• BS EN 62439-6:2010

    Current The latest, up-to-date edition.

    Industrial communication networks. High availability automation networks Distributed redundancy protocol (DRP)

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  30-06-2010

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms, definitions, abbreviations, acronyms,
      and conventions
    4 Overview
    5 DRP communications
    6 DRP class specification
    7 DRP attributes
    8 DRP services
    9 DRP protocol specification
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Pertains to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology.

    Scope - (Show below) - (Hide below)

    IEC 62439-6:2010 is applicable to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology. It specifies a recovery protocol based on a ring topology, designed to react deterministically on a single failure of an inter-switch link or switch in the network. Each switch has equal management role in the network. Double rings are supported. It cancels and replaces IEC 62439 published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to IEC 62439 (2008):
    - adding a calculation method for RSTP (rapid spanning tree protocol, IEEE 802.1Q),
    - adding two new redundancy protocols: HSR (High-availability Seamless Redundancy) and DRP (Distributed Redundancy Protocol),
    - moving former Clauses 1 to 4 (introduction, definitions, general aspects) and the Annexes (taxonomy, availability calculation) to IEC 62439-1, which serves now as a base for the other documents,
    - moving Clause 5 (MRP) to IEC 62439-2 with minor editorial changes,
    - moving Clause 6 (PRP) was to IEC 62439-3 with minor editorial changes,
    - moving Clause 7 (CRP) was to IEC 62439-4 with minor editorial changes, and
    - moving Clause 8 (BRP) was to IEC 62439-5 with minor editorial changes,
    - adding a method to calculate the maximum recovery time of RSTP in a restricted configuration (ring) to IEC 62439-1 as Clause 8,
    - adding specifications of the HSR (High-availability Seamless Redundancy) protocol, which shares the principles of PRP to IEC 62439-3 as Clause 5, and
    - introducing the DRP protocol as IEC 62439-6.

    This publication is to be read in conjunction with IEC 62439-1:2010.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/65/3
    Development Note Together with BS EN 62439-1, BS EN 62439-2, BS EN 62439-3, BS EN 62439-4 and BS EN 62439-5, it supersedes BS EN 62439. (06/2010)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 62439-1:2010/A2:2017 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 1: GENERAL CONCEPTS AND CALCULATION METHODS (IEC 62439-1:2010/A2:2016)
    IEC 62439-3:2016 Industrial communication networks - High availability automation networks - Part 3: Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR)
    IEC 62439-4:2010 Industrial communication networks - High availability automation networks - Part 4: Cross-network Redundancy Protocol (CRP)
    ISO/IEC 8802-3:2000 Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications
    IEEE 802.1Q-2014 IEEE Standard for Local and metropolitan area networks--Bridges and Bridged Networks
    IEEE 802.1D-2004 IEEE Standard for Local and metropolitan area networks: Media Access Control (MAC) Bridges
    IEC 62439-5:2016 Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP)
    IEC 61588:2009 Precision clock synchronization protocol for networked measurement and control systems
    IEC 62439-1:2010+AMD1:2012+AMD2:2016 CSV Industrial communication networks - High availability automation networks - Part 1: General concepts and calculation methods
    IEEE 1588-2008 REDLINE IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems
    ISO/IEC TR 8802-1:2001 Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 1: Overview of Local Area Network Standards
    IEC 62439-2:2016 Industrial communication networks - High availability automation networks - Part 2: Media Redundancy Protocol (MRP)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective