• IEEE 1899-2017

    Current The latest, up-to-date edition.

    IEEE Guide for Establishing Basic Requirements for High-Voltage Direct-Current Transmission Protection and Control Equipment

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  28-06-2017

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. Scope
    2. Normative references
    3. Definitions, acronyms, and abbreviations
    4. Overall structure of HVDC control and
       protection system
    5. HVDC control system
    6. HVDC protection system
    7. Secondary equipment related to HVDC control
       and protection
    8. Test of HVDC control and protection system
       equipment
    Annex A (informative) - Configuration of the control
            and protection systems in different HVDC projects
    Annex B (informative) - Configuration of measuring
            points in a control and protection system
    Annex C (informative) - Bibliography

    Abstract - (Show below) - (Hide below)

    Defines the basic norms for protection and control equipment of high-voltage direct-current (HVDC) transmission systems that have the voltage range up to and including 800 kV.

    General Product Information - (Show below) - (Hide below)

    Committee Entity Collaborative Activities Governance Bo
    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    S.R. CLC/TS 50654-2:2018 HVDC GRID SYSTEMS AND CONNECTED CONVERTER STATIONS - GUIDELINE AND PARAMETER LISTS FOR FUNCTIONAL SPECIFICATIONS - PART 2: PARAMETER LISTS
    CLC/TS 50654-2:2018 HVDC Grid Systems and connected Converter Stations - Guideline and Parameter Lists for Functional Specifications - Part 2: Parameter Lists
    PD CLC/TS 50654-1:2018 HVDC Grid Systems and connected Converter Stations. Guideline and Parameter Lists for Functional Specifications Guidelines
    PD CLC/TS 50654-2:2018 HVDC Grid Systems and connected Converter Stations. Guideline and Parameter Lists for Functional Specifications Parameter Lists
    S.R. CLC/TS 50654-1:2018 HVDC GRID SYSTEMS AND CONNECTED CONVERTER STATIONS - GUIDELINE AND PARAMETER LISTS FOR FUNCTIONAL SPECIFICATIONS - PART 1: GUIDELINES
    CLC/TS 50654-1:2018 HVDC Grid Systems and connected Converter Stations - Guideline and Parameter Lists for Functional Specifications - Part 1: Guidelines
    IEEE 2832-2023 IEEE Guide for Control and Protection System Test of Hybrid Multi-terminal High Voltage Direct Current (HVDC) Systems
    IEEE 2837-2023 IEEE Guide for Technical Requirements for Hybrid High-Voltage Direct Current Transmission Protection and Control Equipment

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
    IEC 61000-4-10 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-10: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY MAGNETIC FIELD IMMUNITY TEST
    IEC 61975:2010+AMD1:2016 CSV High-voltage direct current (HVDC) installations - System tests
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
    IEC 61000-4-9 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-9: TESTING AND MEASUREMENT TECHNIQUES - IMPULSE MAGNETIC FIELD IMMUNITY TEST
    IEEE 1378-1997 IEEE Guide for Commissioning High-Voltage Direct-Current (HVDC) Converter Stations and Associated Transmission Systems
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    IEC TR 60919-3:2009 Performance of high-voltage direct current (HVDC) systems with line-commutated converters - Part 3: Dynamic conditions
    IEC 60633:1998+AMD1:2009+AMD2:2015 CSV Terminology for high-voltage direct current (HVDC) transmission
    IEC 61000-4-18:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective