• EN 865 : 1997

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    PULSE OXIMETERS - PARTICULAR REQUIREMENTS

    Available format(s): 

    Superseded date:  01-03-2005

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    Section one. General
    1 Scope
    2 Normative references
    3 Terminology and definitions
    4 General requirements and general requirements for test
    5 Classification
    6 Identification marking and documents
    7 Power input
    Section two. Environmental conditions
    8 Basic safety categories
    9 Removable protective means
    10 Environmental conditions
    11 Not used
    12 Not used
    Section three. Protection against electric shock hazards
    13 General
    14 Requirements related to classification
    15 Limitation of voltage and/or energy
    16 Enclosures and protective covers
    17 Separation
    18 Protective earthing, functional earthing and potential
        equilization
    19 Continuous leakage currents and patient auxiliary
        currents
    20 Dielectric strength
    Section four. Protection against mechanical hazards
    21 Mechanical strength
    22 Moving parts
    23 Surfaces, corners and edges
    24 Stability in normal use
    25 Expelled parts
    26 Vibration
    27 Pneumatic and hydraulic power
    28 Suspended masses
    Section five. Protection against hazards from unwanted
    or excessive radiation
    29 X-radiation
    30 Alpha, beta, gamma, neutron radiation and other
        particle radiation
    31 Microwave radiation
    32 Light radiation (including lasers)
    33 Infra-red radiation
    34 Ultra-violet radiation
    35 Acoustical energy (including ultrasonic)
    36 Electromagnetic compatibility
    Section six. Protection against hazards of ignition of
    flammable anaesthetic mixtures
    37 Locations and basic requirements
    38 Marking, accompanying documents
    39 Common requirements for category AP and category APG
        equipment
    40 Requirements and tests for category AP equipment, parts
        and components thereof
    41 Requirements and tests for category APG equipment
        parts and components thereof
    Section seven. Protection against excessive temperatures
    and other safety hazards
    42 Excessive temperature
    43 Fire prevention
    44 Overflow, spillage, leakage, humidity, ingress of
        liquids, cleaning, sterilization, disinfection and
        compatibility
    45 Pressure vessels and parts subject to pressure
    46 Human error
    47 Electrostatic charges
    48 Biocompatibility
    49 Interruption of the power supply
    Section eight. Accuracy of operating data and protection
    against hazardous output
    50 Accuracy of operating data
    52 Protection against hazardous output
    Section nine. Abnormal operation and fault conditions;
    environmental tests
    52 Abnormal operation and fault conditions
    53 Environmental tests
    Section ten. Constructional requirements
    54 General
    55 Enclosures and covers
    56 Components and general assembly
    57 Mains parts, components and layout
    58 Protective earthing - terminals and connections
    59 Construction and layout
    Section eleven. Additional requirements specific to pulse
    oximeters
    101 Pulse amplitude
    Annex AA (informative) Rationale
    Annex BB (informative) Guidance on pulse signals
    Annex CC (informative) Bibliography
    Annex ZA (informative) Clauses of this European Standard
    addressing essential requirements or other provisions
    of EU Directives

    Abstract - (Show below) - (Hide below)

    ALSO NUMBERED AS BS 5724 SECTION 2.201 1997. Should be read in conjunction with EN 60601-1: 1990 Defines requirements for the safety of pulse oximeters as in 9.12 of this standard to be used in the approximate measurement of the saturation of human arterial haemoglobin, non-invasively.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/DTC 215
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 740:1999 ANAESTHETIC WORKSTATIONS AND THEIR MODULES - PARTICULAR REQUIREMENTS
    BS EN 13976-1:2011 Rescue systems. Transportation of incubators Interface conditions
    BS 5724-2.204(1999) : 1999 ANAESTHETIC WORKSTATIONS AND THEIR MODULES - PARTICULAR REQUIREMENTS
    EN 13976-1:2011 Rescue systems - Transportation of incubators - Part 1: Interface conditions
    I.S. EN 794-3:1998 LUNG VENTILATORS - PART 3: PARTICULAR REQUIREMENTS FOR EMERGENCY AND TRANSPORT VENTILATORS
    09/30205924 DC : 0 BS EN 13976-1 - RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    UNE-EN 13976-1:2011 Rescue systems - Transportation of incubators - Part 1: Interface conditions
    UNI EN 794-3 : 2009 LUNG VENTILATORS - PART 3: PARTICULAR REQUIREMENTS FOR EMERGENCY AND TRANSPORT VENTILATORS
    UNI EN 13976-1 : 2011 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    BS EN 794-3 : 1999 LUNG VENTILATORS - PART 3: PARTICULAR REQUIREMENTS FOR EMERGENCY AND TRANSPORT VENTILATORS
    DIN EN 13976-1 E : 2011 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    EN 740:1998/A1:2004 ANAESTHETIC WORKSTATIONS AND THEIR MODULES - PARTICULAR REQUIREMENTS
    EN 794-3:1998+A2:2009 Lung ventilators - Part 3: Particular requirements for emergency and transport ventilators
    DIN EN 13976-1:2016-03 (Draft) RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    I.S. EN 13976-1:2011 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    DIN EN 794-3:2009-12 Lung ventilators - Part 3: Particular requirements for emergency and transport ventilators; German version EN 794-3:1998+A2:2009
    DIN EN 13976-1:2011-08 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    UNE-EN 794-3:1999 LUNG VENTILATORS. PART 3: PARTICULAR REQUIREMENTS FOR EMERGENCY AND TRANSPORT VENTILATORS.

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 475 : 1995 MEDICAL DEVICES - ELECTRICALLY GENERATED ALARM SIGNALS
    EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    IEC 60801-2:1991 Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective