• BS ISO 23830:2008

    Current The latest, up-to-date edition.

    Surface chemical analysis. Secondary-ion mass spectrometry. Repeatability and constancy of the relative-intensity scale in static secondary-ion mass spectrometry

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-12-2008

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Symbols and abbreviations
    3 Outline of method
    4 Method for confirming the repeatability and constancy
      of the intensity scale
      4.1 Obtaining the reference sample
      4.2 Preparation for mounting the sample
      4.3 Mounting the sample
      4.4 Choosing the spectrometer settings for which intensity
          stability is to be determined
      4.5 Operating the instrument
      4.6 Measurements of the intensity and its repeatability
      4.7 Calculating the intensity repeatability
      4.8 Procedure for the regular determination of the constancy
          of the relative-intensity scale
      4.9 Next calibration
    Annex A (informative) - Example of suitable operating conditions
                            for static SIMS
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes a method for confirming the repeatability and constancy of the positive-ion relative-intensity scale of static secondary-ion mass spectrometers, for general analytical purposes.

    Scope - (Show below) - (Hide below)

    This International Standard specifies a method for confirming the repeatability and constancy of the positive-ion relative-intensity scale of static secondary-ion mass spectrometers, for general analytical purposes. It is only applicable to instruments that incorporate an electron gun for charge neutralization. It is not intended to be a calibration of the intensity/mass response function. That calibration may be made by the instrument manufacturer or another organization. The present method provides data to confirm the constancy of relative intensities with instrument usage. Guidance is given on some of the instrument settings that may affect this constancy.

    General Product Information - (Show below) - (Hide below)

    Committee CII/60
    Development Note Supersedes 07/30138812 DC. (12/2008)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 7873:1993 Control charts for arithmetic average with warning limits
    ISO 24236:2005 Surface chemical analysis Auger electron spectroscopy Repeatability and constancy of intensity scale
    ISO 7870-1:2014 Control charts Part 1: General guidelines
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective