE INTERFACE FOR PV-LINE COMMUTATED CONVERTORS - DESIGN QUALIFICATION AND TYPE APPROVAL

    Available format(s): 

    Withdrawn date:  22-07-2013

    Language(s): 

    Published date:  23-11-2012

    Publisher:  British Standards Institution

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Purpose
    3 Normative references
    4 Requirements
      4.1 General Requirements
      4.2 Specified Requirements
    5 Type test
      5.1 The test for single fault safety, including the
          detection of faults entailing a blockage in accordance
          with 4.2, is effected by fault simulation
      5.2 The test circuit simulates islanding conditions
          under which the MSDs must defect the interruption of
          the mains circuit and disconnect the feed from the
          house-load generator by means of the switching devices
          from the mains in the affected external and neural
          conductors within 5 s (Figure 2):
      5.3 The procedure of the MSD test is as follows:
      5.4 In order to test the overvoltage and undervoltage
          controlling device, the inverter has to be connected
          via a transformer with a varying transformation ratio
          and operated at a rated a.c. voltage and a random
          output
      5.5 In order to test the a.c. voltage characteristics
          during short circuit condition, the inverter has to be
          operated at the rated output and a short circuit has to
          be caused at the output with a resistance of 1 W. The
          voltage drop at this resistance is to be measured on
          an oscilloscope from the time the short circuit has been
          produced up to the moment the stationary state has been
          reached
    6 Routine test
    7 Rechecks of automatic disconnecting facilities
    8 Installation

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee GEL/82
    Document Type Draft
    Publisher British Standards Institution
    Status Withdrawn

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 50081-1:1992 Electromagnetic compatibility - Generic emission standard - Part 1: Residential, commercial and light industry
    EN 50160 : 2010 AMD 1 2015 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
    IEC 60146-1-3:1991 Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors
    EN 60146-1-1:2010 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
    EN 61727:1995 Photovoltaic (PV) systems - Characteristics of the utility interface
    IEC 61508-5:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508)
    IEC 61727:2004 Photovoltaic (PV) systems - Characteristics of the utility interface
    IEC 61508-4:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508)
    IEC 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508)
    EN 50178:1997 Electronic equipment for use in power installations
    EN 60146-1-3:1993 Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors
    IEC 60146-1-1:2009 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
    EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
    EN 50082-2 : 95 AC 95 ELECTROMAGNETIC COMPATIBILITY - GENERIC IMMUNITY STANDARD - INDUSTRIAL ENVIRONMENT
    IEC 61508-6:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508)
    IEC 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508)
    IEC 61508-7:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508)
    IEC 61508-2:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508)
    IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective