• BS EN 15549:2008

    Current The latest, up-to-date edition.

    Air quality. Standard method for the measurement of the concentration of benzo(a)pyrene in ambient air

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  30-04-2008

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols and abbreviations
    5 Principle of the method
    6 Requirements
    7 Reagents and gases
    8 Apparatus
    9 Sampling
    10 Sample preparation
    11 Analysis
    12 Quantification
    13 Quality control
    14 Determination of measurement uncertainty
    15 Interferences
    16 Reporting of results
    Annex A (informative) - Sampling systems
    Annex B (informative) - Extraction methods (examples of
                            experimental conditions)
    Annex C (informative) - Example for clean-up procedure
    Annex D (informative) - Parameters for analysis (examples)
    Annex E (informative) - Assessment of performance indicators
                            and uncertainty contributions
    Annex F (informative) - Results of laboratory and field tests
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines a measurement method for the determination of particulate benzo[a]pyrene (BaP) in ambient air, which can be used in the framework of the Council Directive 96/62/EC and the Directive 2004/107/EC. It also defines performance characteristics and performance criteria for the measurement method when it is used as a reference method.

    Scope - (Show below) - (Hide below)

    This document specifies a measurement method for the determination of particulate benzo[a]pyrene (BaP) in ambient air, which can be used in the framework of the Council Directive 96/62/EC [1] and the Directive 2004/107/EC [2]. This document specifies performance characteristics and performance criteria to which the method should comply when it is used as a reference method. The performance characteristics of the measurement method are based on a sampling period of 24 h. This document describes a measurement method which comprises sampling of BaP as part of the PM10 particles, sample extraction and analysis by high performance liquid chromatography (HPLC) with fluorescence detector (FLD) or by gas chromatography with mass spectrometric detection (GC/MS). The method is applicable for the measurement of BaP in the concentration range from approx. 0,04 ng/m3 to approximately 20 ng/m3. The lower limit of the applicable range depends on the noise level of the detector and the variability of the laboratory filter blank. NOTE If the BaP concentration exceeds the calibration range the extract can be diluted.

    General Product Information - (Show below) - (Hide below)

    Committee EH/2/3
    Development Note Supersedes 06/30142044 DC. (04/2008)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
    EN 13274-7:2008 Respiratory protective devices - Methods of test - Part 7: Determination of particle filter penetration
    ISO 12884:2000 Ambient air Determination of total (gas and particle-phase) polycyclic aromatic hydrocarbons Collection on sorbent-backed filters with gas chromatographic/mass spectrometric analyses
    EN 14902:2005/AC:2006 AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF PB, CD, AS AND NI IN THE PM10 FRACTION OF SUSPENDED PARTICULATE MATTER
    EN ISO 20988:2007 Air quality - Guidelines for estimating measurement uncertainty (ISO 20988:2007)
    ISO 16362:2005 Ambient air — Determination of particle-phase polycyclic aromatic hydrocarbons by high performance liquid chromatography
    ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
    ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
    EN 1822-1:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking
    ISO 20988:2007 Air quality Guidelines for estimating measurement uncertainty
    EN 12341:2014 Ambient air - Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective