• ISO 39511:2018

    Current The latest, up-to-date edition.

    Sequential sampling plans for inspection by variables for percent nonconforming (known standard deviation)

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  French, English

    Published date:  18-05-2018

    Publisher:  International Organization for Standardization

    Add To Cart

    Abstract - (Show below) - (Hide below)

    This International Standard specifies sequential sampling plans and procedures for inspection by variables of discrete items.

    The plans are indexed in terms of producer's risk point and the consumer's risk point. Therefore, they are suitable not only for the purposes of acceptance sampling, but for the more general purpose of the testing of simple statistical hypotheses for proportions.

    The purpose of this International Standard is to provide procedures for the sequential assessment of inspection results that may be used to induce the supplier to supply lots of a quality having a high probability of acceptance. At the same time, the consumer is protected by a prescribed upper limit to the probability of accepting a lot (or process) of poor quality.

    This International Standard is primarily designed for use under the following conditions:

    a) where the inspection procedure is to be applied to a continuing series of lots of discrete products all supplied by one producer using one production process. In such a case, sampling of particular lots is equivalent to the sampling of the process. If there are different producers or production processes, this International Standard shall be applied to each one separately;

    b) where only a single quality characteristic x of these products is taken into consideration, which must be measurable on a continuous scale;

    c) where the measurement error is negligible (i.e. with a standard deviation no more than 10 % of the process standard deviation);

    d) where production is stable (under statistical control) and the quality characteristic x has a known standard deviation, and is distributed according to a normal distribution or a close approximation to the normal distribution;

    CAUTION — The procedures in this International Standard are not suitable for application to lots that have been screened previously for nonconforming items.

    e) where a contract or standard defines an upper specification limit U, a lower specification limit L, or both; an item is qualified as conforming if and only if its measured quality characteristic, x, satisfies the appropriate one of the following inequalities:

    1. xU (i.e. the upper specification limit is not violated);
    2. xL (i.e. the lower specification limit is not violated);
    3. and (i.e. neither the upper nor the lower specification limit is violated.)

    Inequalities 1) and 2) are called cases with a "single specification limit", and 3) is the case with "double specification limits".

    In this International Standard, it is assumed that, where double specification limits apply, conformance to both specification limits is either equally important to the integrity of the product or is considered separately for both specification limits. In the first case, it is appropriate to control the combined percentage of product outside the two specification limits. This is referred to as combined control. In the second case, nonconformity beyond each of the limits is controlled separately, and this is referred to as separate control.

    General Product Information - (Show below) - (Hide below)

    Committee ISO/TC 69/SC 5
    Development Note Supersedes ISO/DIS 39511 and ISO 8423. (05/2018)
    Document Type Standard
    Publisher International Organization for Standardization
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 3951-1:2013 Sampling procedures for inspection by variables — Part 1: Specification for single sampling plans indexed by acceptance quality limit (AQL) for lot-by-lot inspection for a single quality characteristic and a single AQL
    ISO 2854:1976 Statistical interpretation of data — Techniques of estimation and tests relating to means and variances
    ISO 7870-1:2014 Control charts Part 1: General guidelines
    ISO 3534-2:2006 Statistics Vocabulary and symbols Part 2: Applied statistics
    ISO 5479:1997 Statistical interpretation of data — Tests for departure from the normal distribution
    ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
    ISO 3951-5:2006 Sampling procedures for inspection by variables Part 5: Sequential sampling plans indexed by acceptance quality limit (AQL) for inspection by variables (known standard deviation)
    ISO 3534-1:2006 Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective