• IEC PAS 62026-7:2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Low-voltage switchgear and controlgear - Controller-Device Interfaces (CDIs) - Part 7: CompoNet

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  09-12-2010

    Language(s):  English

    Published date:  31-08-2009

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms, definitions, symbols, abbreviated terms and
      conventions
      3.1 Terms and definitions
      3.2 Symbols and abbreviated terms
    4 Classification
      4.1 General
      4.2 Network specifications
      4.3 Components
      4.4 CompoNet communication model
      4.5 CompoNet and CIP
    5 Characteristics
      5.1 Communication cycle
          5.1.1 General
          5.1.2 Time domains
          5.1.3 A typical communication cycle
      5.2 Messaging protocol
          5.2.1 Message frame format
          5.2.2 Message frame types
          5.2.3 Explicit messaging
          5.2.4 Explicit messaging client/server timing requirement
      5.3 CompoNet communication object classes
          5.3.1 General
          5.3.2 Identity object class definition (class ID code:
                 01[Hex])
          5.3.3 Message router object class definition (class ID
                 code: 02[Hex])
          5.3.4 Connection object class definition (class ID code:
                 05[Hex])
          5.3.5 CompoNet Link object class definition (class ID code:
                 F7[Hex])
          5.3.6 CompoNet Repeater object (class ID code: F8[Hex])
      5.4 Network access state machine
          5.4.1 General
          5.4.2 Network access events
          5.4.3 State transition diagram
          5.4.4 Data rate auto-detection
          5.4.5 Duplicate MAC ID detection
          5.4.6 Repeater behaviour
      5.5 I/O connection
      5.6 TDMA
          5.6.1 General
          5.6.2 Data link timing features
          5.6.3 Calculation of Time Domain
      5.7 Physical layer
          5.7.1 General
          5.7.2 Physical signalling
          5.7.3 Master port requirements
          5.7.4 Slave port requirements
          5.7.5 Receiving signal requirements for master and
                 slave ports
          5.7.6 Requirements for digital processing
          5.7.7 Recommended circuits and component parameters
          5.7.8 Isolation
          5.7.9 Transmission medium
          5.7.10 Topology
          5.7.11 Link power
          5.7.12 Repeater implementation
    6 Product information
    7 Normal service, mounting and transport conditions
      7.1 Normal service conditions
          7.1.1 General
          7.1.2 Ambient air temperature
          7.1.3 Altitude
          7.1.4 Climatic conditions
      7.2 Conditions during transport and storage
      7.3 Mounting
    8 Constructional and performance requirements
      8.1 Indicators and configuration switches
          8.1.1 Status indicators
          8.1.2 Switches
          8.1.3 CompoNet marking
      8.2 CompoNet cable
          8.2.1 Overview
          8.2.2 Cable profile template
          8.2.3 Round cable I profile
          8.2.4 Round cable II profile
          8.2.5 Flat cable I profile
          8.2.6 Flat cable II profile
      8.3 Terminators
          8.3.1 General
          8.3.2 Terminating resistors
          8.3.3 Terminating capacitors
      8.4 Connectors
          8.4.1 General
          8.4.2 Template
          8.4.3 Engaging specification for connector profiles:
                 open, flat I, flat II
          8.4.4 Specifications of hooks for connector profiles:
                 open, flat I, flat II
          8.4.5 Open connector profile
          8.4.6 Profile of flat connector I
          8.4.7 Profile of flat connector II
          8.4.8 Profile of sealed M12 connector
      8.5 Node power supply implementation
          8.5.1 General
          8.5.2 Requirement for node power supply connection
          8.5.3 Requirements for nodes powered by network power
                 supplies
      8.6 Miswiring protection
    9 Tests
      9.1 General
      9.2 Electrical testing
          9.2.1 Slave port operation voltage test
          9.2.2 Reverse connected power supply line
          9.2.3 Momentary power interruption
          9.2.4 Isolation
          9.2.5 Input impedance
          9.2.6 Output waveform
          9.2.7 Minimum input waveform
          9.2.8 Electromagnetic compatibility testing
      9.3 Mechanical test
      9.4 Logical test
          9.4.1 General
          9.4.2 Term definitions
          9.4.3 Test of slaves and repeaters
          9.4.4 Test of master
    Annex A (normative) CompoNet common services
    Annex B (normative) CompoNet error codes
    Annex C (normative) Connection path attribute definition
    Annex D (normative) Data type specification and encoding
    Annex E (normative) Communication objects library
    Annex F (normative) Value ranges
    Annex G (normative) CN default time domain
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC/PAS 62026-7:2009(E) specifies an interface system providing bit-level and word-level communication between a controller and control circuit devices such as sensors, actuators, and switching elements. The interface system uses cabling with round or flat profiles containing a two conductor signalling pair and optionally a two conductor power supply pair. This PAS establishes requirements for the interchangeability of components with such interfaces. It specifies the following particular requirements for CompoNetTM:
    - requirements for interfaces between a controller and control circuit devices;
    - normal service conditions for devices;
    - constructional and performance requirements;
    - tests to verify conformance to requirements. These particular requirements apply in addition to the general requirements of IEC 62026-1.

    General Product Information - (Show below) - (Hide below)

    Document Type Miscellaneous Product
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC 7498-1:1994 Information technology Open Systems Interconnection Basic Reference Model: The Basic Model
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    IEC 61158-6-2:2014 Industrial communication networks - Fieldbus specifications - Part 6-2: Application layer protocol specification - Type 2 elements
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
    IEC 62026-3:2014 Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 3: DeviceNet
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
    IEC 62026-1:2007 Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 1: General rules
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    IEC 61131-2:2017 Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests
    IEC 61158-5-2:2014 Industrial communication networks - Fieldbus specifications - Part 5-2: Application layer service definition - Type 2 elements
    CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
    IEC 61076-2-101:2012 Connectors for electronic equipment - Product requirements - Part 2-101: Circular connectors - Detail specification for M12 connectors with screw-locking
    IEC 60512-1:2001 Connectors for electronic equipment - Tests and measurements - Part 1: General
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective