    FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS

    Available format(s):  Hardcopy, PDF

    Language(s):  English, German

    Published date:  01-01-2015

    Publisher:  German Institute for Standardisation (Deutsches Institut für Normung)

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National foreword
    National Annex NA (informative) - Bibliography
    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
    4 Requirements
    5 Test and evaluation methods
    6 Assessment and verification of constancy of
      performance (AVCP)
    7 Classification
    8 Marking, labelling and packaging
    Annex A (normative) - Gas test chamber for CO
            response value and cross-sensitivity to
            chemical agents
    Annex A (normative) - Gas test chamber for CO
            response value and cross-sensitivity to
            chemical agents
    Annex C (normative) - Measuring instruments
            for smoke and CO
    Annex D (informative) - Establishing exposure
            levels of chemical agents
    Annex E (normative) - Heat tunnel for heat response
            value
    Annex F (normative) - Smouldering (pyrolysis)
            wood fire (TF2)
    Annex G (normative) - Glowing smouldering
            cotton fire (TF3)
    Annex H (normative) - Open plastics (polyurethane)
            fire (TF4)
    Annex I (normative) - Liquid (heptane) fire (TF5)
    Annex J (informative) - Information concerning
            the construction of the gas test chamber
    Annex K (informative) - Construction of the
            heat tunnel
    Annex L (informative) - Apparatus for impact test
    Annex ZA (informative) - Clauses of this European
             Standard addressing the provisions of the EU
             Construction Products Regulation
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in and around buildings (see EN 54-1:2011), incorporating in one mechanical enclosure at least one carbon monoxide sensor and at least one heat sensor and where the overall fire detection performance is determined utilizing the combination of the detected phenomena.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 209:2007 Aluminium and aluminium alloys — Chemical composition
    EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    VDE 0833-2 :2017-10 ALARM SYSTEMS FOR FIRE, INTRUSION AND HOLD UP - PART 2: REQUIREMENTS FOR FIRE ALARM SYSTEMS
    IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    EN 54-5:2017 Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
    EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    305/2011 : 2011 AMD 2 2014 REGULATION (EU) NO 305/2011 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 2011 LAYING DOWN HARMONISED CONDITIONS FOR THE MARKETING OF CONSTRUCTION PRODUCTS AND REPEALING COUNCIL DIRECTIVE 89/106/EEC (TEXT WITH EEA RELEVANCE)
    EN 60068-1:2014 Environmental testing - Part 1: General and guidance
    EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    DIN VDE 0833-2:2017-10 ALARM SYSTEMS FOR FIRE, INTRUSION AND HOLD UP - PART 2: REQUIREMENTS FOR FIRE ALARM SYSTEMS
    EN 54-26:2015 Fire detection and fire alarm systems - Part 26: Carbon monoxide detectors - Point detectors
    EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
    IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    ISO 9001:2015 Quality management systems — Requirements
    IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
    EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
    IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
    EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
    IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective