• AAMI ISO 8638 : 2010 : R2015

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - EXTRACORPOREAL BLOOD CIRCUIT FOR HEMODIALYZERS, HEMODIAFILTERS AND HEMOFILTERS

    Available format(s): 

    Withdrawn date:  23-11-2015

    Language(s): 

    Published date:  19-11-2015

    Publisher:  Association for the Advancement of Medical Instrumentation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Glossary of equivalent standards
    Committee representation
    Background of ANSI/AAMI adoption of ISO 8638:2010
    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements
    5 Test methods
    6 Labeling
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes requirements for the single-use extracorporeal blood circuit and (integral and nonintegral) transducer protectors which are intended for use in hemodialysis, hemodiafiltration and hemofiltration.

    General Product Information - (Show below) - (Hide below)

    Committee ISO/TC 150
    Development Note Supersedes AAMI RD17. (02/2011)
    Document Type Standard
    Product Note Reconfirmed 2015
    Publisher Association for the Advancement of Medical Instrumentation
    Status Withdrawn
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 11137-1:2006 Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
    ISO 10993-4:2017 Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood
    ISO 15223-2:2010 Medical devices — Symbols to be used with medical device labels, labelling, and information to be supplied — Part 2: Symbol development, selection and validation
    ISO 8637:2010 Cardiovascular implants and extracorporeal systems Haemodialysers, haemodiafilters, haemofilters and haemoconcentrators
    ISO/TS 17665-2:2009 Sterilization of health care products — Moist heat — Part 2: Guidance on the application of ISO 17665-1
    ISO 14937:2009 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
    ISO 11135-1:2007 Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
    ISO 10993-11:2017 Biological evaluation of medical devices — Part 11: Tests for systemic toxicity
    ISO 11137-3:2017 Sterilization of health care products — Radiation — Part 3: Guidance on dosimetric aspects of development, validation and routine control
    ISO 10993-7:2008 Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals
    ISO 11137-2:2013 Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose
    ISO 7864:2016 Sterile hypodermic needles for single use — Requirements and test methods
    ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
    ISO/TS 11135-2:2008 Sterilization of health care products Ethylene oxide Part 2: Guidance on the application of ISO 11135-1
    ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
    ISO 594-2:1998 Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings
    ISO 15223-1:2016 Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements
    ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective