• IEC 61676:2002+AMD1:2008 CSV

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  21-03-2023

    Language(s):  English

    Published date:  26-01-2009

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope and object
    2 Normative references
    3 Terminology and definitions
    4 General performance requirements for measurement of
      PRACTICAL PEAK VOLTAGE measurements
      4.1 Quantity to be measured
      4.2 Limits of PERFORMANCE CHARACTERISTICS
      4.3 LIMITS OF VARIATION for effects of INFLUENCE
          QUANTITIES
      4.4 Performance test procedures
    5 Special instrumental requirements and marking
      5.1 Requirements for the complete instruments
      5.2 General
      5.3 Display
      5.4 Range of measurement
      5.5 Connectors and cables
    6 ACCOMPANYING DOCUMENTS
      6.1 General
      6.2 Information provided
      6.3 Instrument description
      6.4 Detector
      6.5 Delay time
      6.6 Measurement window
      6.7 Data outlet
      6.8 Transport and storage
    Annex A (informative) Recommended performance criteria
            for the invasive divider
    Annex B (informative) Additional information on PRACTICAL
            PEAK VOLTAGE
    Annex C (informative) Glossary of defined terms

    Abstract - (Show below) - (Hide below)

    Specifies the performance requirements of instruments as used in the non-invasive measurement of X-ray tube voltage up to 150 kV and the relevant compliance tests. Describes the method for calibration and gives guidance for estimating the uncertainty in measurements performed under conditions different from those during calibration. This standard is not concerned with the safety aspect of such instruments. The requirements for electrical safety applying to them are contained in IEC 61010-1. This consolidated version consists of the first edition (2002) and its amendment 1 (2008). Therefore, no need to order amendment in addition to this publication.

    General Product Information - (Show below) - (Hide below)

    Committee TC 62/SC 62C
    Development Note Stability Date: 2018. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 62467-1:2015 Medical electrical equipment. Dosimetric instruments as used in brachytherapy Instruments based on well-type ionization chambers
    17/30362279 DC : 0 BS EN 61223-3-6 - EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-6: ACCEPTANCE AND CONSTANCY TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC TOMOSYNTHESIS MODE OF OPERATION OF MAMMOGRAPHIC X-RAY EQUIPMENT
    BS EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments Acceptance tests. Imaging performance of mammographic X-ray equipment
    EN 62467-1:2015 Medical electrical equipment - Dosimetric instruments as used in brachytherapy - Part 1: Instruments based on well-type ionization chambers
    CEI EN 60731 : 2012 MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AS USED IN RADIOTHERAPY
    IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
    I.S. EN 61267:2006 MEDICAL DIAGNOSTIC X-RAY EQUIPMENT - RADIATION CONDITIONS FOR USE IN THE DETERMINATION OF CHARACTERISTICS
    BS ISO 16142-1:2016 Medical devices. Recognized essential principles of safety and performance of medical devices General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
    ISO 16142-1:2016 Medical devices — Recognized essential principles of safety and performance of medical devices — Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
    BS EN 60731:2012 Medical electrical equipment. Dosimeters with ionization chambers as used in radiotherapy
    I.S. EN 61223-3-2:2008 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-2: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT
    IEC 61223-3-2:2007 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment
    PD IEC TR 60788:2004 Medical electrical equipment. Glossary of defined terms
    09/30194820 DC : 0 BS EN 60731 - MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AS USED IN RADIOTHERAPY
    I.S. EN 60731:2012 MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AS USED IN RADIOTHERAPY (IEC 60731:2011 (EQV))
    BS EN 61267:2006 Medical diagnostic X-ray equipment. Radiation conditions for use in the determination of characteristics
    IEC 61267:2005 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
    CEI EN 61267 : 2006 MEDICAL DIAGNOSTIC X-RAY EQUIPMENT - RADIATION CONDITIONS FOR USE IN THE DETERMINATION OF CHARACTERISTICS
    I.S. EN 62467-1:2015 MEDICAL ELECTRICAL EQUIPMENT - DOSIMETRIC INSTRUMENTS AS USED IN BRACHYTHERAPY - PART 1: INSTRUMENTS BASED ON WELL-TYPE IONIZATION CHAMBERS
    IEC 62467-1:2009 Medical electrical equipment - Dosimetric instruments as used in brachytherapy - Part 1: Instruments based on well-type ionization chambers
    EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment
    EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
    EN 60731:2012 Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    IEC 61187:1993 Electrical and electronic measuring equipment - Documentation
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
    IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
    ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
    IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective