• CISPR 16-1-1 REDLINE : 4ED 2015

    Current The latest, up-to-date edition.

    SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  International Electrotechnical Committee

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Quasi-peak measuring receivers for the
      frequency range 9 kHz to 1000 MHz
    5 Measuring receivers with peak detector for
      the frequency range 9 kHz to 18 GHz
    6 Measuring receivers with average detector
      for the frequency range 9 kHz to 18 GHz
    7 Measuring receivers with rms-average
      detector for the frequency range 9 kHz to
      18 GHz
    8 Measuring receivers for the frequency
      range 1 GHz to 18 GHz with amplitude
      probability distribution (APD) measuring
      function
    9 Disturbance analyzers
    Annex A (normative) - Determination of response
            to repeated pulses of quasi-peak and
            rms-average measuring receivers
    Annex B (normative) - Determination of pulse
            generator spectrum
    Annex C (normative) - Accurate measurements
            of the output of nanosecond pulse
            generators
    Annex D (normative) - Influence of the quasi-peak
            measuring receiver characteristics
            on its pulse response
    Annex E (normative) - Response of average and
            peak measuring receivers
    Annex F (normative) - Performance check of the
            exceptions from the definitions of a
            click according to 4.2.3 of CISPR 14-1:2005
    Annex G (informative) - Rationale for the
            specifications of the APD measuring function
    Annex H (informative) - Characteristics of a quasi-peak
            measuring receiver
    Annex I (informative) - Example of EMI receiver
            and swept spectrum analyzer architecture
    Annex J (normative) - Requirements when using an
            external preamplifier with a measuring receiver
    Annex K (normative) - Calibration requirements for
            measuring receivers
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz.

    General Product Information - (Show below) - (Hide below)

    Committee CIS/A
    Development Note Stability date: 2018. (09/2015)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    CISPR 14-1:2016 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
    CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
    CISPR 16-2-2:2010 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power
    CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
    CISPR 16-1-3:2004+AMD1:2016 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power
    CISPR 16-2-1:2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
    CISPR 15:2013+AMD1:2015 CSV Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
    CISPR 16-1-5:2014+AMD1:2016 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
    CISPR TR 16-4-3:2004+AMD1:2006 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-3: Uncertainties, statistics and limit modelling - Statistical considerations in the determination of EMC compliance of mass-produced products
    CISPR 32:2015 RLV Electromagnetic compatibility of multimedia equipment - Emission requirements
    CISPR 16-2-4:2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-4: Methods of measurement of disturbances and immunity - Immunity measurements
    CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
    CISPR TR 16-4-1:2009 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests
    CISPR 25:2016 Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
    ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
    CISPR 16-2-3:2016 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
    CISPR TR 16-4-4:2007 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-4: Uncertainties, statistics and limit modelling - Statistics of complaints and a model for the calculation of limits for the protection of radio services
    CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
    EN 50065-1:2011 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective