• IEC 62387-1:2007

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Radiation protection instrumentation - Passive integrating dosimetry systems for environmental and personal monitoring - Part 1: General characteristics and performance requirements

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  04-12-2012

    Language(s):  English - French

    Published date:  30-07-2007

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope and object
    2 Normative references
    3 Terms and definitions
    4 Units and symbols
    5 General test procedures
       5.1 Basic test procedures
       5.2 Test procedures to be considered for every test
    6 Performance requirements: summary
    7 Capability of a dosimetry system
       7.1 General
       7.2 Measuring range and type of radiation
       7.3 Rated ranges of the influence quantities
       7.4 Maximum rated measurement time t[max]
       7.5 Reusability
       7.6 Model function
       7.7 Example for the capabilities of a dosimetry system
    8 Requirements for the design of the dosimetry system
       8.1 General
       8.2 Indication of the dose value (dosimetry system)
       8.3 Assignment of the dose value to the dosemeter
             (dosimetry system)
       8.4 Information given on the devices (reader and
             dosemeter)
       8.5 Retention and removal of radioactive contamination
             (dosemeter)
       8.6 Algorithm to evaluate the indicated value (dosimetry
             system)
       8.7 Use of dosemeters in mixed radiation fields (dosimetry
             system)
    9 Instruction manual
       9.1 General
       9.2 Specification of the technical data
    10 Software, data and interfaces of the dosimetry system
       10.1 General
       10.2 Requirements
       10.3 Method of test
    11 Radiation performance requirements and tests (dosimetry
       system)
       11.1 General
       11.2 Coefficient of variation
       11.3 Non-linearity
       11.4 Overload characteristics, after-effects and reusability
       11.5 Radiation energy and angle of incidence for H[p](10)
             or H*(10) dosemeters
       11.6 Radiation energy and angle of incidence for H[p](0,07)
             dosemeters
       11.7 Radiation incidence from the side of an H[p](10) or
             H[p](0,07) dosemeter
    12 Additivity of the indicated value (dosimetry system)
       12.1 Requirements
       12.2 Method of test
       12.3 Interpretation of the results
    13 Environmental performance requirements and tests
       13.1 General
       13.2 Ambient temperature and relative humidity (dosemeter)
       13.3 Light exposure (dosemeter)
       13.4 Dose build-up, fading, self-irradiation and response
             to natural radiation (dosemeter)
       13.5 Sealing (dosemeter)
       13.6 Reader stability (reader)
       13.7 Ambient temperature (reader)
       13.8 Light exposure (reader)
       13.9 Primary power supply (reader)
       13.10 General interpretation of the results
    14 Electromagnetic performance requirements and tests
       (dosimetry system)
       14.1 General
       14.2 Requirement
       14.3 Method of test
       14.4 Interpretation of the results
    15 Mechanical performance requirements and tests
       15.1 General requirement
       15.2 Drop (dosemeter)
    16 Documentation
       16.1 Type test report
       16.2 Certificate issued by the laboratory performing
             the type test
    Annex A (normative) Confidence limits
    Annex B (informative) Causal connection between readout signals,
                          indicated value and measured value
    Annex C (informative) Overview of the necessary actions that
                          have to be performed for a type test
                          according to this standard
    Annex D (informative) Usage categories of passive dosemeters
    Bibliography

    Abstract - (Show below) - (Hide below)

    Applies to dosimetry systems that are capable of evaluating doses in the required quantity and unit (Sv) from readout signals in any quantity and unit. The only correction that may be applied to the evaluated dose (indicated value) is the one resulting from natural background radiation using extra dosemeters.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes IEC 61066. (02/2012) Stability Date: 2012. (10/2012)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    12/30250096 DC : 0 BS ISO 15690 - RADIOLOGICAL PROTECTION - RECOMMENDATIONS FOR DEALING WITH DISCREPANCIES BETWEEN PERSONAL DOSIMETER SYSTEMS USED IN PARALLEL

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC TR 62461:2015 Radiation protection instrumentation - Determination of uncertainty in measurement
    IEC 60050-394:2007 International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors
    ISO 4037-4:2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields
    ISO 6980-3:2006 Nuclear energy — Reference beta-particle radiation — Part 3: Calibration of area and personal dosemeters and the determination of their response as a function of beta radiation energy and angle of incidence
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    ISO 6980-2:2004 Nuclear energy — Reference beta-particle radiation — Part 2: Calibration fundamentals related to basic quantities characterizing the radiation field
    IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC 60904-3 : 3.0 PHOTOVOLTAIC DEVICES - PART 3: MEASUREMENT PRINCIPLES FOR TERRESTRIAL PHOTOVOLTAIC (PV) SOLAR DEVICES WITH REFERENCE SPECTRAL IRRADIANCE DATA
    ISO 12794:2000 Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyes
    IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
    ISO 8529-3:1998 Reference neutron radiations — Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence
    ISO 4037-2:1997 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
    ISO 8529-2:2000 Reference neutron radiations Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    IEC 60904-3:2016 Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data
    ISO 6980-1:2006 Nuclear energy — Reference beta-particle radiation — Part 1: Methods of production
    ISO 4037-1:1996 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods
    ISO 8529-1:2001 Reference neutron radiations Part 1: Characteristics and methods of production
    IEC 60359:2001 Electrical and electronic measurement equipment - Expression of performance
    IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
    ISO 4037-3:1999 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
    IEC 60050-300:2001 International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument
    IEC 60050-393:2003 International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective