• BS EN ISO 80369-3:2016

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Small-bore connectors for liquids and gases in healthcare applications Connectors for enteral applications

    Available format(s): 

    Withdrawn date:  24-03-2023

    Language(s): 

    Published date:  31-08-2016

    Publisher:  British Standards Institution

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General requirements
    5 Dimensional requirements for ENTERAL
      SMALL-BORE CONNECTORS
    6 Performance requirements
    Annex A (informative) - Rationale and guidance
    Annex B (normative) - ENTERAL SMALL-BORE
            CONNECTORS
    Annex C (normative) - Reference CONNECTORS
    Annex D (informative) - Assessment of MEDICAL
            DEVICES and their attributes with
            CONNECTIONS within this APPLICATION
    Annex E (informative) - Summary of the usability
            requirements for SMALL-BORE
            CONNECTORS for ENTERAL applications
    Annex F (informative) - Summary of SMALL-BORE
            CONNECTOR criteria and requirements for
            ENTERAL APPLICATIONS
    Annex G (informative) - Summary of assessment of
            the design of the CONNECTORS for ENTERAL
            APPLICATIONS
    Annex H (informative) - Reference to the essential
            principles
    Annex I (informative) - Terminology - Alphabetized
            index of defined terms
    Bibliography
    Annex ZA (informative) - Relationship between this
             document and the Essential Requirements of
             EU Directive 93/42/EEC

    Abstract - (Show below) - (Hide below)

    Defines the dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections on enteral medical devices and accessories.

    Scope - (Show below) - (Hide below)

    This part of ISO80369 specifies the dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections on enteral medical devices and accessories. NOTE1 Enteral medical devices include enteral feeding sets, enteral drainage sets, enteral syringes, and patient interface devices including access ports. This part of ISO80369 does not specify the dimensions and requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular International Standards for specific medical devices or accessories. This part of ISO80369 does not specify requirements for small-bore connectors that are used for the following: gastric suction-only medical devices; oral-only medical devices; EXAMPLE An oral tip syringe that is not intended to connect to another medical device. It is intended to administer directly to the patient’s mouth. pressurizing and depressurizing the retention mechanism (e.g. balloon) used to hold invasive enteral medical devices in place; medical devices for rectal drainage, rectal administration of medicines or fluid, and any other rectal access medical device; gastrointestinal endoscopy equipment; skin level gastrostomy medical devices. NOTE2 Manufacturers are encouraged to incorporate the small-bore connectors specified in this part of ISO80369 into enteral medical devices or accessories, even if currently not required by the relevant particular medical device standards. It is expected that when the relevant particular medical device standards are revised, requirements for small-bore connectors, as specified in ISO80369, will be included.

    General Product Information - (Show below) - (Hide below)

    Committee CH/210/5
    Development Note Supersedes 13/30285694 DC. (08/2016)
    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 1618 : 1997 CATHETERS OTHER THAN INTRAVASCULAR CATHETERS - TEST METHODS FOR COMMON PROPERTIES
    ISO 80369-20:2015 Small-bore connectors for liquids and gases in healthcare applications Part 20: Common test methods
    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    ISO 5356-1:2015 Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets
    ISO 10241-2:2012 Terminological entries in standards — Part 2: Adoption of standardized terminological entries
    ISO 5356-2:2012 Anaesthetic and respiratory equipment — Conical connectors — Part 2: Screw-threaded weight-bearing connectors
    IEC 62366:2007+AMD1:2014 CSV Medical devices - Application of usability engineering to medical devices
    ISO 7886-1:2017 Sterile hypodermic syringes for single use — Part 1: Syringes for manual use
    CR 13825:2000 Luer connectors - A report to CEN chef from the CEN forum task group "Luer fittings"
    ISO 8185:2007 Respiratory tract humidifiers for medical use Particular requirements for respiratory humidification systems
    ISO 80369-6:2016 Small bore connectors for liquids and gases in healthcare applications — Part 6: Connectors for neuraxial applications
    ASTM D 790 : 2017 : REDLINE Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
    ISO 80369-1:2010 Small-bore connectors for liquids and gases in healthcare applications Part 1: General requirements
    EN 1615 : 2000 ENTERAL FEEDING CATHETERS AND ENTERAL GIVING SETS FOR SINGLE USE AND THEIR CONNECTORS - DESIGN AND TESTING
    ISO 10241-1:2011 Terminological entries in standards — Part 1: General requirements and examples of presentation
    ISO 14971:2007 Medical devices Application of risk management to medical devices
    EN 13544-2:2002+A1:2009 Respiratory therapy equipment - Part 2: Tubing and connectors
    ASTM D 638 : 2014 : REDLINE Standard Test Method for Tensile Properties of Plastics
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective