• CSA C22.4 PACKAGE : 2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    CONSISTS OF C22.4 NO. 1-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE AND C22.4 NO. 2-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE - SAFETY MANAGEMENT SYSTEM REQUIREMENTS

    Available format(s):  Hardcopy, PDF

    Superseded date:  14-07-2021

    Language(s):  English

    Published date:  01-01-2013

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    C22.4 No. 1-09 - Objective-based industrial electrical code
    Preface
    0 Object
    1 Scope
    2 Reference publications
    3 Definitions
    4 Protection for safety
    5 Design
    6 Selection of electrical equipment
    7 Erection and verification of electrical installations
    8 Operation and maintenance
    Annexes
    A (normative) - Electrical equipment selection criteria
    B (informative) - Technical references
    C22.4 No. 2-09 - Objective-based industrial electrical code -
                     Safety management system requirements
    Preface
    0 Object
    1 Scope
    2 Reference publications
    3 Definitions
    4 Safety management system for the objective-based
      industrial electrical code
    5 Top management responsibility
    6 Resource management
    7 Electrical installation realization
    8 Monitoring and measurement, control, analysis, and
      improvement
    Annexes
    A (normative) - Electrical equipment selection criteria

    Abstract - (Show below) - (Hide below)

    Contains: C22.4 No. 1-09 - Objective-based industrial electrical code; and C22.4 No. 2-09 - Objective-based industrial electrical code - Safety management system requirements.

    General Product Information - (Show below) - (Hide below)

    Development Note Includes CSA C22.4.1 & CSA C22.4.2. (01/2009)
    Document Type Standard
    Publisher Canadian Standards Association
    Status Superseded

    Standards Referencing This Book - (Show below) - (Hide below)

    ISA 61241-10 : 2004 ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - CLASSIFICATION OF ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS
    ISA 60079-7 : 2008 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E"
    IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
    IEC 60038:2009 IEC standard voltages
    CSA C22.4 No. 2 : 2009 OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE - SAFETY MANAGEMENT SYSTEM REQUIREMENTS
    ISA 60079-5 : 1998 EXPLOSIVE ATMOSPHERES - PART 5: EQUIPMENT PROTECTION BY POWDER FILLING 'Q'
    ISA RP2.1 : 1978 MANOMETER TABLES
    ISA 5.4 : 1991 INSTRUMENT LOOP DIAGRAMS
    ISA 12.10 : 1988 AREA CLASSIFICATION IN HAZARDOUS (CLASSIFIED) DUST LOCATIONS
    ISA 60079-27 : 2006 FIELDBUS INTRINSICALLY SAFE CONCEPT (FISCO) AND FIELDBUS NON-INCENDIVE CONCEPT (FNICO)
    ISA 61241-18 : 2006 ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - PROTECTION BY ENCAPSULATION "MD"
    C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
    CSA ISO 14001 : 2016 ENVIRONMENTAL MANAGEMENT SYSTEMS - REQUIREMENTS WITH GUIDANCE FOR USE
    ISA 5.5 : 1985 GRAPHIC SYMBOLS FOR PROCESS DISPLAYS
    IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
    IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
    ISA 61241-1 : 2006 ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - PROTECTION BY ENCLOSURES "TD"
    IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
    NFPA 70B : 2016 RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE
    NETA ATS : 2017 ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
    NETA MTS : 2011 MAINTENANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
    IEC 61241-0:2004 Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
    ISA 60079-1 : 2005 EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D"
    ISA 61241-2 : 2006 ELECTRICAL APPARATUS FOR USE IN ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - PROTECTION BY PRESSURIZATION "PD"
    IEC 61241-11:2005 Electrical apparatus for use in the presence of combustible dust - Part 11: Protection by intrinsic safety 'iD'
    IEEE 493 : 2007 DESIGN OF RELIABLE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS
    ISA 5.2 : 1976 BINARY LOGIC DIAGRAMS FOR PROCESS OPERATIONS
    ISA TR12.2 : 1995 INTRINSICALLY SAFE SYSTEM ASSESSMENT USING THE ENTITY CONCEPT
    IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
    IEC 60364-1:2005 Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions
    ISA RP12.4 : 1996 PRESSURIZED ENCLOSURES
    ISA RP12.12.03 : 2002 PORTABLE ELECTRONIC PRODUCTS SUITABLE FOR USE IN CLASS 1 AND 2, DIVISION 2, CLASS 1 ZONE 2 AND CLASS 3, DIVISION 1 AND 2 HAZARDOUS (CLASSIFIED) LOCATIONS
    ISA 60079-18 : 2005 EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION "M"
    IEEE 902-1998 IEEE Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book)
    IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    IEEE 835-1994 IEEE Standard Power Cable Ampacity Tables
    IEC 60364-6:2016 Low voltage electrical installations - Part 6: Verification
    ISA RP12.2.02 : 1996 RECOMMENDATIONS FOR THE PREPARATION, CONTENT, AND ORGANIZATION OF INTRINSIC SAFETY CONTROL DRAWINGS
    ISA 5.3 : 1983 GRAPHIC SYMBOLS FOR DISTRIBUTED CONTROL/SHARED DISPLAY INSTRUMENTATION, LOGIC AND COMPUTER SYSTEMS
    IEC 60079-27:2008 Explosive atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO)
    IEEE 242-2001 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book)
    ISA 60079-6 : 1998 EXPLOSIVE ATMOSPHERES - PART 6: EQUIPMENT PROTECTION BY OIL-IMMERSION 'O'
    IEEE 551 : 2006 CALCULATING SHORT-CIRCUIT CURRENTS IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS
    IEC 61241-1:2004 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
    IEEE C2-2017 NATIONAL ELECTRICAL SAFETY CODE (NESC)(R)
    API 505 : 1997 RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS I, ZONE 0, ZONE 1, AND ZONE 2
    ISA 61010-1 : 2008 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
    IEEE 142 : 2007 GROUNDING OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS
    NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
    IEC 60079-25:2010 Explosive atmospheres - Part 25: Intrinsically safe electrical systems
    IEC 61241-18:2004 Electrical apparatus for use in the presence of combustible dust - Part 18: Protection by encapsulation 'mD'
    IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
    IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
    IEEE 1100 : 2005 POWERING AND GROUNDING ELECTRONIC EQUIPMENT
    NFPA 499 : 2017 CLASSIFICATION OF COMBUSTIBLE DUSTS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS
    CSA C22.4 No. 1 : 2009(R2018) OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE
    CSA ISO 9001 : 2016 QUALITY MANAGEMENT SYSTEMS - REQUIREMENTS
    IEC 61241-4:2001 Electrical apparatus for use in the presence of combustible dust - Part 4: Type of protection "pD"
    ISA 7.0.01 : 1996 QUALITY STANDARD FOR INSTRUMENT AIR
    ISO/IEC Guide 2:2004 Standardization and related activities General vocabulary
    ISA 20 : 1981 SPECIFICATION FORMS FOR PROCESS MEASUREMENT AND CONTROL INSTRUMENTS, PRIMARY ELEMENTS AND CONTROL VALVES
    ISA 60079-0 : 2005 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
    IEC 60445:2017 Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors
    ISA 5.1 : 1984 INSTRUMENTATION SYMBOLS AND IDENTIFICATION
    ISA TR20.00.01 : 2006 SPECIFICATION FORMS FOR PROCESS MEASUREMENT AND CONTROL INSTRUMENTS - PART 1: GENERAL CONSIDERATIONS
    ISA 61241-11 : 2006 ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - PROTECTION BY INTRINSIC SAFETY "ID"
    IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
    IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
    IEC 60079-26:2014 RLV Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
    ISA 60079-15 : 2003 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N"
    ISA 61241-0 : 2006 ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS
    NFPA 497 : 2017 CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS
    CSA ISO 9000 : 2016 QUALITY MANAGEMENT SYSTEMS - FUNDAMENTALS AND VOCABULARY
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective