• IEC 80601-2-49:2018

    Current The latest, up-to-date edition.

    Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitors

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French

    Published date:  08-03-2018

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    201.1 Scope, object and related standards
    201.2 Normative references
    201.3 Terms and definitions
    201.4 General requirements
    201.5 General requirements for testing ME
           EQUIPMENT
    201.6 Classification of ME EQUIPMENT and ME
           SYSTEMS
    201.7 ME EQUIPMENT identification, marking and
           documents
    201.8 Protection against electrical HAZARDS from
           ME EQUIPMENT
    201.9 Protection against MECHANICAL HAZARDS of
           ME EQUIPMENT and ME SYSTEMS
    201.10 Protection against unwanted and excessive
           radiation HAZARDS
    201.11 Protection against excessive temperatures
           and other HAZARDS
    201.12 Accuracy of controls and instruments and
           protection against hazardous outputs
    201.13 HAZARDOUS SITUATIONS and fault conditions
           for ME EQUIPMENT
    201.14 PROGRAMMABLE ELECTRICAL MEDICAL
           SYSTEMS (PEMS)
    201.15 Construction of ME EQUIPMENT
    201.16 ME SYSTEMS
    201.17 Electromagnetic compatibility of ME
           EQUIPMENT and ME SYSTEMS
    202 Electromagnetic disturbances - Requirements
           and tests
    206 USABILITY
    208 General requirements, tests and guidance for
           ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT
           and MEDICAL ELECTRICAL SYSTEMS
    Annexes
    Annex AA (informative) - Particular guidance and rationale
    Bibliography
    Index of defined terms used in this particular standard

    Abstract - (Show below) - (Hide below)

    IEC 80601-2-49:2018 applies to basic safety and essential performance requirements of multifunction patient monitors, hereafter referred to as ME equipment or medical electrical systems. This particular standard applies to multifunction patient monitors intended for use in professional healthcare facilities as well as in the emergency medical service environment or the home healthcare environment.
    The scope of this document is restricted to ME equipment or medical electrical systems intended for connection to a single patient that has two or more physiological monitoring units.
    For purposes of this document, a pregnant mother and her fetus(es) are considered a single patient.
    This document does not specify requirements for individual physiological monitoring units such as ECG, invasive pressure and pulse oximetry. The particular standards related to these physiological monitoring units specify requirements from the perspective of stand-alone ME equipment. This particular standard addresses the additional requirements related to multifunction patient monitors. Multifunction patient monitors can be integrated into other ME equipment or medical electrical systems. When this is the case, other relevant standards also apply.
    This document does not apply to implantable parts of multifunction patient monitors.
    This first edition cancels and replaces the second edition of IEC 60601-2-49, published in 2011. This edition constitutes a technical revision to align with the current edition and Amendment to IEC 60601-1, new versions of collateral standards and amendments thereto. Major changes are in Clause 208 because many of the former requirements are now addressed by IEC 60601-1-8.

    General Product Information - (Show below) - (Hide below)

    Committee TC 62/SC 62D
    Development Note Supersedes IEC 60601-2-49. Stability Date: 2022. (03/2018)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 80601-2-13:2011 Medical electrical equipment Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation
    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    ISO 80601-2-56:2017 Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
    IEC 60601-1-6:2010+AMD1:2013 CSV Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability
    IEC 60601-1-8:2006+AMD1:2012 CSV Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems
    IEC 60601-2-34:2011 Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment
    ISO 80601-2-12:2011 Medical electrical equipment Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators
    IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    IEC 60601-2-16 : 4.0 MEDICAL ELECTRICAL EQUIPMENT - PART 2-16: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HAEMODIALYSIS, HAEMODIAFILTRATION AND HAEMOFILTRATION EQUIPMENT
    IEC 60601-2-2:2017 Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
    ISO 80601-2-72:2015 Medical electrical equipment — Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60601-2-27:2011 Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective