This International Standard specifies the performance data that are necessary to state and applicable test methods for different types of compressed air dryers. It is applicable to compressed air dryers working with an effective (gauge) pressure of more than 50kPa (0,5 bar), but less than or equal to 1600kPa (16 bar) and include the following:
NOTE A description of the principles of operation of the dryers within the Scope of this International Standard is given in AnnexA.
This International Standard identifies test methods for measuring dryer parameters that include the following:
-
pressure dew point;
-
flow rate;
-
pressure drop;
-
compressed-air loss;
-
power consumption;
-
noise emission.
This International Standard also provides partial-load tests for determining the performance of energy saving devices or measures.
The mounting, operating and loading conditions of dryers for the measurement of noise are given in AnnexC.
This International Standard is not applicable to the following types of dryers or drying processes: