• BS 5306-5.2:1984

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Code of practice for fire extinguishing installations and equipment on premises. Halon systems Halon 1211 total flooding systems

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  25-08-2022

    Language(s):  English

    Published date:  28-09-1984

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Committees responsible
    Code of practice
    0 Introduction
    1 Scope
    2 Definitions
    3 Characteristics of Halon 1211
    4 Planning
    5 Contract arrangements
    6 System design
    7 System operation
    8 Enclosure characteristics
    9 System components
    10 System design procedure
    11 Maintenance
    12 Safety
    Appendices
    A Deep-seated fires
    B Examples of calculation of Halon 1211 quantity where
        there is natural ventilation
    C Examples of calculation of Halon 1211 quantity where
        there is forced ventilation
    D Example of design calculation for balanced system
    E Example of design calculation for unbalanced system
    Tables
    1 Physical properties of Halon 1211
    2 Quality of Halon 1211
    3 Halon 1211 flame extinguishment concentrations
    4 Halon 1211 inerting concentrations
    5 Halon 1211 total flooding quantity
    6 Pipes
    7 Maximum pipework spans
    8 Friction loss in screwed pipe fittings and valves
    9 Friction loss in welded pipe elbows
    10 Safety clearances to enable operation, inspection,
        cleaning, repairs, painting and normal maintenance
        work to be carried out
    Figures
    1 Isometric diagram of Halon 1211 pressurized to 25
        bar at 21 deg C
    2 Isometric diagram of Halon 1211 pressurized to 10.5
        bar at 21 deg C
    3 Pressure drop against mass flow rate for Halon 1211
        in galvanized steel pipes
    4 Mass flow rate per unit area against nozzle pressure
        with Halon 1211/Nitrogen for nozzle type A
    5 Mass flow rate per unit area against nozzle pressure
        with Halon 1211/Nitrogen for nozzle type B
    6 Type A nozzle
    7 Type B nozzle
    8 Example of balanced system
    9 Example of Halon 1211 mass flow rate against
        container pressure for balanced system
    10 Example of unbalanced system
    11 Example of Halon 1211 mass flow rate against
        container pressure for unbalanced system
    12 Label to be displayed at manual control
    13 Label to be displayed at entrances to hazard
    14 Extended mass flow rate of Halon 1211 to maintain
        concentration in enclosures with openings
    15 Initial amounts of Halon 1211 to produce a 2.5 %
        (V/V) residual concentration in enclosures equipped
        for mechanical mixing
    16 Initial amounts of Halon 1211 to produce a 5 %
        (V/V) residual concentration in enclosures equipped
        for mechanical mixing
    17 Initial amounts of Halon 1211 to produce a 7.5 %
        (V/V) residual concentration in enclosures equipped
        for mechanical mixing
    18 Time required for interface between effluxing Halon
        1211/air mixtures and influxing air to descend to
        the centre of enclosures not equipped for mixing

    Abstract - (Show below) - (Hide below)

    Gives recommendations for the design and installation of Halon 1211 total flooding systems on premises.

    Scope - (Show below) - (Hide below)

    This Section of this code gives recommendations for the design, installation, maintenance and safety of Halon 1211 total flooding fire extinguishing systems in buildings or plant.

    Such a system consists of an installation designed to convey Halon 1211 from storage containers for the protection of particular plant or parts of the premises against possible fire risk. Such systems may be piped or otherwise connected.

    This code provides factual data on the characteristics of Halon 1211 and the types of fire for which it is a suitable extinguishant.

    The code does not cover the design of explosion suppression systems.

    Two methods of operation, viz. manual and automatic, are described Advice is given on the selection of a system and on the operational method; also included are detailed recommendations on the design, maintenance and efficient operation of installations. Reference is also made to the part which Halon 1211 systems should play in general schemes of fire protection of premises, having regard to safety as well as efficiency.

    NOTE 1. Unless otherwise stated, all pressures are gauge pressures (in bar) 1 bar = 105 N/m2 = 105 Pa.

    NOTE 2. The titles of the publications referred to in this code are listed on the inside back cover.

    General Product Information - (Show below) - (Hide below)

    Committee FSH/18
    Development Note Supersedes 82/11026 DC. (08/2005) Reviewed and confirmed by BSI, October 2012. (09/2012)
    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    03/637076 DC : DRAFT NOV 2003 TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - SPECIFICATION FOR INSTALLATION, OPERATION AND MAINTENANCE
    BS 5588-11:1997 Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings
    BS DD9999(2005) : 2005 CODE OF PRACTICE FOR FIRE SAFETY IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS
    BS 5306-0:2011 Fire protection installations and equipment on premises Guide for selection of installed systems and other fire equipment
    BS 9999:2008 Code of practice for fire safety in the design, management and use of buildings
    BS 5306-3:1985 Fire extinguishing installations and equipment on premises Code of practice for selection, installation and maintenance of portable fire extinguishers
    DEFSTAN 02-357(PT3)/1(2003) : 2003 REQUIREMENTS FOR GASEOUS FIREFIGHTING SYSTEMS FOR MAIN MACHINERY SPACES AND COMPARTMENTS OF SURFACE SHIPS - PART 3: BCF (HALON 1211) SYSTEM
    BS 7273-1:1990 Code of practice for the operation of fire protection measures Electrical actuation of gaseous total flooding extinguishing systems.
    BS 5306-9:2015 Fire extinguishing installations and equipment on premises Recharging of portable fire extinguishers. Code of practice
    14/30295810 DC : 0 BS 5306-9 - FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - PART 9: RECHARGING OF PORTABLE FIRE EXTINGUISHERS - CODE OF PRACTICE
    BS 6701:2004 Telecommunications equipment and telecommunications cabling. Specification for installation, operation and maintenance
    BS 5306-2:1990 Fire extinguishing installations and equipment on premises Specification for sprinkler systems
    BS 6266:1992 Code of practice for fire protection for electronic data processing installations
    BS 5306-1:2006 Code of practice for fire extinguishing installations and equipment on premises Hose reels and foam inlets
    BS 6701:2010 Telecommunications equipment and telecommunications cabling. Specification for installation, operation and maintenance
    PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
    09/30202584 DC : DRAFT OCT 2009 BS 6701 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - SPECIFICATION FOR INSTALLATION, OPERATION AND MAINTENANCE
    BS 7327-1:1990 Small fixed fire extinguishers Specification for small fixed halon fire extinguishers
    BS 7083:1996 Guide to the accommodation and operating environment for information technology (IT) equipment
    BS 5908:1980 Code of practice for fire precautions in chemical plant
    BS 7273-2:1992 Code of practice for the operation of fire protection measures Mechanical actuation of gaseous total flooding and local application extinguishing systems
    BS 5306-0:1986 Fire extinguishing installations and equipment on premises Guide for the selection of installed systems and other fire equipment
    BS 5588-3:1983 Fire precautions in the design, construction and use of buildings Code of practice for office buildings
    BS 5588-12:2004 Fire precautions in the design, construction and use of buildings Managing fire safety

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 381C:1996 Specification for colours for identification, coding and special purposes
    BS 476-4:1970 Fire tests on building materials and structures Non-combustibility test for materials
    BS 1600-2:1970 Specification for dimensions of steel pipe for the petroleum industry Metric units
    BS 2051-1:1973 Tube and pipe fittings for engineering purposes Copper and copper alloys capillary and compression tube fittings for engineering purposes
    BS 1821:1982 Specification for class I oxy-acetylene welding of ferritic steel pipework for carrying fluids
    BS 5839-1:1988 Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing
    BS 1640-3:1968 Specification for steel butt-welding pipe fittings for the petroleum industry Wrought carbon and ferritic alloy steel fittings. Metric units
    BS 3351:1971 Specification for piping systems for petroleum refineries and petrochemical plants
    BS 5252:1976 Framework for colour co-ordination for building purposes
    BS 1560-2:1970 Circular flanges for pipes, valves and fittings (Class designated) Specification for steel pipe flanges (nominal sizes ½ in to 24 in). Metric dimensions
    BS 4366:1993 Specification for industrial nitrogen
    BS 5045-2:1989 Transportable gas containers Specification for steel containers of 0.5 L up to 450 L water capacity with welded seams
    BS 1387:1985 Specification for screwed and socketed steel tubes and tubulars and for plain end steel tubes suitable for welding or for screwing to BS 21 pipe threads
    BS 5045-3:1984 Transportable gas containers Specification for seamless aluminium alloy gas containers above 0.5 litre water capacity and up to 300 bar charged pressure at 15°C
    BS 3602-1:1987 Specification for steel pipes and tubes for pressure purposes: carbon and carbon manganese steel with specified elevated temperature properties Specification for seamless and electric resistance welded including induction welded tubes
    BS 2871-2:1972 Specification for copper and copper alloys. Tubes Tubes for general purposes
    BS 1740-1:1971 Specification for wrought steel pipe fittings (screwed BS 21 R-series thread) Metric units
    ASME B16.5 : 2017 PIPE FLANGES AND FLANGED FITTINGS: NPS 1/2 THROUGH NPS 24 METRIC/INCH STANDARD
    BS CP1013(1965) : LATEST EARTHING
    BS 4547:1972 Classification of fires
    ASME B16.9 : 2012 FACTORY-MADE WROUGHT BUTTWELDING FITTINGS
    BS 162:1961 Specification for electric power switchgear and associated apparatus
    BS 476-8:1972 Fire tests on building materials and structures Test methods and criteria for the fire resistance of elements of building construction
    BS 4422-4:1975 Glossary of terms associated with fire Fire protection equipment
    ASME B16.3 : 2016 MALLEABLE IRON THREADED FITTINGS: CLASSES 150 AND 300
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective