• BS EN 14791:2017

    Current The latest, up-to-date edition.

    Stationary source emissions. Determination of mass concentration of sulphur oxides. Standard reference method

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-03-2017

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols and abbreviations
    5 Principle
    6 Description of measuring system
    7 Performance characteristics of the SRM
    8 Field operation
    9 Analytical procedure
    10 Expression of results
    11 Equivalence of Thorin and ion chromatography methods
    12 Equivalence of an alternative method
    13 Measurement report
    Annex A (informative) - Validation of the method in the field
    Annex B (informative) - Examples of absorbers
    Annex C (informative) - Example of assessment of compliance of
            standard reference method for SO[2] with requirements on
            emission measurements
    Annex D (informative) - Type of sampling equipment
    Annex E (informative) - Example of comparison of repeatability and
            trueness of Thorin Method and Ion Chromatography Method
    Annex F (informative) - Calculation of the uncertainty associated
            with a concentration expressed on dry gas and at an oxygen
            reference concentration
    Annex G (informative) - Significant technical changes
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines the standard reference method (SRM) for the determination of the sulphuric oxide SO[2] in flue gases emitted to the atmosphere from ducts and stacks.

    Scope - (Show below) - (Hide below)

    This European Standard specifies the standard reference method (SRM) for the determination of the sulphuric oxide SO 2 in flue gases emitted to the atmosphere from ducts and stacks. It is based on a sampling system and two analytical principles: ion chromatography and the Thorin method. This European Standard specifies the performance characteristics to be determined and the performance criteria to be fulfilled by measuring systems based on the measurement method. It applies to periodic monitoring and to the calibration or control of automatic measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes. This European Standard specifies criteria for demonstration of equivalence of an alternative method to the SRM by application of EN14793:2017 . This European Standard has been validated during field tests on waste incineration, co-incineration and large combustion installations. It has been validated for sampling periods of 30min in the range of 0,5mg/m 3 to 2000mg/m 3 of SO 2 for an ion-chromatography variant and 5mg/m 3 to 2000mg/m 3 of SO 2 for the Thorin method according to emission limit values laid down in the Directive 2010/75/EU . NOTE1 Emission limit values for SO 2 laid down in the Directive 2010/75/EU are in the range of 30mg/m 3 to 800mg/m 3. The emission limit values of EU Directives are expressed in units of mg/m 3 of SO 2 on dry basis and at standard conditions of 273K and 101,3kPa. NOTE2 The characteristics of installations, the conditions during field tests and the values of repeatability and reproducibility in the field are given in AnnexA.

    General Product Information - (Show below) - (Hide below)

    Committee EH/2/1
    Development Note Supersedes 03/312902 DC. (02/2006) Supersedes 14/30293544 DC. (03/2017)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    CEN/TS 15675:2007 Air quality - Measurement of stationary source emissions - Application of EN ISO/IEC 17025:2005 to periodic measurements
    ISO 14956:2002 Air quality Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
    ISO 5725-6:1994 Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values
    EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
    PREN 13284-1 : DRAFT 2015 STATIONARY SOURCE EMISSIONS - DETERMINATION OF LOW RANGE MASS CONCENTRATION OF DUST - PART 1: MANUAL GRAVIMETRIC METHOD
    EN ISO 14956 : 2002 AIR QUALITY - EVALUATION OF THE SUITABILITY OF A MEASUREMENT PROCEDURE BY COMPARISON WITH A REQUIRED MEASUREMENT UNCERTAINTY
    ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    EN 14793:2017 Stationary source emissions - Demonstration of equivalence of an alternative method with a reference method