• BS EN 12952-11:2007

    Current The latest, up-to-date edition.

    Water-tube boilers and auxiliary installations Requirements for limiting devices of the boiler and accessories

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-01-2010

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements for limiters
      4.1 General
      4.2 Materials and design
      4.3 Electrical equipment
      4.4 Fault assessment
      4.5 Marking
    5 Special requirements for water level limiters
      5.1 Components
      5.2 Design
      5.3 Floating devices
      5.4 Level electrode devices
      5.5 Examination of functional capability
      5.6 Fault detection
    6 Special requirements for pressure limiters
      6.1 Components
      6.2 Additional fault assessment requirements
      6.3 Design
      6.4 Electrical equipment
      6.5 Examination of functional capability
      6.6 Fault detection
    7 Special requirements for temperature limiters
      7.1 Components
      7.2 Design
      7.3 Electrical equipment
      7.4 Examination of functional capability
    8 Special requirements for flow limiters
      8.1 Components
      8.2 Design
      8.3 Electrical equipment
      8.4 Examination of functional capability
    Annex A (informative) Limiting device
    Annex B (informative) Example of an examination plan
    Annex C (informative) Marking of limiters
    Annex D (normative) Immunity against electrical and
            electromagnetic influences - Requirements and testing
    Annex ZA (informative) Relationship between this European
             Standard and the Essential Requirements of EU
             Directive 97/23/EC
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes requirements for limiters (or limiting devices) which are incorporated into safety systems for water-tube boilers as defined in EN 12952-1.

    Scope - (Show below) - (Hide below)

    This European Standard specifies requirements for limiters (or limiting devices) which are incorporated into safety systems for water-tube boilers as defined in EN 12952-1.

    A limiter (or limiting device) can be either:

    • a safety accessory as defined in the Pressure Equipment Directive, Article 1, clause 2.1.3, and needs to include the safety logic and final actuator, or

    • one element of a safety system, for example, a self-monitoring water level sensor used as part of a safety accessory as defined in the Pressure Equipment Directive, Article 1, clause 2.1.3. The overall boiler protection function shall be provided in association with additional safety logic (where appropriate) and a final actuator.

    The design requirements and examination of functional capability for the limiters are covered in this European Standard.

    For an explanation of the extent of the limiter (or limiting device) see Figure A.1.

    General Product Information - (Show below) - (Hide below)

    Committee PVE/2
    Development Note Supersedes 99/715322 DC. (12/2007) Together with BS EN 12952-1, BS EN 12952-2, BS EN 12952-3, BS EN 12952-5, BS EN 12952-6, BS EN 12952-7 and BS EN 12952-10, it supersedes BS 1113(1999) which remains current and inactive for new design. (01/2010)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
    EN 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
    IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    1989/336/EEC : 1989 COUNCIL DIRECTIVE OF 3 MAY 1989 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY
    IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
    EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508)
    IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
    EN 61558-2-17:1997 Safety of power transformers, power supply units and similar - Part 2-17: Particular requirements for transformers for switch mode power supplies
    EN 12952-7:2012 Water-tube boilers and auxiliary installations - Part 7: Requirements for equipment for the boiler
    EN 60742:1995 Isolating transformers and safety isolating transformers - Requirements
    1973/23/EEC : 1973 COUNCIL DIRECTIVE OF 19 FEBRUARY 1973 ON THE HARMONIZATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    EN 12952-1:2015 Water-tube boilers and auxiliary installations - Part 1: General
    IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
    EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
    IEC 61558-2-17:1997 Safety of power transformers, power supply units and similar - Part2: Particular requirements for transformers for switch mode powersupplies
    EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    EN 50156-1:2015 Electrical equipment for furnaces and ancillary equipment - Part 1: Requirements for application design and installation
    EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
    EN 61140:2016 Protection against electric shock - Common aspects for installation and equipment
    EN 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
    EN 298:2012 Automatic burner control systems for burners and appliances burning gaseous or liquid fuels
    EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
    IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
    IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    EN 60730-1:2016 Automatic electrical controls - Part 1: General requirements
    1997/23/EC : 1997 DIRECTIVE 97/23/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 29 MAY 1997 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING PRESSURE EQUIPMENT
    IEC 60730-1:2013+AMD1:2015 CSV Automatic electrical controls - Part 1: General requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective