    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
       3.1 Terms and definitions
       3.2 Abbreviations
    4 General requirements
       4.1 General
       4.2 Compliance
    5 Functional requirements
       5.1 Alarm transmission routing equipment
       5.2 Fault warning routing equipment
       5.3 Indication of signals
    6 Alarm transmission and fault warning systems requirements
    7 Design requirements
       7.1 General requirements and manufacturer's declarations
       7.2 Documentation
       7.3 Mechanical design requirements
       7.4 Electrical and other design requirements
       7.5 Integrity of transmission paths
       7.6 Accessibility of indications and controls
       7.7 Indications by means of light-emitting indicators
       7.8 Colours of indications
       7.9 Testing of indicators
       7.10 Additional design requirements for software-controlled
             routing equipment
             7.10.1 General requirements and manufacturer's
                     declarations
             7.10.2 Software documentation
             7.10.3 Software design
             7.10.4 Program monitoring
             7.10.5 The storage of programs and data
             7.10.6 The monitoring of memory contents
    8 Marking
    9 Power supply
    10 Tests
       10.1 General
             10.1.1 Standard atmospheric conditions for testing
             10.1.2 Specimen configuration
             10.1.3 Mounting and orientation
             10.1.4 Electrical connection
             10.1.5 Provisions for tests
       10.2 Functional test
             10.2.1 Object of the test
             10.2.2 Test schedule
       10.3 Environmental tests
             10.3.1 General
             10.3.2 Tests for one specimen
             10.3.3 Tests for more than one specimen
             10.3.4 Requirements
       10.4 Cold (operational)
             10.4.1 Object of the test
             10.4.2 Test procedure
       10.5 Damp heat, steady state (operational)
             10.5.1 Object of the test
             10.5.2 Test procedure
       10.6 Impact (operational)
             10.6.1 Object of the test
             10.6.2 Test procedure
       10.7 Vibration, sinusoidal (operational)
             10.7.1 Object of the test
             10.7.2 Test procedure
       10.8 Electromagnetic (EMC) immunity tests (operational)
       10.9 Supply voltage variation (operational)
             10.9.1 Object of the test
             10.9.2 Test procedure
       10.10 Damp heat, steady state (endurance)
             10.10.1 Object of the test
             10.10.2 Test procedure
       10.11 Vibration, sinusoidal (endurance)
             10.11.1 The object of the test
             10.11.2 Test procedure
    Annex A (normative) Performance requirements for alarm and
             fault warning transmission systems
    Annex B (normative) Verification of performance requirements
             for alarm and fault warning transmission systems
      B.1 General
      B.2 Transmission time
      B.3 Reporting time
      B.4 Availability
    Annex C (informative) Design requirements for software
             controlled routing equipments
    Annex ZA (informative) Clauses of this European Standard
             addressing the provisions of the EU Construction
             Products Directive (89/106/EEC)
      ZA.1 Scope and relevant clauses
      ZA.2 Procedures for the attestation of conformity of
           alarm transmission and fault warning routing equipment
           covered by this standard
           ZA.2.1 System of attestation of conformity
           ZA.2.2 Evaluation of conformity
      ZA.3 CE marking and labelling and accompanying documentation
      ZA.4 EC certificate and declaration of conformity
    National Annex NA (informative) Bibliography

    Abstract - (Show below) - (Hide below)

    Describes requirements, test methods and performance criteria against which the effectiveness and reliability of routing equipment capable of transmitting fire alarm and/or fault warning signals for use with fire detection and fire alarm systems installed in buildings can be assessed.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    VDE 0833-2 :2017-10 ALARM SYSTEMS FOR FIRE, INTRUSION AND HOLD UP - PART 2: REQUIREMENTS FOR FIRE ALARM SYSTEMS
    EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    89/106/EEC : 1988 COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS
    EN 60068-1:2014 Environmental testing - Part 1: General and guidance
    EN 50136-1-1 : 98 AMD 2 2008 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 1-1: GENERAL REQUIREMENTS FOR ALARM TRANSMISSION SYSTEMS
    EN 54-2:1997/A1:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
    DIN VDE 0833-2:2017-10 ALARM SYSTEMS FOR FIRE, INTRUSION AND HOLD UP - PART 2: REQUIREMENTS FOR FIRE ALARM SYSTEMS
    IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
    EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    ISO 9001:2015 Quality management systems — Requirements
    EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
    IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
    EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
    IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    EN 54-4:1997/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT
    EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
    EN 50136-2-1 : 98 AMD 1 2001 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2-1: GENERAL REQUIREMENTS FOR ALARM TRANSMISSION EQUIPMENT
    EN 60068-2-47:2005 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests
    EN 60721-3-3 : 95 AMD 2 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective