• BS EN 15091:2013

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Sanitary tapware. Electronic opening and closing sanitary tapware

    Available format(s):  Hardcopy, PDF

    Superseded date:  22-03-2024

    Language(s):  English

    Published date:  31-12-2013

    Publisher:  British Standards Institution

    Add To Cart

    Scope - (Show below) - (Hide below)

    The purpose of this European Standard is to define requirements for marking, identification, leaktightness, electrical and operational safety and mechanical resistance for sanitary tapware with opening and closing controlled electronically. The conditions of use for the supply system type are specified in Table 2: Table 2 — Conditions of use Water supply system Limits of use Recommended limits of operation Tapware with normally open or normally closed (monostable) solenoid valves Tapware with latching (bistable) solenoid valves Tapware with normally open or normally closed (monostable) solenoid valves Tapware with latching (bistable) solenoid valves Type 1 (see Figure 1) Minimum dynamic pressure 0,05 MPa (0,5 bar) 0,05 MPa (0,5 bar) (0,1 to 0,5) MPa [(1 to 5) bar] (0,1 to 0,5) MPa [(1 to 5) bar] Maximum static pressure 1 MPa (10 bar) 1 MPa (10 bar) 1 MPa (10 bar) 0.8 MPa (8 bar) Type 2 a (see Figure 2) Minimum dynamic pressure 0,01 MPa (0,1 bar) 0,01 MPa (0,1 bar) (0,01 to 0,2) MPa [(0,1 to 2) bar] (0,01 to 0,2) MPa [(0,1 to 2) bar] Maximum static pressure 1 MPa (10 bar) 1 MPa (10 bar) 0.8 MPa (8 bar) 0.6 MPa (6 bar) Temperature of the water ≤ 75 °C ≤ 75 °C ≤ 65 °C ≤ 65 °C a For Type 2, the manufacturer is to declare the minimum operating pressure at which opening, closing and the specified flow rate can be obtained. There is usually no acoustic classification for tapware used in supply systems of Type 2 and no specifications governing the level of noise emissions from these water installations. If supply pressures are such that excessive noise is generated it is recommended that pressure or flow regulators are fitted in the system. Or where practicable, tapware conforming to the appropriate acoustic classification are used. Annex B lists possible consequences of using a product outside its recommended operating range. A vented domestic hot water and cold water supply system incorporating gravity hot water, mains cold water and alternative gravity cold water supply to sanitary appliances.

    General Product Information - (Show below) - (Hide below)

    Committee B/504
    Development Note Supersedes 04/30126825 DC (02/2007) Supersedes 12/30260007 DC. (01/2014)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 35:2014 PEDESTAL AND WALL-HUNG BIDETS WITH OVER-RIM SUPPLY - CONNECTING DIMENSIONS
    EN 61000-6-1:2007 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments
    EN 246:2003 Sanitary tapware - General specifications for flow rate regulators
    EN 61000-6-3:2007/A1:2011/AC:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010)
    EN 36:1998 Wall-hung bidets with overrim supply - Connecting dimensions
    EN 13618:2016 Flexible hose assemblies in drinking water installations - Functional requirements and test methods
    IEC 61000-6-1 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS
    EN 13407:2015 WALL-HUNG URINALS - FUNCTIONAL REQUIREMENTS AND TEST METHODS
    EN 695:2005 Kitchen sinks - Connecting dimensions
    EN 12541:2002 Sanitary tapware - Pressure flushing valves and automatic closing urinal valves PN 10
    EN 31:2011+A1:2014 Wash basins - Connecting dimensions
    EN ISO 228-1:2003 Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000)
    IEC 61000-6-3:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
    EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
    EN 60730-2-8:2002/A1:2003 AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-8: PARTICULAR REQUIREMENTS FOR ELECTRICALLY OPERATED WIRE VALVES, INCLUDING MECHANICAL REQUIREMENTS
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60730-2-8:2000+AMD1:2002+AMD2:2015 CSV Automatic electrical controls for household and similar use - Part 2-8: Particular requirements for electrically operated watervalves, including mechanical requirements
    ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
    IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
    EN 13959:2004 Anti-pollution check valves - DN 6 to DN 250 inclusive family E, type A, B, C and D
    EN 60335-1:2012/A13:2017 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    ISO 228-1:2000 Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation
    EN 248:2002 Sanitary tapware - General specification for electrodeposited coatings of Ni-Cr
    EN 60730-1:2016 Automatic electrical controls - Part 1: General requirements
    IEC 60730-1:2013+AMD1:2015 CSV Automatic electrical controls - Part 1: General requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective