• ASTM F 2149 : 2016 : REDLINE

    Current The latest, up-to-date edition.

    Standard Test Method for Automated Analyses of Cells—the Electrical Sensing Zone Method of Enumerating and Sizing Single Cell Suspensions

    Available format(s):  PDF

    Language(s):  English

    Published date:  15-01-2016

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 13.01, 2016 Defines a procedure for both the enumeration and measurement of size distribution of most all cell types.

    Scope - (Show below) - (Hide below)

    1.1This test method, provided the limitations are understood, covers a procedure for both the enumeration and measurement of size distribution of most all cell types. The instrumentation allows for user-selectable cell size settings and is applicable to a wide range of cell types. The method works best for spherical cells, and may be less accurate if cells are not spherical, such as for discoid cells or budding yeast. The method is appropriate for suspension as well as adherent cell cultures (1).2 Results may be reported as number of cells per milliliter or total number of cells per volume of cell suspension analyzed. Size distribution may be expressed in cell diameter or volume.

    1.2Cells commonly used in tissue-engineered medical products (2) are analyzed routinely. Examples are chondrocytes (3), fibroblasts (4), and keratinocytes (5). Szabo et al. used the method for both pancreatic islet number and volume measurements (6). In addition, instrumentation using the electrical sensing zone technology was used for both count and size distribution analyses of porcine hepatocytes placed into hollow fiber cartridge extracorporeal liver assist systems. In this study (7), and others (6, 8), the automated electrical sensing zone method was validated for precision when compared to the conventional visual cell counting under a microscope using a hemocytometer. Currently, it is not possible to validate cell counting devices for accuracy, since there not a way to produce a reference sample that has a known number of cells. The electrical sensing zone method shall be validated each time it is implemented in a new laboratory, it is used on a new cell type, or the cell counting procedure is modified.

    1.3Electrical sensing zone instrumentation (commonly referred to as a Coulter counter) is manufactured by a variety of companies and is based upon electrical impedance. This test method, for cell counting and sizing, is based on the detection and measurement of changes in electrical resistance produced by a cell, suspended in a conductive liquid, traversing through a small aperture (see Fig. 1(9)). When cells are suspended in a conductive liquid, phosphate-buffered saline for instance, they function as discrete insulators. When the cell suspension is drawn through a small cylindrical aperture, the passage of each cell changes the impedance of the electrical path between two submerged electrodes located on each side of the aperture. An electrical pulse, suitable for both counting and sizing, results from the passage of each cell through the aperture. The path through the aperture, in which the cell is detected, is known as the “electronic sensing zone.” This test method permits the selective counting of cells within narrow size distribution ranges by electronic selection of the generated pulses. While the number of pulses indicates cell count, the amplitude of the electrical pulse produced depends on the cell's volume. The baseline resistance between the electrodes is due to the resistance of the conductive liquid within the boundaries of the aperture. The presence of cells within the “electronic sensing zone” raises the resistance of the conductive pathway that depends on the volume of the cell. Analyses of the behavior of cells within the aperture demonstrates that the height of the pulse produced by the cell is the parameter that most nearly shows proportionality to the cell volume.

    1.4Limitations are discussed as follows:

    1.4.1Coincidence—Occasionally, more than a single cell transverses the aperture simultaneously. Only a single larger pulse, as opposed to two individual pulses, is generated. The result is a lower cell count and higher cell volume measurement. The frequency of coincidence is a statistically predictable function of cell concentration that is corrected by the instrument. This is called coincidence correction (8). This phenomenon may be reduced by using lower cell concentrations.

    1.4.2Viability—Electrical sensing zone cell counting enumerates both viable and nonviable cells and cannot determine percent viable cells. A separate test, such as Trypan blue, is required to determine percent viable cells.

    1.4.3Cell Diameter—This is a function of the size range capability of the aperture size selected. Measurements may be made in the cell diameter range of 0.6 μm to 1200 μm. Setting the counting size range on the instrument can affect the test results, especially if the cell size has a large distribution, and should be carefully controlled to help achieve repeatability.

    1.4.4Size Range of the Aperture—The size range for a single aperture is proportional to its diameter. The response has been found to depend linearly on diameter over a range from 2 % to 80 % of the diameter. However, the aperture tube may become prone to blockage at levels greater than 60 % of diameter. Therefore, the practical operating range of the aperture is considered to be 2 % to 60 % of the diameter.

    1.4.5Humidity—10 % to 85 %.

    1.4.6Temperature—10 °C to 35 °C.

    1.4.7Electrolyte Solution—The diluent for cell suspension shall provide conductivity and have minimal effect on cell size. The electrolyte of choice is commonly phosphate-buffered saline.

    General Product Information - (Show below) - (Hide below)

    Committee F 04
    Document Type Redline
    Publisher American Society for Testing and Materials
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    17/30341492 DC : 0 BS ISO 20391-1 - BIOTECHNOLOGY - CELL COUNTING - PART 1: GENERAL GUIDANCE ON CELL COUNTING METHODS
    DIN ISO 13022 E : 2014 MEDICAL PRODUCTS CONTAINING VIABLE HUMAN CELLS - APPLICATION OF RISK MANAGEMENT AND REQUIREMENTS FOR PROCESSING PRACTICES (ISO 13022:2012)
    17/30331334 DC : 0 BS ISO 19090 - TISSUE-ENGINEERED MEDICAL PRODUCTS - BIOACTIVE CERAMICS - CELL MIGRATION ABILITY TEST FOR POROUS BODY
    ISO 20391-1:2018 Biotechnology — Cell counting — Part 1: General guidance on cell counting methods
    DIN ISO 13022:2014-06 MEDICAL PRODUCTS CONTAINING VIABLE HUMAN CELLS - APPLICATION OF RISK MANAGEMENT AND REQUIREMENTS FOR PROCESSING PRACTICES (ISO 13022:2012)
    ASTM E 2805 : 2011 Standard Practice for Measurement of the Biological Activity of Ricin
    ASTM F 3209 : 2016 Standard Guide for Autologous Platelet-Rich Plasma for Use in Tissue Engineering and Cell Therapy
    ASTM F 2739 : 2016 Standard Guide for Quantifying Cell Viability within Biomaterial Scaffolds
    ISO 13022:2012 Medical products containing viable human cells — Application of risk management and requirements for processing practices
    10/30203224 DC : 0 BS ISO 13022 - MEDICAL PRODUCTS CONTAINING VIABLE HUMAN CELLS - APPLICATION OF RISK MANAGEMENT AND REQUIREMENTS FOR PROCESSING PRACTICES
    ISO 19090:2018 Tissue-engineered medical products — Bioactive ceramics — Method to measure cell migration in porous materials
    ANSI/AAMI/ISO 13022:2012 MEDICAL PRODUCTS CONTAINING VIABLE HUMAN CELLS - APPLICATION OF RISK MANAGEMENT AND REQUIREMENTS FOR PROCESSING PRACTICES
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective