• EN 61326-2-4:2013

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9

    Available format(s): 

    Superseded date:  06-07-2021

    Language(s): 

    Published date:  11-01-2013

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General
    5 EMC test plan
    6 Immunity requirements
    7 Emission requirements
    8 Test results and test report
    9 Instructions for use
    Annex A (normative) - Immunity test requirements for
            portable test and measurement equipment powered
            by battery or from the circuit being measured
    Bibliography
    Annex ZA (normative) - Normative references to international
             publications with their corresponding European
             publications
    Annex ZZ (informative) - Coverage of Essential Requirements
             of EU Directives

    Abstract - (Show below) - (Hide below)

    IEC 61236-2-4:2012 specifies detailed test configurations, operational conditions and performance criteria for equipment for insulation monitoring according to IEC 61557-8 and insulation fault location according to IEC 61557-9. This applies to insulation monitoring devices and insulation fault location systems permanently or semi-permanently connected to the distribution system. This second edition cancels and replaces the first edition published in 2006 and constitutes a technical revision. It includes the following significant technical change: update of the document with respect to IEC 61326-1:2012.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 65X
    Development Note Supersedes EN 61326. (12/2006) To be read in conjunction with EN 61326-1. (02/2007)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 61326-3-2:2008 ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - EMC REQUIREMENTS - PART 3-2: IMMUNITY REQUIREMENTS FOR SAFETY-RELATED SYSTEMS AND FOR EQUIPMENT INTENDED TO PERFORM SAFETY-RELATED FUNCTIONS (FUNCTIONAL SAFETY) - INDUSTRIAL APPLICATIONS WITH SPECIFIED ELECTROMAGNETIC ENVIRONMENT
    I.S. EN 61557-1:2007 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 1: GENERAL REQUIREMENTS
    CEI EN 61557-1 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 1: GENERAL REQUIREMENTS
    BS EN 61557-8:2015 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Insulation monitoring devices for IT systems
    EN 61326-3-2:2008 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment
    EN 61557-15:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems
    CEI EN 61326-3-2 : 2011 ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - EMC REQUIREMENTS - PART 3-2: IMMUNITY REQUIREMENTS FOR SAFETY-RELATED SYSTEMS AND FOR EQUIPMENT INTENDED TO PERFORM SAFETY-RELATED FUNCTIONS (FUNCTIONAL SAFETY) - INDUSTRIAL APPLICATIONS WITH SPECIFIED ELECTROMAGNETIC ENVIRONMENT
    EN 303 446-1 : 1.1.0 DRAFT ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 1: REQUIREMENTS FOR EQUIPMENT INTENDED TO BE USED IN RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRY LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU
    EN 61557-8:2015/AC:2016-06 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems
    EN 303 446-2 : 1.1.0 DRAFT ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 2: SPECIFIC CONDITIONS FOR EQUIPMENT INTENDED TO BE USED IN INDUSTRIAL LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU
    I.S. EN 61557-9:2015 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS
    UNE-EN 61557-8:2016 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems
    BS EN 61326-3-2:2008 Electrical equipment for measurement, control and laboratory use. EMC requirements Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety). Industrial applications with specified electromagnetic environment
    I.S. EN 61557-8:2015 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS
    CEI EN 61557-8 : 2016 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS
    BS EN 61557-1:2007 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures General requirements
    I.S. EN 61557-15:2014 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 15: FUNCTIONAL SAFETY REQUIREMENTS FOR INSULATION MONITORING DEVICES IN IT SYSTEMS AND EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS
    BS EN 61557-9:2015 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for insulation fault location in IT systems
    BS EN 61557-15:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems
    EN 61557-9:2015/AC:2017-02 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017)
    EN 61557-1:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements

    Standards Referencing This Book - (Show below) - (Hide below)

    2004/108/EC : 2004 DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC
    IEC 61557-1:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements
    EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
    IEC 61557-9:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems
    EN 61557-8:2015/AC:2016-06 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems
    IEC 61557-8:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems
    EN 61557-9:2015/AC:2017-02 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective