    Nuclear instrumentation - Amplifiers and preamplifiers used with detectors of ionizing radiation - Test procedures

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  31-12-2021

    Language(s):  English - French

    Published date:  15-09-1992

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    Clause
    1 General
       1.1 Scope and object
       1.2 Normative references
       1.3 Specialized definitions
       1.4 Symbols and abbreviations
       1.5 Constants and conversion factors
    2 Spectrometer
       2.1 Detectors
            2.1.1 Detector signal
            2.1.2 Rise time and fall time
       2.2 Preamplifier
       2.3 Main amplifier (shaping amplifier)
       2.4 Biased amplifier
       2.5 Multi channel analyzer
    3 Test instruments
       3.1 Test set-up
            3.1.1 Test instrument accuracy
            3.1.2 Measurement accuracy
       3.2 Pulse generators
            3.2.1 Pulse generator, preamplifier tests
            3.2.2 Pulse generator, main amplifier tests
       3.3 Step attenuator
            3.3.1 Attenuator termination
       3.4 Capacitor box
       3.5 Shaping amplifier
       3.6 A.C. voltmeter
       3.7 Oscilloscope
       3.8 Non-linearity bridge
       3.9 Oscilloscope/generator calibration
    4 Main amplifier measurements and specifications
       4.1 Pulse-shape parameters
            4.1.1 Front panel nomenclature, uni-polar
                   shaping
            4.1.2 Front panel nomenclature, bipolar shaping
       4.2 Pulse width
       4.3 Overload recovery
            4.3.1 Overload recovery time, uni-polar
            4.3.2 Overload recovery time, bipolar
            4.3.3 Blocking (paralysis)
            4.3.4 Baseline artifacts
       4.4 Gain control calibration and main amplifier gain
            measurement
            4.4.1 Coarse gain calibration
            4.4.2 Fine gain calibration
       4.5 Noise measurement
       4.6 Noise transition gain
       4.7 Pole/zero range
       4.8 Non-linearity
       4.9 Source resistance
       4.10 Temperature sensitivity
       4.11 Supply voltage sensitivity
       4.12 Crossover walk
    5 Preamplifier measurements
       5.1 Charge sensitivity
            5.1.1 Charge sensitivity versus capacitance
            5.1.2 Charge sensitivity versus capacitance,
                   MCA method
            5.1.3 Charge sensitivity versus capacitance,
                   bridge balance method
            5.1.4 Charge sensitivity versus capacitance
                   specifications
       5.2 Size of the internal test capacitor
       5.3 Rise time versus capacitance
       5.4 Noise, preamplifiers
            5.4.1 Noise, preamplifiers for germanium
                   detectors
            5.4.2 Noise, preamplifiers for silicon detectors
            5.4.3 Noise, units of equivalent r.m.s., charge
                   and equivalent r.m.s. ion pairs
            5.4.4 Correction for main amplifier noise
       5.5 Preamplifier non-linearity
       5.6 Energy x count-rate product (ECRP)
            5.6.1 Determination of Cf
            5.6.2 Determination of Rf Cf
            5.6.3 Count-rate limit, d.c.-coupled preamplifier
            5.6.4 Count-rate limit, a.c.-coupled preamplifier
    6 Biased amplifier measurements
       6.1 Non-linearity, biased amplifier
    ANNEXES
    A Spectrometer
    B Test instruments
    C Main amplifier measurements and specifications
    D Preamplifier noise measurements
    E Reference biased amplifier
    F Bibliography
    FIGURES

    Abstract - (Show below) - (Hide below)

    Covers test procedures for amplifier and preamplifier systems with linear pulse shaping networks for use with semiconductor, scintillation and proportional detectors in the spectrometry of ionizing radiation.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes IEC 340 (10/2001) Stability Date: 2013. (10/2012)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    DIN EN ISO 10703 E : 2015 WATER QUALITY - DETERMINATION OF THE ACTIVITY CONCENTRATION OF RADIONUCLIDES - METHOD BY HIGH RESOLUTION GAMMA-RAY SPECTROMETRY (ISO 10703:2007)
    BS EN ISO 10703:2015 Water quality. Determination of the activity concentration of radionuclides. Method by high resolution gamma-ray spectrometry
    06/30130038 DC : DRAFT MAY 2006 ISO 10703 - WATER QUALITY - DETERMINATION OF THE ACTIVITY CONCENTRATION OF RADIONUCLIDES - METHOD BY HIGH RESOLUTION GAMMA-RAY SPECTROMETRY
    NF ISO 10703 : 2008 WATER QUALITY - DETERMINATION OF THE ACTIVITY CONCENTRATION OF RADIONUCLIDES - METHOD BY HIGH RESOLUTION GAMMA-RAY SPECTROMETRY
    BS ISO 13164-2:2013 Water quality. Radon-222 Test method using gamma-ray spectrometry
    98/718930 DC : DRAFT JAN 1999 IEC 62089. ED. 1.0 - NUCLEAR INSTRUMENTATION - CALIBRATION AND USAGE OF ALPHA/BETA GAS PROPORTIONAL COUNTERS
    EN ISO 10703:2015 Water quality - Determination of the activity concentration of radionuclides - Method by high resolution gamma-ray spectrometry (ISO 10703:2007)
    I.S. EN ISO 10703:2015 WATER QUALITY - DETERMINATION OF THE ACTIVITY CONCENTRATION OF RADIONUCLIDES - METHOD BY HIGH RESOLUTION GAMMA-RAY SPECTROMETRY (ISO 10703:2007)
    UNE-EN ISO 10703:2016 Water quality - Determination of the activity concentration of radionuclides - Method by high resolution gamma-ray spectrometry (ISO 10703:2007)
    IEC 62088:2001 Nuclear instrumentation - Photodiodes for scintillation detectors - Test procedures
    API 551 : 2016 PROCESS MEASUREMENT
    98/718929 DC : DRAFT JAN 1999 IEC 62088. ED. 1.0 - NUCLEAR INSTRUMENTATION - PHOTODIODES FOR SCINTILLATION DETECTORS - TEST PROCEDURES
    ISO 13164-2:2013 Water quality — Radon-222 — Part 2: Test method using gamma-ray spectrometry
    IEC 61452:1995 Nuclear instrumentation - Measurement of gamma-ray emission rates of radionuclides - Calibration and use of germanium spectrometers
    DIN EN ISO 10703:2015-12 Water quality - Determination of the activity concentration of radionuclides - Method by high resolution gamma-ray spectrometry (ISO 10703:2007)
    12/30228762 DC : DRAFT JAN 2012 BS ISO 13164-2 - WATER QUALITY - MEASUREMENT OF THE ACTIVITY CONCENTRATION OF RADON-222 - PART 2: GAMMA SPECTROMETRY METHOD
    ISO 10703:2007 Water quality Determination of the activity concentration of radionuclides Method by high resolution gamma-ray spectrometry

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60973:1989 Test procedures for germanium gamma-ray detectors
    IEC 60313:2002 Coaxial connectors used in nuclear laboratory instrumentation
    IEC 60333:1993 Nuclear instrumentation - Semiconductor charged-particle detectors - Test procedures
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective