• NFC 01 426 : 2008 AMD 1 2015

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    ELECTROTECHNICAL VOCABULARY - PART 426: EQUIPMENT FOR EXPLOSIVE ATMOSPHERES

    Available format(s): 

    Withdrawn date:  03-02-2018

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    AVANT-PROPOS
    INTRODUCTION - Principes d'établissement et règles
                   suivies
    1 Domaine d'application
    2 Références normatives
    3 Termes et définitions
    Section 426-01 - Termes généraux
    Section 426-02 - phénomènes physiques et chimiques
    Section 426-03 - Emplacements et zones
    Section 426-04 - Construction des matériels électriques
                     (généralités)
    Section 426-05 - Essais des matériels électriques
    Section 426-06 - Enveloppe antidéflagrante 'D'
    Section 426-07 - Remplissage pulvérulent 'q'
    Section 426-08 - Sécurité augmentée 'e'
    Section 426-09 - Surpression interne 'p'
    Section 426-10 - Immersion dans l'huile 'o'
    Section 426-11 - Matériel électrique de sécurité intrinsèque
                     et matériel électrique associé de sécurité
                     intrinsèque 'i'
    Section 426-12 - Encapsulage 'm'
    Section 426-13 - Mode de protection 'n'
    Section 426-14 - Inspection et maintenance
    Section 426-15 - Réparation et entretien
    Section 426-16 - Protection par enveloppe (poussière) 'tD'
    Section 426-17 - Protection par surpression interne
                     (poussière) 'pD'
    Section 426-18 - Protection par encapsulage (poussière) 'mD'
    Section 426-19 - Protection de sécurité intrinsèque
                     (poussière) 'iD'
    Section 426-20 - Traçage
    BIBLIOGRAPHIE

    Abstract - (Show below) - (Hide below)

    La présente partie de la CEI 60050 définit les termes relatifs spécifiquement aux matériel pour atmosphères explosives.

    General Product Information - (Show below) - (Hide below)

    Development Note Indice de classement: C01-426. PR NFC 01 426 March 2006. (03/2006)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    NF EN 60079-29-2 : 2008 EXPLOSIVE ATMOSPHERES - PART 29-2: GAS DETECTORS - SELECTION, INSTALLATION, USE AND MAINTENANCE OF DETECTORS FOR FLAMMABLE GASES AND OXYGEN
    NF EN 60079-10 : 2003 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS
    NF EN 62086-1 : 2006 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL RESISTANCE TRACE HEATING - PART 1: GENERAL AND TESTING REQUIREMENTS

    Standards Referencing This Book - (Show below) - (Hide below)

    NF EN 60296 : 2014 FLUIDS FOR ELECTROTECHNICAL APPLICATIONS - UNUSED MINERAL INSULATING OILS FOR TRANSFORMERS AND SWITCHGEAR
    NF EN 60079-17 : 2014 EXPLOSIVE ATMOSPHERES - PART 17: ELECTRICAL INSTALLATIONS INSPECTION AND MAINTENANCE
    IEC 62013-2:2005 Caplights for use in mines susceptible to firedamp - Part 2: Performance and other safety-related matters
    IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
    NF EN 60079-11 : 2012 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'
    IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
    NF EN 62013-2 : 2006 CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - PART 2: PERFORMANCE AND OTHER SAFETY-RELATED MATTERS
    NF EN 60529 : 92 AMD 2 2014 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE)
    IEC 60079-1-1:2002 Electrical apparatus for explosive gas atmospheres - Part 1-1: Flameproof enclosures "d" - Method of test for ascertainment of maximum experimental safe gap
    NF EN 60079-25 : 2011 EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS
    IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
    NF EN 60079-15 : 2010 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
    IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60079-25:2010 Explosive atmospheres - Part 25: Intrinsically safe electrical systems
    IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
    IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective