• I.S. EN 62931:2017

    Current The latest, up-to-date edition.

    GX16T-5 CAPPED TUBULAR LED LAMP - SAFETY SPECIFICATIONS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2017

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National Foreword
    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General requirements and general test requirements
    5 Marking
    6 Interchangeability
    7 Protection against accidental contact with live parts
    8 Insulation resistance and electric strength after
       humidity treatment
    9 Mechanical requirements for caps
    10 Cap temperature rise
    11 Resistance to heat
    12 Resistance to flame and ignition
    13 Resistance to heat of insulating material of cap
    14 Fault conditions
    15 Creepage distances and clearances
    16 Ingress protection
    17 Photobiological safety
    18 Information for controlgear design
    19 Information for lampholder design
    20 Information for luminaire design
    Annex A (normative) - Test method for lamp cap
            temperature rise for GX16t-5 lamps
    Annex B (informative) - Information for controlgear
            design
    Annex C (informative) - Information for luminaire
            design
    Annex D (normative) - Dimensions and information
            to electrical characteristics
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Defines the safety and interchangeability requirements together with the test methods and conditions required to show compliance of non-integrated tubular LED lamps, intended for general lighting purposes, having: - a rated wattage up to 70 W, - a rated voltage up to 190 V ripple free DC, - GX16t-5 cap as listed in Table 1.

    General Product Information - (Show below) - (Hide below)

    Development Note For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2018)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60061-3:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
    EN 62031:2008/A2:2015 LED MODULES FOR GENERAL LIGHTING - SAFETY SPECIFICATIONS (IEC 62031:2008/A2:2014)
    IEC TR 62778:2014 Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires
    IEC 61347-2-13:2014+AMD1:2016 CSV Lamp controlgear - Part 2-13: Particular requirements for d.c. ora.c. supplied electronic controlgear for LED modules
    EN 60400:2017 Lampholders for tubular fluorescent lamps and starterholders
    IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
    IEC 60061-2:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 2: Lampholders
    IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
    IEC 60400:2017 Lampholders for tubular fluorescent lamps and starterholders
    IEC 60921:2004+AMD1:2006 CSV Ballasts for tubular fluorescent lamps - Performance requirements
    EN 60360:1998 Standard method of measurement of lamp cap temperature rise
    EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    EN 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
    IEC 62504:2014 General lighting - Light emitting diode (LED) products and related equipment - Terms and definitions
    IEC 60061-4:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 4: Guidelines and general information
    IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
    IEC 60061-1:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps
    IEC 62471:2006 Photobiological safety of lamps and lamp systems
    ISO 4046-4:2002 Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products
    IEC 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
    IEC 62031:2008+AMD1:2012+AMD2:2014 CSV LED MODULES FOR GENERAL LIGHTING - SAFETY SPECIFICATIONS
    IEC 60360:1998 Standard method of measurement of lamp cap temperature rise
    EN 60838-2-3:2017 Miscellaneous lampholders - Part 2-3: Particular requirements - Lampholders for double-capped linear LED lamps
    EN 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014)
    IEC 61195:1999+AMD1:2012+AMD2:2014 CSV Double-capped fluorescent lamps - Safety specifications
    IEC 60838-2-3:2016 Miscellaneous lampholders - Part 2-3: Particular requirements - Lampholders for double-capped linear LED lamps
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective