    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 General
      1.1 Scope
      1.2 Normative references
    2 General description
      2.1 Basic vocabulary
      2.2 Layers and protocols
      2.3 Specification language
      2.4 Communication services for local bus data
          exchange without DLMS
          2.4.1 Remote reading exchange
          2.4.2 Remote programming exchange
          2.4.3 Point to point remote transfer
                 exchange
          2.4.4 Broadcast remote transfer frame
          2.4.5 Bus initialization frame
          2.4.6 Forgotten station call exchange
          2.4.7 Frame fields
          2.4.8 Principle of the energy remote supply
          2.4.9 Non-energized station preselection
                 exchange
          2.4.10 Communication exchange after
                 preselection
          2.4.11 Alarm function
      2.5 Communication services for local bus data
          exchange with DLMS
      2.6 Systems management
    3 Local bus data exchange without DLMS
      3.1 Physical layer
          3.1.1 Physical-62056-31 protocol
          3.1.2 Physical parameters
          3.1.3 Timing diagrams
          3.1.4 Physical services and service
                 primitives
          3.1.5 State transitions
          3.1.6 List and processing of errors
      3.2 Data Link layer
          3.2.1 Link-62056-31 protocol
          3.2.2 Management of exchanges
          3.2.3 Data Link services and service
                 primitives
          3.2.4 Data Link parameters
          3.2.5 State transitions
          3.2.6 List and processing of errors
      3.3 Application layer
          3.3.1 Link-62056-31 protocol
          3.3.2 Application services and service
                 primitives
          3.3.3 Application parameters
          3.3.4 State transitions
          3.3.5 List and processing of errors
    4 Local bus data exchange with DLMS
      4.1 Physical layer
      4.2 Data Link layer
          4.2.1 Link-E/D protocol
          4.2.2 Management of exchanges
          4.2.3 Data Link services and service
                 primitives
          4.2.4 Data Link parameters
          4.2.5 State transitions
          4.2.6 List and processing of errors
      4.3 Application layer
          4.3.1 Transport sub-layer
          4.3.2 Application sub-layer
    5 Local bus data exchange - Hardware
      5.1 General
      5.2 General characteristics
          5.2.1 Signal transmission at 50 kHz
          5.2.2 Energy supply signal transmission
          5.2.3 Simple Secondary Station and multiple
                 Secondary Station
      5.3 Bus specification
          5.3.1 General characteristics
          5.3.2 Cable characteristics
          5.3.3 Wiring
      5.4 Magnetic plug
          5.4.1 Function
          5.4.2 Common mechanical characteristics
          5.4.3 Electrical Block diagram with simple
                 plug
          5.4.4 Electrical Block Diagram with energy
                 supply plug
      5.5 Functional specifications of Primary Station
          transmitter (for 50 kHz signal)
      5.6 Functional specifications of Primary Station
          receiver (for 50 kHz signal)
      5.7 Functional specification of Secondary Station
          transmitter (for 50 kHz signal)
      5.8 Functional specifications of Secondary Station
          receiver (for 50 kHz signal)
    Annex A (normative) Specification language
    Annex B (normative) Timing types and characteristics
    Annex C (normative) List of fatal errors
    Annex D (normative) Coding the command code field of frames
    Annex E (normative) Principle of the CRC
    Annex F (normative) Random integer generation for response
                           from forgotten stations
    Annex G (normative) Random number generation for
                           authentication (architecture without
                           DLMS)
    Annex H (normative) Systems management implementation
    Annex I (informative) Information about exchanges
    Annex ZA (normative) Normative references to international
                           publications with their corresponding
                           European publications

    Abstract - (Show below) - (Hide below)

    Describes two new architectures for local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. The first architecture completes the base protocol (EN 61142) with remote transfer services. The second architecture allows operation of DLMS services using the same physical medium and the same physical layer. This complete compatibility guarantees the possibility of using EN 61142 and IEC 62056-31 equipment on the same bus.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 13
    Development Note Supersedes EN 61142. (11/2000)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    EN 62056-62:2007 Electricity metering - Data exchange for meter reading, tariff and load control - Part 62: Interface classes
    12/30259441 DC : 0 BS EN 13757-1 - COMMUNICATION SYSTEM FOR AND REMOTE READING OF METERS - PART 1: DATA EXCHANGE
    PREN 13757-1 : DRAFT 2012 COMMUNICATION SYSTEM FOR AND REMOTE READING OF METERS - PART 1: DATA EXCHANGE
    I.S. EN 62056-62:2007 ELECTRICITY METERING - DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL - PART 62: INTERFACE CLASSES
    EN IEC 62056-6-2:2018 Electricity metering data exchange - The DLMS/COSEM suite - Part 6-2: COSEM interface classes
    CEI EN 62056-6-2 : 2014 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES
    BS EN 62056-6-2:2016 Electricity metering data exchange. The DLMS/COSEM suite COSEM interface classes
    BS EN 62056-62:2007 Electricity metering. Data exchange for meter reading, tariff and load control Interface classes
    I.S. EN 62056-6-2:2016 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES
    I.S. EN IEC 62056-6-2:2018 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 61334-4-41:1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 41: Application protocols - Distribution line message specification
    IEC TS 62056-51:1998 Electricity metering - Data exchange for meter reading, tariff and load control - Part 51: Application layer protocols
    IEC 61334-4-41:1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 41: Application protocol - Distribution line message specification
    TIA 485 : A1998(R2012) ELECTRICAL CHARACTERISTICS OF GENERATORS AND RECEIVERS FOR USE IN BALANCED DIGITAL MULTIPOINT SYSTEMS
    ISO/IEC 8482:1993 Information technology Telecommunications and information exchange between systems Twisted pair multipoint interconnections
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective