• ISO 13791:2012

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling General criteria and validation procedures

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  20-09-2018

    Language(s):  English, French

    Published date:  15-03-2012

    Publisher:  International Organization for Standardization

    Add To Cart

    Abstract - (Show below) - (Hide below)

    ISO 13791:2011 specifies the assumptions, boundary conditions, equations and validation tests for a calculation procedure, under transient hourly conditions, of the internal temperatures (air and operative) during warm periods, of a single room without any cooling/heating equipment in operation.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes ISO/FDIS 13791. (03/2012)
    Document Type Standard
    Publisher International Organization for Standardization
    Status Withdrawn
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN ISO 13792:2012 THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - SIMPLIFIED METHODS (ISO 13792:2012)
    DIN EN 15251 E : 2012 INDOOR ENVIRONMENTAL INPUT PARAMETERS FOR DESIGN AND ASSESSMENT OF ENERGY PERFORMANCE OF BUILDINGS ADDRESSING INDOOR AIR QUALITY, THERMAL ENVIRONMENT, LIGHTING AND ACOUSTICS
    10/30202119 DC : 0 BS EN ISO 13792 - THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - SIMPLIFIED METHODS
    BS EN 15242:2007 Ventilation for buildings. Calculation methods for the determination of air flow rates in buildings including infiltration
    DIN EN 15243 E : 2007 VENTILATION FOR BUILDINGS - CALCULATION OF ROOM TEMPERATURES AND OF LOAD AND ENERGY FOR BUILDINGS WITH ROOM CONDITIONING SYSTEMS
    ISO 52017-1:2017 Energy performance of buildings — Sensible and latent heat loads and internal temperatures — Part 1: Generic calculation procedures
    I.S. EN ISO 52016-1:2017 ENERGY PERFORMANCE OF BUILDINGS - ENERGY NEEDS FOR HEATING AND COOLING, INTERNAL TEMPERATURES AND SENSIBLE AND LATENT HEAT LOADS - PART 1: CALCULATION PROCEDURES (ISO 52016-1:2017)
    ISO 23045:2008 Building environment design Guidelines to assess energy efficiency of new buildings
    EN ISO 52016-1:2017 Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 1: Calculation procedures (ISO 52016-1:2017)
    DIN EN ISO 13792:2012-08 THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - SIMPLIFIED METHODS (ISO 13792:2012)
    CEN ISO/TR 52016-2:2017 Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1 (ISO/TR 52016-2:2017)
    BS EN 15243:2007 Ventilation for buildings. Calculation of room temperatures and of load and energy for buildings with room conditioning systems
    BS EN ISO 52016-1:2017 Energy performance of buildings. Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Calculation procedures
    I.S. EN 15255:2007 ENERGY PERFORMANCE OF BUILDINGS - SENSIBLE ROOM COOLING LOAD CALCULATION - GENERAL CRITERIA AND VALIDATION PROCEDURES
    PD CEN/TR 16798-4:2017 Energy performance of buildings. Ventilation for buildings Interpretation of the requirements in EN 16798-3. For non-residential buildings. Performance requirements for ventilation and room-conditioning systems(Modules M5-1, M5-4)
    15/30263791 DC : 0 BS ISO 17772-1 - ENERGY PERFORMANCE OF BUILDINGS - INDOOR ENVIRONMENTAL QUALITY - PART 1: INDOOR ENVIRONMENTAL INPUT PARAMETERS FOR THE DESIGN AND ASSESSMENT OF ENERGY PERFORMANCE OF BUILDINGS
    I.S. EN 15243:2007 VENTILATION FOR BUILDINGS - CALCULATION OF ROOM TEMPERATURES AND OF LOAD AND ENERGY FOR BUILDINGS WITH ROOM CONDITIONING SYSTEMS
    PRCEN/TR 15615 : DRAFT 2014 ENERGY PERFORMANCE OF BUILDINGS - MODULE M1-X - ACCOMPANYING TECHNICAL REPORT ON DRAFT OVERARCHING STANDARD EPB (PREN 15603)
    I.S. EN 15251:2007 INDOOR ENVIRONMENTAL INPUT PARAMETERS FOR DESIGN AND ASSESSMENT OF ENERGY PERFORMANCE OF BUILDINGS ADDRESSING INDOOR AIR QUALITY, THERMAL ENVIRONMENT, LIGHTING AND ACOUSTICS
    DIN EN 15255:2007-11 ENERGY PERFORMANCE OF BUILDINGS - SENSIBLE ROOM COOLING LOAD CALCULATION - GENERAL CRITERIA AND VALIDATION PROCEDURES
    DIN EN 15255 E : 2007 ENERGY PERFORMANCE OF BUILDINGS - SENSIBLE ROOM COOLING LOAD CALCULATION - GENERAL CRITERIA AND VALIDATION PROCEDURES
    BS EN ISO 13792:2012 Thermal performance of buildings. Calculation of internal temperatures of a room in summer without mechanical cooling. Simplified methods
    EN 14501:2005 Blinds and shutters - Thermal and visual comfort - Performance characteristics and classification
    VDI 2078:2015-06 Calculation of thermal loads and room temperatures (design cooling load and annual simulation)
    I.S. EN ISO 52017-1:2017 ENERGY PERFORMANCE OF BUILDINGS - SENSIBLE AND LATENT HEAT LOADS AND INTERNAL TEMPERATURES - PART 1: GENERIC CALCULATION PROCEDURES (ISO 52017-1:2017)
    DIN EN 15251:2012-12 Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics
    S.R. CEN ISO/TR 52016-2:2017 ENERGY PERFORMANCE OF BUILDINGS - ENERGY NEEDS FOR HEATING AND COOLING, INTERNAL TEMPERATURES AND SENSIBLE AND LATENT HEAT LOADS - PART 2: EXPLANATION AND JUSTIFICATION OF ISO 52016-1 AND ISO 52017-1 (ISO/TR 52016-2:2017)
    05/30134647 DC : DRAFT JUN 2005 EN 15255 - THERMAL PERFORMANCE OF BUILDINGS - SENSIBLE ROOM COOLING LOAD CALCULATION - GENERAL CRITERIA AND VALIDATION PROCEDURES
    PD CEN ISO/TR 52016-2:2017 Energy performance of buildings. Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Explanation and justification of ISO 52016-1 and ISO 52017-1
    DIN EN 15243:2007-10 VENTILATION FOR BUILDINGS - CALCULATION OF ROOM TEMPERATURES AND OF LOAD AND ENERGY FOR BUILDINGS WITH ROOM CONDITIONING SYSTEMS
    BS ISO 17772-1:2017 Energy performance of buildings. Indoor environmental quality Indoor environmental input parameters for the design and assessment of energy performance of buildings
    ISO 52016-1:2017 Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 1: Calculation procedures
    PREN ISO 13792 : DRAFT 2010 THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - SIMPLIFIED METHODS
    DIN EN 14501 E : 2006 BLINDS AND SHUTTERS - THERMAL AND VISUAL COMFORT - PERFORMANCE CHARACTERISTICS AND CLASSIFICATION
    ISO/TR 52016-2:2017 Energy performance of buildings Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
    ONORM B 8110-3 : 2012 THERMAL PROTECTION IN BUILDING CONSTRUCTION - PART 3: PREVENTION OF SUMMERLY OVERHEATING
    EN 15242:2007 Ventilation for buildings - Calculation methods for the determination of air flow rates in buildings including infiltration
    UNI EN ISO 13792 : 2012 THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - SIMPLIFIED METHODS
    CEN/TR 16798-4:2017 Energy performance of buildings - Ventilation for buildings - Part 4: Interpretation of the requirements in EN 16798- 3 - For non-residential buildings - Performance requirements for ventilation and room-conditioning systems(Modules M5-1, M5-4)
    UNI EN 15242 : 2008 VENTILATION FOR BUILDINGS - CALCULATION METHODS FOR THE DETERMINATION OF AIR FLOW RATES IN BUILDINGS INCLUDING INFILTRATION
    BS EN 15251:2007 Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics
    DIN EN 15242:2007-09 VENTILATION FOR BUILDINGS - CALCULATION METHODS FOR THE DETERMINATION OF AIR FLOW RATES IN BUILDINGS INCLUDING INFILTRATION
    ISO 17772-1:2017 Energy performance of buildings — Indoor environmental quality — Part 1: Indoor environmental input parameters for the design and assessment of energy performance of buildings
    BS EN 14501:2005 Blinds and shutters. Thermal and visual comfort. Performance characteristics and classification
    BS EN 15255:2007 Energy performance of buildings. Sensible room cooling load calculation. General criteria and validation procedures
    EN 15243:2007 Ventilation for buildings - Calculation of room temperatures and of load and energy for buildings with room conditioning systems
    EN ISO 13792:2012 Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - Simplified methods (ISO 13792:2012)
    EN 15255:2007 Energy performance of buildings - Sensible room cooling load calculation - General criteria and validation procedures
    EN 15251:2007 Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics
    UNE-EN ISO 13792:2013 Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - Simplified methods (ISO 13792:2012)
    DIN EN 15242 E : 2007 VENTILATION FOR BUILDINGS - CALCULATION METHODS FOR THE DETERMINATION OF AIR FLOW RATES IN BUILDINGS INCLUDING INFILTRATION
    BS EN ISO 52017-1:2017 Energy performance of buildings. Sensible and latent heat loads and internal temperatures Generic calculation procedures
    14/30296981 DC : 0 PD CEN/TR 15615 - ENERGY PERFORMANCE OF BUILDINGS - MODULE M1-X - ACCOMPANYING TECHNICAL REPORT ON DRAFT OVERARCHING STANDARD EPB (PREN 15603)
    I.S. EN 15242:2007 VENTILATION FOR BUILDINGS - CALCULATION METHODS FOR THE DETERMINATION OF AIR FLOW RATES IN BUILDINGS INCLUDING INFILTRATION
    S.R. CEN/TR 16798-4:2017 ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 4: INTERPRETATION OF THE REQUIREMENTS IN EN 16798-3 - FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS (MODULES M5-1, M5-4)
    EN ISO 52017-1:2017 Energy performance of buildings - Sensible and latent heat loads and internal temperatures - Part 1: Generic calculation procedures (ISO 52017-1:2017)
    ISO 13792:2012 Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling Simplified methods
    I.S. EN 14501:2005 BLINDS AND SHUTTERS - THERMAL AND VISUAL COMFORT - PERFORMANCE CHARACTERISTICS AND CLASSIFICATION
    DIN EN 14501:2006-02 Blinds and shutters - Thermal and visual comfort - Performance characteristics and classification

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 673:2011 Glass in building - Determination of thermal transmittance (U value) - Calculation method
    ISO 9346:2007 Hygrothermal performance of buildings and building materials — Physical quantities for mass transfer — Vocabulary
    EN 410:2011 Glass in building - Determination of luminous and solar characteristics of glazing
    ISO 15099:2003 Thermal performance of windows, doors and shading devices — Detailed calculations
    ISO 10077-2:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames
    ISO 9288:1989 Thermal insulation — Heat transfer by radiation — Physical quantities and definitions
    ISO 9050:2003 Glass in building — Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors
    ISO 13370:2017 Thermal performance of buildings — Heat transfer via the ground — Calculation methods
    ISO 15927-2:2009 Hygrothermal performance of buildings Calculation and presentation of climatic data Part 2: Hourly data for design cooling load
    ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods
    ISO 10077-1:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General
    ISO 9251:1987 Thermal insulation Heat transfer conditions and properties of materials Vocabulary
    ISO 7345:1987 Thermal insulation Physical quantities and definitions
    ISO 10292:1994 Glass in building — Calculation of steady-state U values (thermal transmittance) of multiple glazing
    • Access your standards online with a subscription