• I.S. EN 62199:2004

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    BUSHINGS FOR D.C. APPLICATION

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  20-02-2021

    Language(s):  English

    Published date:  01-01-2004

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Ratings
       4.1 Rated voltages
       4.2 Insulation levels
       4.3 Rated currents
       4.4 Minimum nominal creepage distance
    5 Operating conditions
       5.1 General
       5.2 Factors affecting the design, testing and application
    6 General requirements
       6.1 List of variables
       6.2 Nameplate markings
    7 Test requirements
       7.1 General requirements
       7.2 Test classification
    8 Type tests
       8.1 Dry power-frequency voltage withstand test with
            partial discharge measurement
       8.2 Dry lightning impulse voltage withstand test (BIL)
       8.3 Dry or wet switching impulse voltage withstand
       8.4 Temperature rise test
       8.5 Cantilever load withstand test
       8.6 Tightness test on liquid-filled, compound-filled
            and liquid-insulated bushings
       8.7 Internal pressure test on gas-filled, gas-insulated
            and gas-impregnated bushings
       8.8 Verification of dimensions
    9 Routine tests
       9.1 Measurement of dielectric dissipation factor
            (tan delta) and capacitances
       9.2 Dry lightning impulse voltage withstand test (BIL)
       9.3 Dry power-frequency voltage withstand test with
            partial discharge measurement
       9.4 DC applied voltage withstand test with partial
            discharge measurement
       9.5 Polarity reversal test with partial discharge
            measurement
       9.6 Test of tap insulation
       9.7 Internal pressure test on gas-filled, gas-insulated
            and gas-impregnated bushings
       9.8 Tightness test on liquid-filled, compound-filled
            and liquid-insulted bushings
       9.9 Tightness test on gas-filled, gas-insulated and
            gas-impregnated bushings
       9.10 Tightness test at the flange or other fixing device
       9.11 Visual inspection and dimensional check
    10 Special tests
       10.1 Artificial pollution test
       10.2 Even wetting d.c. voltage test
       10.3 Uneven wetting d.c. voltage test
    Annex ZA (normative) Normative references to international
                         publications with their corresponding
                         European publications
    Bibliography

    Abstract - (Show below) - (Hide below)

    Applicable to outdoor and indoor bushings of any voltage used on d.c. systems, of capacitance graded or gas insulated types for use as components of oil-filled converter transformers and smoothing reactors, as well as air-to-air d.c. bushings.

    General Product Information - (Show below) - (Hide below)

    Development Note For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Withdrawn
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
    IEC 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
    IEC TS 61462:1998 Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations
    IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
    EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
    HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
    EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
    IEC TS 61245:2015 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems
    EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    IEC TS 61463:2016 Bushings - Seismic qualification