• BS EN 14181:2014

    Current The latest, up-to-date edition.

    Stationary source emissions. Quality assurance of automated measuring systems

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  30-11-2014

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols and abbreviations
    5 Principle
    6 Calibration and validation of the
      AMS (QAL2)
    7 Ongoing quality assurance during
      operation (QAL3)
    8 Annual Surveillance Test (AST)
    9 Documentation
    Annex A (normative) - QAL2 and AST functional
            test of AMS
    Annex B (normative) - Test of linearity
    Annex C (informative) - Control charts
    Annex D (normative) - Documentation
    Annex E (informative) - Examples of calculation of the
            calibration function and of the variability test
    Annex F (informative) - Example of calculation of the
            standard deviation s[AMS] of the AMS at zero
            and span level
    Annex G (informative) - Example of using the calibration
            function and testing the variability and validity of
            the calibration function in the AST
    Annex H (informative) - Implementation of QAL1
    Annex I (normative) - k[v] and t[0,95; N-1] values
    Annex J (informative) - Significant technical changes
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes procedures for establishing quality assurance levels (QAL) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters.

    Scope - (Show below) - (Hide below)

    This European Standard specifies procedures for establishing quality assurance levels (QAL) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters. This European Standard specifies: a procedure (QAL2) to calibrate the AMS and determine the variability of the measured values obtained by it, so as to demonstrate the suitability of the AMS for its application, following its installation; a procedure (QAL3) to maintain and demonstrate the required quality of the measurement results during the normal operation of an AMS, by checking that the zero and span characteristics are consistent with those determined during QAL1; a procedure for the annual surveillance tests (AST) of the AMS in order to evaluate (i) that it functions correctly and its performance remains valid and (ii) that its calibration function and variability remain as previously determined. This European Standard is designed to be used after the AMS has been certified in accordance with the series of European Standards EN15267 .

    General Product Information - (Show below) - (Hide below)

    Committee EH/2/1
    Development Note Supersedes 01/562616 DC. (12/2004) Supersedes 12/30259213 DC. (12/2014)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 6739:2009 Code of practice for instrumentation in process control systems: installation design and practice
    08/30136724 DC : DRAFT MAY 2008 BS 6739 - CODE OF PRACTICE FOR INSTRUMENTATION IN PROCESS CONTROL SYSTEMS - INSTALLATION DESIGN AND PRACTICE
    EEMUA 175 : 2013 EEMUA CODE OF PRACTICE: CALIBRATION AND VALIDATION OF PROCESS ANALYSERS

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
    EN 15267-3:2007 Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources
    ISO 14956:2002 Air quality Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
    EN 15267-2:2009 Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process
    ISO 11095:1996 Linear calibration using reference materials
    EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
    EN 13284-1:2017 Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
    EN 13284-2:2017 Stationary source emissions - Determination of low range mass concentration of dust - Part 2: Quality assurance of automated measuring systems
    EN 15058:2017 Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
    EN ISO 14956 : 2002 AIR QUALITY - EVALUATION OF THE SUITABILITY OF A MEASUREMENT PROCEDURE BY COMPARISON WITH A REQUIRED MEASUREMENT UNCERTAINTY
    EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    ISO 3534-1:2006 Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective