• CISPR TR 18-1:2010

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Radio interference characteristics of overhead power lines and high-voltage equipment - Part 1: Description of phenomena

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  31-12-2021

    Language(s):  English

    Published date:  24-06-2010

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Radio noise from HV AC overhead power
      lines
    5 Effects of corona from conductors
    6 Radio noise levels due to insulators,
      hardware and substation equipment
      (excluding bad contacts)
    7 Sparking due to bad contacts
    8 Radio noise from HVDC overhead power
      lines
    9 Figures
    Annex A (informative) - Calculation of the
            voltage gradient at the surface of a
            conductor of an overhead line
    Annex B (informative) - Catalogue of profiles
            of radio noise field due to conductor
            corona for certain types of power line
    Annex C (informative) - Summary of the catalogue
            of radio noise profiles according to
            the recommendations of the CISPR
    Bibliography

    Abstract - (Show below) - (Hide below)

    CISPR 18-1:2010(E), which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception. The scope of this publication includes the causes, measurement and effects of radio interference, design aspects in relation to this interference, methods and examples for establishing limits and prediction of tolerable levels of interference from high voltage overhead power lines and associated equipment, to the reception of radio broadcast services.The frequency range covered is 0,15 MHz to 300 MHz. Radio frequency interference caused by the pantograph of overhead railway traction systems is not considered in this technical report. This second edition cancels and replaces the first edition published in 1982. It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
    - while the first edition of CISPR 18-1 only covered the direct distance D0 for the establishment of standard profiles for the lateral radio noise field emanating from HV overhead power lines,
    - this second edition now also allows for use of the lateral distance y0 for these purposes. This way it allows for the establishment of standard profiles for the lateral radio noise field also from modern HV overhead power line constructions with tall suspension towers.

    General Product Information - (Show below) - (Hide below)

    Committee CISPR/CIS/B
    Development Note Supersedes CISPR 18-1. (06/2010) Stability Date: 2020. (10/2017)
    Document Type Technical Report
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 61000-6-5:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR EQUIPMENT USED IN POWER STATION AND SUBSTATION ENVIRONMENT
    CAN/CSA-IEC 61000-6-5:18 Electromagnetic compatibility (EMC) — Part 6-5: Generic standards — Immunity for equipment used in power station and substation environment (Adopted IEC 61000-6-5:2015, first edition, 2015-08) | Compatibilité électromagnétique (CEM) — Partie 6-5 : Normes génériques — Immunité pour les équipements utilisés dans les environnements de centrales électriques et de postes (norme IEC 61000-6-5:2015 adoptée, première édition, 2015-08)
    CISPR TR 18-3:2017 RLV Radio interference characteristics of overhead power lines and high-voltage equipment - Part 3: Code of practice for minimizing the generation of radio noise
    EN 61000-6-5:2015/AC:2018-01 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR EQUIPMENT USED IN POWER STATION AND SUBSTATION ENVIRONMENT (IEC 61000-6-5:2015/COR1:2017)
    CSA C108.3.1:1984 : R2009 LIMITS AND MEASUREMENT METHODS OF ELECTROMAGNETIC NOISE FROM AC POWER SYSTEMS, 0.15 - 30 MHZ
    PD CISPR/TR 18-3:2017 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 3: Code of practice for minimizing the generation of radio noise
    CISPR TR 18-3:2017 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 3: Code of practice for minimizing the generation of radio noise
    CSA C108.3.1 : 1984 : R2005 LIMITS AND MEASUREMENT METHODS OF ELECTROMAGNETIC NOISE FROM AC POWER SYSTEMS, 0.15 - 30 MHZ
    UNE-EN 61000-6-5:2016 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment
    PD CISPR/TR 18-2:2017 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits
    BS EN 61000-6-5:2015 Electromagnetic compatibility (EMC) Generic standards. Immunity for equipment used in power station and substation environment
    CSA C108.3.1 : 1984 : R2014 LIMITS AND MEASUREMENT METHODS OF ELECTROMAGNETIC NOISE FROM AC POWER SYSTEMS, 0.15 - 30 MHZ
    CISPR TR 18-2:2017 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits
    CISPR TR 18-3 REDLINE : 3ED 2017 RADIO INTERFERENCE CHARACTERISTICS OF OVERHEAD POWER LINES AND HIGH-VOLTAGE EQUIPMENT - PART 3: CODE OF PRACTICE FOR MINIMIZING THE GENERATION OF RADIO NOISE

    Standards Referencing This Book - (Show below) - (Hide below)

    CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
    IEC TR 62543:2011+AMD1:2013 CSV High-voltage direct current (HVDC) power transmission using voltage sourced converters (VSC)
    ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
    CISPR TR 18-3:2017 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 3: Code of practice for minimizing the generation of radio noise
    CISPR TR 18-2:2017 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective