• ANSI INCITS 450 : 2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    INFORMATION TECHNOLOGY - FIBRE CHANNEL - PHYSICAL INTERFACE-4 (FC-PI-4)

    Available format(s):  Hardcopy, PDF

    Superseded date:  15-02-2020

    Language(s):  English

    Published date:  01-01-2009

    Publisher:  Information Technology Industry Council

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
       2.1 General
       2.2 Approved references
       2.3 References under development
       2.4 Informative references
    3 Definitions and conventions
       3.1 Definitions
       3.2 Editorial conventions
    4 FC-PI-4 structure and concepts (informative)
       4.1 Fibre Channel structure
       4.2 FC-0 general description
       4.3 FC-0 interface overview
    5 FC-PI-4 functional characteristics
       5.1 General characteristics
       5.2 FC-0 states
       5.3 Response to input data phase jumps
       5.4 Limitations on invalid code
       5.5 Receiver initialization time
       5.6 Loss of signal (Rx_LOS) function
       5.7 Speed agile ports that support speed negotiation
       5.8 Frame scrambling and emission lowering protocol
       5.9 Test patterns
       5.10 FC-PI-4 nomenclature
       5.11 Interoperability points (informative)
       5.12 Electrical TxRx connections
       5.13 FC-PI-4 variants
    6 Optical interface specification
       6.1 TxRx connections
       6.2 Laser safety issues
       6.3 SM data links
       6.4 MM data links
    7 Optical interfaces
       7.1 Optical interface general information
       7.2 SC optical interface
       7.3 LC optical interface
       7.4 MT-RJ optical interface
       7.5 MU Connector
    8 Optical fiber cable plant specification
       8.1 SM cable plant specification
       8.2 MM cable plant specification
       8.3 Connectors and splices
    9 Electrical interface specification - Single lane variants
       9.1 General electrical characteristics
       9.2 Transmitted signal characteristics
       9.3 Receive device signal characteristics
       9.4 Jitter characteristics
       9.5 Signal characteristics for 800-DF-EA-S variants
       9.6 Eye masks
       9.7 Grounding and shielding requirements at interoperability
            points
       9.8 Transmitter device characteristics
       9.9 Return loss and impedance requirements
       9.10 Receiver characteristics
       9.11 Transmitter Compliance Transfer Function
       9.12 Test loads
       9.13 Example TxRx connections
    10 Electrical cable plant and connector specifications for
       single lane variants
       10.1 Overview
       10.2 Shielding
       10.3 Cable interoperability
       10.4 Unbalanced cable connectors
       10.5 Balanced cable connectors
    11 Very long length optical interface (SM-LL-V)
       11.1 Introduction
       11.2 SM cable plant specification
       11.3 Optical fiber interface specification
       11.4 Optical fiber cable plant specification
       11.5 Cable plant loss budget
    Annexes
    A (normative) Test methods
          A.1 Transmit or receive interface
          A.2 Receive interface
    B (normative) Signal performance measurements for 400-DF-EL-S
                  and 800-DF-Ex-S electrical variants
          B.1 Introduction
          B.2 Measurement architecture requirements
          B.3 De-embedding connectors in test fixtures
          B.4 Measurement conditions for signal output (DSO) at the
               transmitter device
          B.5 Measurement conditions for signal tolerance (DST) at
               the transmitter device
          B.6 Measurement conditions for signal output (DSO) at
               the receiver device
          B.7 Measurement conditions for signal tolerance (DST)
               at the receiver device
          B.8 S-parameter measurements
          B.9 Measurement configurations for link elements
          B.10 Summary for S-parameter measurements
    C (informative) Optical cable plant usage
    D (informative) Structured cabling environment
          D.1 Specification of operating distances
          D.2 Higher connection loss operating distances
          D.3 Operating distance estimator using connection loss lines
          D.4 Notes on operating distances
    E (normative) Tx_Off and Rx_Loss of signal detection
          E.1 Background
          E.2 Scope
          E.3 Functional and timing specifications
          E.4 Optical Tx_Off and Rx_LOS signal levels
          E.5 Electrical Tx_Off signal levels
          E.6 Electrical Rx_LOS signal levels
          E.7 Methods of measurement for electrical Rx_LOS
              thresholds (informative)
    F (normative) Scrambled test patterns
          F.1 General overview
          F.2 Scrambled jitter pattern (JSPAT)
          F.3 Jitter tolerance scrambled pattern (JTSPAT)
          F.4 Encapsulated JSPAT and JTSPAT
    G (normative) Test methodology for 8GFC systems
          G.1 General overview
          G.2 Test point definitions
          G.3 Compliance boards
          G.4 Host Compliance Board
          G.5 Module compliance board
          G.6 Specification of mated host and Module Compliance Boards
          G.7 Beta and epsilon compliance test board definition
    H (informative) Passive direct attach SFP+ cable specifications
                    for 8GFC
          H.1 General overview
          H.2 SFP+ direct attach construction
          H.3 SFP+ host output specifications for passive direct
              attach cables
          H.4 Delta R input compliance test signal specifications
              calibrated at C'
          H.5 SFP+ passive direct attach cable assembly
              specifications
    I (normative) Enhanced WDP and TWDP signal processing
          I.1 General overview
          I.2 MATLAB code used for the signal processing algorithm

    Abstract - (Show below) - (Hide below)

    Specifies the physical interface portions of high performance electrical and optical link variants that support the higher level Fibre Channel protocols including FC-FS-2 and the higher Upper Level Protocols (ULPs) associated with HIPPI, SCSI, IP and others.

    General Product Information - (Show below) - (Hide below)

    Committee T11.2
    Document Type Standard
    Publisher Information Technology Industry Council
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    ANSI INCITS TR 46 : 2011 INFORMATION TECHNOLOGY - FIBRE CHANNEL - METHODOLOGIES FOR SIGNAL QUALITY SPECIFICATION (FC-MSQS)
    BS EN 62149-7:2012 Fibre optic active components and devices. Performance standards 1310 nm discrete vertical cavity surface emitting laser devices
    ANSI INCITS 461 : 2010 INFORMATION TECHNOLOGY - FIBRE CHANNEL - SWITCH FABRIC - GENERATION 5 (FC-SW-5)
    I.S. EN 62149-7:2012 FIBRE OPTIC ACTIVE COMPONENTS AND DEVICES - PERFORMANCE STANDARDS - PART 7: 1310 NM DISCRETE VERTICAL CAVITY SURFACE EMITTING LASER DEVICES (IEC 62149-7:2012 (EQV))
    EN 62149-7 : 2012 Fibre optic active components and devices - Performance standards - Part 7: 1 310 nm discrete vertical cavity surface emitting laser devices
    ANSI INCITS 485 : 2014 INFORMATION TECHNOLOGY - FIBRE CHANNEL - SINGLE-BYTE COMMAND CODE SETS MAPPING PROTOCOL - 5 (FC-SB-5)
    ANSI INCITS 479 : 2011 INFORMATION TECHNOLOGY - FIBRE CHANNEL - PHYSICAL INTERFACE - 5 (FC-PI-5)
    ANSI INCITS 488 : 2016 FIBRE CHANNEL - FRAMING AND SIGNALING - 4 (FC-FS-4)
    ANSI INCITS 508 : 2014 INFORMATION TECHNOLOGY - STORAGE MANAGEMENT - HOST BUS ADAPTER APPLICATION PROGRAMMING INTERFACE - 2ND GENERATION (SM-HBA-2)
    CEI EN 62149-7 : 2013 FIBRE OPTIC ACTIVE COMPONENTS AND DEVICES - PERFORMANCE STANDARDS - PART 7: 1310 NM DISCRETE VERTICAL CAVITY SURFACE EMITTING LASER DEVICES
    ANSI INCITS 460 : 2011 INFORMATION TECHNOLOGY - FIBRE CHANNEL - PHYSICAL INTERFACE-3 (FC-PI-3)
    IEEE 802.3-2012 IEEE Standard for Ethernet
    IEC 62149-7:2012 Fibre optic active components and devices - Performance standards - Part 7: 1 310-nm discrete vertical cavity surface emitting laser devices
    ANSI INCITS 461 : 2010 : R2015 INFORMATION TECHNOLOGY - FIBRE CHANNEL - SWITCH FABRIC - GENERATION 5 (FC-SW-5)
    ISO/IEC/IEEE 8802-3:2017 Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Standard for Ethernet

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60825-2:2004+AMD1:2006+AMD2:2010 CSV Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS)
    IEC 61754-18:2001 Fibre optic connector interfaces - Part 18: Type MT-RJ connector family
    IEC 60807-3:1990 Rectangular connectors for frequencies below 3 MHz - Part 3: Detail specification for a range of connectors with trapezoidal shaped metal shells and round contacts - Removable crimp contact types with closed crimp barrels, rear insertion/rear extraction
    IEC 61280-1-3:2010 Fibre optic communication subsystem test procedures - Part 1-3: General communication subsystems - Central wavelength and spectral width measurement
    IEC 60793-2-10:2017 Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres
    IEC 60793-1-43:2015 Optical fibres - Part 1-43: Measurement methods and test procedures - Numerical aperture measurement
    IEC 60793-2:2015 Optical fibres - Part 2: Product specifications - General
    IEEE 802.3-2012 IEEE Standard for Ethernet
    IEEE 802.3aq-2006 IEEE Standard for Information technology -- Part 3: Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications - Amendment 2: Physical Layer and Management Parameters for 10 Gb/s Operation, Type 10GBASE-LRM
    ISO/IEC 11801:2002 Information technology Generic cabling for customer premises
    IEC 60825-1:2014 Safety of laser products - Part 1: Equipment classification and requirements
    IEC 61300-2-5:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion
    IEC 60874-19-1:2007 Fibre optic interconnecting devices and passive components - Connectors for optical fibres and cables - Part 19-1: Fibre optic patch cord connector type SC-PC (floating duplex) standard terminated on multimode fibre type A1a, A1b - Detail specification
    IEC 61280-1-1:2013 Fibre optic communication subsystem basic test procedures - Part 1-1: Test procedures for general communication subsystems - Transmitter output optical power measurement for single-mode optical fibre cable
    TIA 492AAAC : B2009 DETAIL SPECIFICATION FOR 850-NM LASER-OPTIMIZED, 50-[MU]M CORE DIAMETER/125-[MU]M CLADDING DIAMETER CLASS IA GRADED-INDEX MULTIMODE OPTICAL FIBERS
    IEC 61280-4-1:2009 Fibre-optic communication subsystem test procedures - Part 4-1: Installed cable plant - Multimode attenuation measurement
    IEC 61280-2-2:2012 Fibre optic communication subsystem test procedures - Part 2-2: Digital systems - Optical eye pattern, waveform and extinction ratio measurement
    CFR 21(PTS1-99) : 0 FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 1-99
    IEC 60793-2-50:2015 Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres
    ANSI INCITS 326 : 1999 INFORMATION TECHNOLOGY - FIBRE CHANNEL - LOW-COST 10-KM OPTICAL 1063-MBAUD INTERFACE (100-SM-LC-L)
    IEC 61754-6:2013 Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 6: Type MU connector family
    IEC 61754-20:2012 Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 20: Type LC connector family
    IEC 61754-4:2013 Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 4: Type SC connector family
    ANSI INCITS 364 : 2003 INFORMATION TECHNOLOGY - FIBRE CHANNEL - 10 GIGABIT (10GFC)
    IEC 61076-3-103:2003 Connectors for electronic equipment - Part 3-103: Rectangular connectors - Detail specification for single row connectors with non-removable ribbon cable contacts on 1,25 mm pitch used for high speed serial data (HSSDC)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective