• BS EN 60601-2-26:2015

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Medical electrical equipment Particular requirements for the basic safety and essential performance of electroencephalographs

    Available format(s):  Hardcopy, PDF

    Superseded date:  05-11-2021

    Language(s):  English

    Published date:  30-06-2015

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    201.1 Scope, object and related standards
    201.2 Normative references
    201.3 Terms and definitions
    201.4 General requirements
    201.5 General requirements for testing of
           ME EQUIPMENT
    201.6 Classification of ME EQUIPMENT and
           ME SYSTEMS
    201.7 ME EQUIPMENT identification, marking
           and documents
    201.8 Protection against electrical HAZARDS
           from ME EQUIPMENT
    201.9 Protection against MECHANICAL HAZARDS
           of ME EQUIPMENT and ME SYSTEMS
    201.10 Protection against unwanted and excessive
           radiation HAZARDS
    201.11 Protection against excessive temperatures
           and other HAZARDS
    201.12 Accuracy of controls and instruments and
           protection against hazardous outputs
    201.13 HAZARDOUS SITUATIONS and fault
           Conditions
    201.14 PROGRAMMABLE ELECTRICAL MEDICAL
           SYSTEMS (PEMS)
    201.15 Construction of ME EQUIPMENT
    201.16 ME SYSTEMS
    201.17 ELECTROMAGNETIC COMPATIBILITY of
           ME EQUIPMENT and ME SYSTEMS
    202 ELECTROMAGNETIC COMPATIBILITY - Requirements
        and tests
    Annexes
    Annex AA (informative) - Particular guidance and rationale
    Index of defined terms used in this particular standard
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications
    Annex ZZ (informative) - Coverage of Essential
             Requirements of EU Directives

    Abstract - (Show below) - (Hide below)

    Pertains to BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTROENCEPHALOGRAPHS (EEG) as defined in 201.3.63, hereafter referred to as ME EQUIPMENT.

    Scope - (Show below) - (Hide below)

    IEC 60601-2-26:2012 standard applies to basic safety and essential performance of electroencephalographs used in a clinical environment (e.g., hospital, physician\'s office, etc.). This standard does not cover requirements for other equipment used in electroencephalography. This third edition cancels and replaces the second edition of IEC 60601-2-26 published in 2003. The aim of this third edition is to bring this particular standard up to date with reference to the third edition of the general standard IEC 60601-1:2005 Edition 3, through reformatting and technical changes.

    General Product Information - (Show below) - (Hide below)

    Committee CH/62/4
    Development Note Supersedes 01/564186 DC (08/2003) 2003 Edition remains active & will be withdrawn on 14/04/2018. Supersedes 09/30172488 DC. (06/2015) Supersedes BS 5724-2.126(1995). (08/2015)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    EN 60601-2-27:2014 Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment
    IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    IEC 60601-2-27:2011 Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective