• EN 61000-2-2:2002/A1:2017

    Current The latest, up-to-date edition.

    ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017)

    Available format(s): 

    Language(s): 

    Published date:  27-10-2017

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope and object
    2 Normative references
    3 Definitions
    4 Compatibility levels
    Annex A (informative) - The function of compatibility
    Annex B (informative) - Discussion of some disturbance
            phenomena
    Annex C (informative) - Rationale for the compatibility
            levels for voltage distortion in differential mode
            above the 40th harmonic up to 30 kHz
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Provides compatibility levels for public low voltage a.c. distribution systems having a nominal voltage up to 420 V, single-phase, or 690 V, three-phase, and a nominal frequency of 50 Hz or 60 Hz.

    General Product Information - (Show below) - (Hide below)

    Committee TC 210
    Development Note Supersedes ENV 61000-2-2. (03/2005)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 60669-2-5:2016 Switches for household and similar fixed electrical installations Particular requirements. Switches and related accessories for use in home and building electronic systems (HBES)
    CLC/TS 50217:2005 Guide for in situ measurements - In situ measurement of disturbance emission
    DD CLC/TS 50217:2005 Guide for in situ measurements. In situ measurement of disturbance emission
    09/30214359 DC : 0 BS EN 50533 - RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
    10/30219053 DC : 0 BS EN 50130-4 - ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD - IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER AND SOCIAL ALARM SYSTEMS
    BS EN 62040-5-3:2017 Uninterruptible power systems (UPS) DC output UPS. Performance and test requirements
    I.S. CLC TR 50422:2005 GUIDE FOR THE APPLICATION OF THE EUROPEAN STANDARD EN 50160
    BS EN 50533 : 2011 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
    PREN 50130-4 : DRAFT 2010 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD - IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER AND SOCIAL ALARM SYSTEMS
    CEI EN 60146-2 : 2001 SEMICONDUCTOR CONVERTERS - PART 2: SELF-COMMUTATED SEMICONDUCTOR CONVERTERS INCLUDING DIRECT D.C. CONVERTERS
    CEI EN 61000-3-12 : 2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE
    BS EN 62040-1 : 2008 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS
    I.S. EN 62040-1-1:2004
    S.R. CLC/TR 50669:2017 INVESTIGATION RESULTS ON ELECTROMAGNETIC INTERFERENCE IN THE FREQUENCY RANGE BELOW 150 KHZ
    S.R. CLC/TR 50627:2015 STUDY REPORT ON ELECTROMAGNETIC INTERFERENCE BETWEEN ELECTRICAL EQUIPMENT/SYSTEMS IN THE FREQUENCY RANGE BELOW 150 KHZ
    S.R. HD 60364-5-51:2009 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES
    BS EN 62040-3:2011 Uninterruptible power systems (UPS) Method of specifying the performance and test requirements
    ETR 238 : 20001
    EN 61000-2-4:2002/AC:2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
    EN 12405-2:2012 Gas meters - Conversion devices - Part 2: Energy conversion
    EN 61000-4-13:2002/A2:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015)
    EN 61000-3-12:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011)
    EN 60831-1:2014/AC:2014 SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
    EN 62040-5-3:2017 Uninterruptible power systems (UPS) - Part 5-3: DC output UPS - Performance and test requirements
    EN 60669-2-5:2016 Switches for household and similar fixed electrical installations - Part 2-5: Particular requirements - Switches and related accessories for use in home and building electronic systems (HBES)
    EN 62310-2:2007 Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements
    EN 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
    EN 62040-1-2:2003/corrigendum:2004
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    CEI EN 61000-2-4 : 2003 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
    CEI EN 61000-3-2 : 2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
    CLC/TR 50422:2013 GUIDE FOR THE APPLICATION OF THE EUROPEAN STANDARD EN 50160
    BS EN 61000-4-19:2014 Electromagnetic compatibility (EMC) Testing and measurement techniques. Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
    BS EN 62040-1-1:2003 Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas
    I.S. EN 61800-3:2005 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004 (EQV))
    BS EN 50130-4 : 2011 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    I.S. EN 60669-2-5:2016 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 2-5: PARTICULAR REQUIREMENTS - SWITCHES AND RELATED ACCESSORIES FOR USE IN HOME AND BUILDING ELECTRONIC SYSTEMS (HBES)
    S.R. CLC/TR 50422:2013 GUIDE FOR THE APPLICATION OF THE EUROPEAN STANDARD EN 50160
    I.S. EN 61000-4-13:2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS
    CEI EN 62040-2 : 2006 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS
    UNE-EN 61000-3-12:2012 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and
    I.S. EN 62040-5-3:2017 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: DC OUTPUT UPS - PERFORMANCE AND TEST REQUIREMENTS
    I.S. EN 60146-1-1:2010 SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS
    I.S. EN 62040-1-2:2004
    I.S. EN 62040-3:2011 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS
    I.S. EN 62040-1:2008 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008 (EQV))
    I.S. EN 809:1998 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS
    VDI 3551:2011-01 Electromagnetic compatibility (EMC) in building services
    CEI EN 62040-3 : 2015 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS
    BS EN 62110:2009 Electric and magnetic field levels generated by AC power systems. Measurement procedures with regard to public exposure
    BS EN 61000-2-4:2002 Electromagnetic compatibility (EMC). Environment Compatibility levels in industrial plants for low-frequency conducted disturbances
    UNI EN 12405-2 : 2012 GAS METERS - CONVERSION DEVICES - PART 2: ENERGY CONVERSION
    BS EN 61000-4-7 : 2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO
    PD CLC/TR 50538:2010 Guide to EMC Directive conformity of equipment designed for military purposes
    EN 62040-3:2011 Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
    I.S. EN 50533:2011 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
    BS EN 61800-3 : 2004 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS
    CLC/TS 50509:2007 Use of LED signal heads in road traffic signal systems
    PD CLC/TR 50422:2013 Guide for the application of the European Standard EN 50160
    I.S. CLC/TS 50217:2005 GUIDE FOR IN SITU MEASUREMENTS - IN SITU MEASUREMENT OF DISTURBANCE EMISSION
    S.R. CLC/TS 50549-1:2015 REQUIREMENTS FOR GENERATING PLANTS TO BE CONNECTED IN PARALLEL WITH DISTRIBUTION NETWORKS - PART 1: CONNECTION TO A LV DISTRIBUTION NETWORK ABOVE 16 A
    CEI EN 61000-2-12 : 2004 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-12: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS
    UNE-EN 60669-2-5:2017 Switches for household and similar fixed electrical installations - Part 2-5: Particular requirements - Switches and related accessories for use in home and building electronic systems (HBES)
    S.R. CLC/TS 50509:2007 USE OF LED SIGNAL HEADS IN ROAD TRAFFIC SIGNAL SYSTEMS
    CLC/TR 50627:2015 Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz
    I.S. EN 60831-1:2014 SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
    BS EN 809 : 1998 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS
    UNE-EN 50160:2011 Voltage characteristics of electricity supplied by public electricity networks
    EN 809 : 1998 COR 2010 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS
    EN 809:1998+A1:2009 Pumps and pump units for liquids - Common safety requirements
    UNI EN 809 : 2009 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS
    UNE-EN 61000-4-7:2004 Electromagnetic compatibility (EMC) -- Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
    CEI CLC/TR 50422 : 2015 GUIDE FOR THE APPLICATION OF THE EUROPEAN STANDARD EN 50160
    I.S. EN 61000-2-12:2003 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS
    PD CLC/TR 50669:2017 Investigation Results on Electromagnetic Interference in the Frequency Range below 150 kHz
    BS EN 62310-3:2008 Static transfer systems (STS) Method for specifying performance and test requirements
    08/30180966 DC : DRAFT APR 2008 BS EN 50160 - VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC DISTRIBUTION NETWORKS
    DIN V ENV 50091-3 : 2000 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: PERFORMANCE REQUIREMENTS
    BS EN 61000-2-12:2003 Electromagnetic compatibility (EMC). Environment Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
    PD CLC/TR 50627:2015 Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz
    BS EN 62310-2:2007 Static transfer systems (STS) Electromagnetic compatibility (EMC) requirements
    BS EN 12405-2:2012 Gas meters. Conversion devices Energy conversion
    DD CLC/TS 50509:2007 Use of LED signal heads in road traffic signal systems
    UNE-EN 50130-4:2011 Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
    I.S. EN 50160:2010 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
    I.S. EN 12405-2:2012 GAS METERS - CONVERSION DEVICES - PART 2: ENERGY CONVERSION
    I.S. EN 62310-3:2008 STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD FOR SPECIFYING PERFORMANCE AND TEST REQUIREMENTS
    BS EN 61000-3-2:2014 Electromagnetic compatibility (EMC) Limits. Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
    I.S. EN 50130-4:2011 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    I.S. EN 60669-2-1:2004 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 2-1: PARTICULAR REQUIREMENTS - ELECTRONIC SWITCHES
    CEI EN 60146-1-1 : 2013 SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS
    CEI EN 62310-2 : 2007 STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS
    CEI EN 50533 : 2012 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
    DIN EN 809:2012-10 Pumps and pump units for liquids - Common safety requirements
    BS EN 60669-2-1 : 2004 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 2-1: PARTICULAR REQUIREMENTS - ELECTRONIC SWITCHES
    PREN 50539-11 : DRAFT 2010 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 11: REQUIREMENTS AND TESTS FOR SPDS IN PHOTOVOLTAIC APPLICATIONS
    UNE-EN 50533:2012 Railway applications - Three-phase train line voltage characteristics.
    BS EN 60831-1:2014 Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V General. Performance, testing and rating. Safety requirements. Guide for installation and operation
    PREN 50533 : DRAFT 2009 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
    DIN EN 12405-2:2012-10 GAS METERS - CONVERSION DEVICES - PART 2: ENERGY CONVERSION
    10/30218152 DC : 0 BS EN 50539-11 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 11: REQUIREMENTS AND TESTS FOR SPDS IN PHOTOVOLTAIC APPLICATIONS
    BS EN 61000-3-12:2011 Electromagnetic compatibility (EMC) Limits. Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and ≤ 75 A per phase
    CEI CLC/TS 50509 : 2008 USE OF LED SIGNAL HEADS IN ROAD TRAFFIC SIGNAL SYSTEMS
    I.S. EN 62310-2:2007 STATIC TRANSFER SYSTEMS (STS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS
    UNE-EN 12405-2:2013 Gas meters - Conversion devices - Part 2: Energy conversion
    BS EN 60146-1-1:2010 Semiconductor converters. General requirements and line commutated converters Specification of basic requirements
    CLC/TS 50549-1:2015 Requirements for generating plants to be connected in parallel with distribution networks - Part 1: Connection to a LV distribution network above 16 A
    BS EN 62040-2:2006 Uninterruptible power systems (UPS) Electromagnetic compatibility (EMC) requirements
    I.S. EN 61000-3-12:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011 (EQV))
    I.S. EN 61000-2-4:2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
    CEI EN 62310-3 : 2010 STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD FOR SPECIFYING PERFORMANCE AND TEST REQUIREMENTS
    I.S. EN 61000-3-2:2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
    I.S. EN 61000-4-7:2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO
    BS EN 61000-4-13 : 2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002)
    BS EN 50160 : 2010 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
    CLC/TR 50669:2017 Investigation Results on Electromagnetic Interference in the Frequency Range below 150 kHz
    EN 50160 : 2010 AMD 1 2015 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
    BS EN 809:1998+A1:2009 Pumps and pump units for liquids. Common safety requirements
    I.S. TR 50422:2004 GUIDE FOR THE APPLICATION OF THE EUROPEAN STANDARD EN 50160
    I.S. EN 62040-2:2006 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS
    EN 62040-1:2008/A1:2013 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008/A1:2013)
    EN 61800-3 : 2004 AMD 1 2012 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004/A1:2011)
    IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
    BS EN 62040-1-2:2003 Uninterruptible power systems (UPS) General and safety requirements for UPS used in restricted access locations
    EN 62110:2009/AC:2015 ELECTRIC AND MAGNETIC FIELD LEVELS GENERATED BY AC POWER SYSTEMS - MEASUREMENT PROCEDURES WITH REGARD TO PUBLIC EXPOSURE
    EN 60146-1-1:2010 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
    EN 61000-4-19:2014 Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
    EN 62040-1-1:2003/corrigendum:2004
    EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
    EN 62040-2:2006/corrigendum:2006
    EN 50533 : 2011 AMD 1 2016 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
    EN 61000-4-7:2002/A1:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO (IEC 61000-4-7:2002/A1:2008)
    EN 62310-3:2008 Static transfer systems (STS) - Part 3: Method for specifying performance and test requirements
    UNE-EN 809:1999 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-19:2014 Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
    IEC 60038:2009 IEC standard voltages
    IEC 61000-4-15 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-15: TESTING AND MEASUREMENT TECHNIQUES - FLICKERMETER - FUNCTIONAL AND DESIGN SPECIFICATIONS
    IEC 61000-2-4:2002 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
    IEC TR 61000-1-1:1992 Electromagnetic compatibility (EMC) - Part 1: General - Section 1: Application and interpretation of fundamental definitions and terms
    IEC TS 62578:2015 Power electronics systems and equipment - Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz
    IEC 61037:1990+AMD1:1996+AMD2:1998 CSV Electricity metering - Tariff and load control - Particular requirements for electronic ripple control receivers
    CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
    EN 61000-3-3:2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013)
    HD 625.1 : 200S1 INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PRINCIPLES, REQUIREMENTS AND TESTS
    CISPR 16-2-1:2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
    EN 61000-4-7:2002/A1:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO (IEC 61000-4-7:2002/A1:2008)
    IEC 60050-551:1998 International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics
    IEC 60050-101:1998 International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics
    IEC 61000-3-8:1997 Electromagnetic compatibility (EMC) - Part 3: Limits - Section 8: Signalling on low-voltage electrical installations - Emission levels, frequency bands and electromagnetic disturbance levels
    IEC 61000-4-15:2010 Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications
    IEC TR 61000-2-1:1990 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems
    IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
    IEC 61000-4-7:2002+AMD1:2008 CSV Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
    IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
    EN 50065-1:2011 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances
    CLC/TR 50627:2015 Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz
    IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    EN 61000-4-15:2011 Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications
    EN 55016-2-1:2014/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-1: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-2-1:2014/A1:2017)
    EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)
    IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective