• CEI EN 60099-9 : 2015

    Current The latest, up-to-date edition.

    SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2015

    Publisher:  Comitato Elettrotecnico Italiano

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Typical HVDC converter station schemes, arrester
       types, locations and operating voltage
    5 Identification and classification
    6 Service conditions
    7 Requirements
    8 General testing procedure
    9 Type tests (design tests)
    10 Routine tests and acceptance test
    11 Test requirements on different types of arresters
    Annex A (normative) - Test to verify thermal equivalency
            between complete arrester and arrester section
    Annex B (normative) - Determination of the start temperature
            in the thermal recovery test
    Annex C (normative) - Mechanical considerations
    Annex D (informative) - Different circuit configurations
    Bibliography
    Annex ZA (normative) - Normative references to international
             publications with their corresponding
             European publications

    Abstract - (Show below) - (Hide below)

    Pertains to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1100 kV.

    General Product Information - (Show below) - (Hide below)

    Committee CT 37
    Development Note Classificazione CEI 37-18. (03/2015)
    Document Type Standard
    Publisher Comitato Elettrotecnico Italiano
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
    ISO 4892-1:2016 Plastics Methods of exposure to laboratory light sources Part 1: General guidance
    IEC 60143-2:2012 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
    IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
    IEC 60143-1:2015 Series capacitors for power systems - Part 1: General
    IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
    IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
    IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
    EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60068-2-11:1981 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
    EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
    IEC TS 60071-5:2002 Insulation co-ordination - Part 5: Procedures for high-voltage direct current (HVDC) converter stations
    EN 60060-2:2011 High-voltage test techniques - Part 2: Measuring systems
    EN 60143-2:2013 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
    ISO 4892-3:2016 Plastics Methods of exposure to laboratory light sources Part 3: Fluorescent UV lamps
    EN 60068-2-17:1994 Environmental testing - Part 2: Tests - Test Q: Sealing
    IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
    IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    IEC 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
    IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
    CISPR TR 18-2:2017 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits
    IEC 60633:1998+AMD1:2009+AMD2:2015 CSV Terminology for high-voltage direct current (HVDC) transmission
    IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
    ISO 4892-2:2013 Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps
    EN 60071-2:1997 Insulation co-ordination - Part 2: Application guide
    EN 60068-2-11:1999 Environmental testing - Part 2: Tests - Test Ka: Salt mist
    EN 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
    IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
    EN 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
    EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
    EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
    IEC TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems
    EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective