• PD IEC/TR 60977:2008

    Current The latest, up-to-date edition.

    Medical electrical equipment. Medical electron accelerators. Guidelines for functional performance characteristics

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  09-07-2008

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 Scope
    2 Normative references
    3 General, type tests
      3.1 Format of Annex A of the disclosure standard with
          suggested functional performance values
      3.2 Rationale for functional performance values suggested
          by the Working Group
          3.2.1 Introduction
          3.2.2 IEC 60976, Clause 6
          3.2.3 Suggested functional performance values
    4 Acceptance tests
      4.1 General
      4.2 Summary of suggested test methods for MEDICAL
          ELECTRON ACCELERATOR acceptance
      4.3 Acceptance test conditions
      4.4 Suggested equipment for acceptance tests and for
          subsequent periodic tests
          4.4.1 Introduction
          4.4.2 Item description
    5 Periodic tests
      5.1 Introduction
      5.2 Suggested set of periodic test methods and test
          conditions
      5.3 Suggested frequency for periodic tests during working
          life of the ELECTRON ACCELERATOR
    Bibliography

    Abstract - (Show below) - (Hide below)

    Applies to medical ELECTRON ACCELERATORS when used, for therapy purposes, in human medical practice.

    Scope - (Show below) - (Hide below)

    IEC/TR 60977:2008 applies to medical electron accelerators when used, for therapy purposes, in human medical practice. This technical report applies to medical electron accelerators which deliver a radiation beam of either X-radiation or electron radiation with nominal energies in the range 1 MeV to 50 MeV at maximum absorbed dose rates between 0,001 Gy s -1 and 1 Gy s -1 at 1 m from the radiation source and at normal treatment distances between 50 cm and 200 cm from the radiation source. This second edition cancels and replaces the first edition published in 1989 and its Amendment 1 (2000). It constitutes a technical revision. This second edition likewise follows on the issue of a second edition to the disclosure standard IEC 60976 in 2007. It includes the addition of performance guidelines relating to several relatively new technologies introduced within the last few years, including dynamic beam delivery techniques, such as moving beam radiotherapy, intensity modulated radiation therapy (IMRT), image guided radiotherapy (IGRT), and programmable wedge fields (PWF). Also included are stereotactic radiotherapy (SRT)/stereotactic radiosurgery (SRS) and the use of certain electronic imaging devices (EIDs).

    General Product Information - (Show below) - (Hide below)

    Committee CH/62/3
    Development Note Supersedes BS 5724-3.1:SUPP1(1990). (09/2008)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    IEC 60976:2007 Medical electrical equipment - Medical electron accelerators - Functional performance characteristics
    IEC 60601-2-1:2009+AMD1:2014 CSV Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV