EN 13763-4 : 2003
|
EXPLOSIVES FOR CIVIL USES - DETONATORS AND RELAYS - PART 4: DETERMINATION OF RESISTANCE TO ABRASION OF LEADING WIRES AND SHOCK TUBES |
ISO/IEC 17025:2005
|
General requirements for the competence of testing and calibration laboratories |
EN 13763-1 : 2004
|
EXPLOSIVES FOR CIVIL USES - DETONATORS AND RELAYS - PART 1: REQUIREMENTS |
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION)
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST |
EN 61000-4-11:2004/A1:2017
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 13763-22 : 2003
|
EXPLOSIVES FOR CIVIL USES - DETONATORS AND RELAYS - PART 22: DETERMINATION OF CAPACITANCE, INSULATION RESISTANCE AND INSULATION BREAKDOWN OF LEADING WIRES |
EN 60068-2-1:2007
|
Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50020:2002
|
Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
EN 60068-2-2:2007
|
Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV
|
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 60068-2-64:2008
|
ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE |
IEC 61000-4-4:2012 RLV
|
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60068-2-64:2008
|
Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
1973/23/EEC : 1973
|
COUNCIL DIRECTIVE OF 19 FEBRUARY 1973 ON THE HARMONIZATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS |
EN 13763-5 : 2003
|
EXPLOSIVES FOR CIVIL USES - DETONATORS AND RELAYS - PART 5: DETERMINATION OF RESISTANCE TO CUTTING DAMAGE OF LEADING WIRES AND SHOCK TUBES |
IEC 61000-4-6 : 4.0
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS |
IEC 61000-4-6:2013
|
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 13857-1 : 2003
|
EXPLOSIVES FOR CIVIL USES - PART 1: TERMINOLOGY |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV
|
Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007
|
Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008
|
Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV
|
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 60068-2-29:1993
|
Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
EN 60068-2-78:2013
|
Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 61000-4-4:2012
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
CISPR 11:2015 RLV
|
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60068-2-29:1987
|
Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 60068-2-1:2007
|
Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 61000-4-6:2014/AC:2015
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60529:1991/AC:2016-12
|
DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005
|
Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 60068-2-32:1993
|
Basic environmental testing procedures - Part 2: Tests - Test Ed: Free fall |
IEC 60068-2-14:2009
|
Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-14:2009
|
Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 13763-6 : 2003
|
EXPLOSIVES FOR CIVIL USES - DETONATORS AND RELAYS - PART 6: DETERMINATION OF RESISTANCE TO CRACKING OF INSULATION OF LEADING WIRES AT LOW TEMPERATURES |
1994/9/EC : 1994
|
DIRECTIVE 94/9/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 23 MARCH 1994 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
IEC 60068-2-30:2005
|
Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |