• NFC 32 902 : 1998

    Current The latest, up-to-date edition.

    INSULATED CABLES AND CORDS FOR INSTALLATIONS - POWER CABLE ACCESSORIES INTENDED FOR INDUSTRY, FOR RATED VOLTAGE 0,6/1(1,2) KV - TEST METHODS AND TEST REQUIREMENTS

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Domaine d'application
    2 Références normatives
      2.1 Normes établies par l'Union Technique de
           l'Électricité (UTE)
      2.2 Publications de la Commission Électrotechnique
           Internationale (CEI)
      2.3 Normes établies par le CENELEC
    3 Définitions
    4 Caractéristiques électriques
      4.1 Tension assignée
      4.2 Intensités admissibles
    5 Acceptation de type
      5.1 Généralités
      5.2 Jonctions, dérivations et bouts perdus
      5.3 Jonctions et dérivations de transition
    6 Essais de type
      6.1 Généralités
      6.2 Échantillons pour les essais
      6.3 Séquence d'essais
      6.4 Conditions d'essai
      6.5 Fréquence et forme d'onde des tensions d'essai à
           fréquence industrielle
      6.6 Spécifications d'essai
           6.6.4 Tenue sous tension alternative
           6.6.5 (disponible)
           6.6.6 Choc mécanique à la température ambiante
           6.6.7 Mesure de la résistance d'isolement
           6.6.8 Cycles thermiques
           6.6.9 et 6.6.10 (disponibles)
           6.6.11 Essai d'immersion
           6.6.12 (disponible)
    7 Marquage, étiquetage, conditionnement et informations à
      donner par le fabricant
    Annexe A1 (normative) Détermination de la température de
                          l'âme du câble
      A1.1 Objet
      A1.2 Calibrage de la température de l'âme du câble en essai
      A1.3 Chauffage pendant l'essai de l'accessoire
    Annexe A2 (normative) Marquage, étiquetage, conditionnement
                          et informations à donner par le fabricant
      A2.1 Emballage
      A2.2 Marquage et étiquetage
      A2.3 Hygiène et sécurité
    Annexe B1 (normative) Essais des raccordements des âmes en
                          cuivre
      B1.1 Généralités
      B1.2 Essai de traction
      B1.3 Montage d'essai
      B1.4 Mesure de la chute de tension
      B1.5 Vieillissement

    Abstract - (Show below) - (Hide below)

    Ce document définit les prescriptions d'essai applicables aux accessoires des câbles d'énergie destinés aux installations industrielles et tertiaires de tension assignée 0,6/1(1,2) kV.

    General Product Information - (Show below) - (Hide below)

    Development Note Indice de classement: C32-902 PR NFC 32 902 February 1998. (05/2005)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60287-1-2:1993 Electric cables - Calculation of the current rating - Part 1: Current rating equations (100 % load factor) and calculations of losses - Section 2: Sheath eddy current loss factors for two circuits in flat formation
    IEC 60287-2-1:2015 RLV Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance
    NFC 32 321 : 82 AMD 1 93 INSULATED CONDUCTORS AND CABLES FOR INSTALLATIONS - CROSS-LINKED POLYETHYLENE INSULATED RIGID CABLES WITH A PROTECTIVE SHEATH OF POLYVINYL CHLORIDE
    IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV(Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
    NFC 63 061 : 1973 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONNECTION JOINTS FOR CONDUCTORS ONE AT LEAST OF THEM BEING AN INSULATED ALUMINIUM OR ALUMINIUM ALLOY CONDUCTOR - ELECTRICAL TEST REQUIREMENTS
    NFC 32 322 : 82 AMD 2 93 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CROSS-LINKED POLYETHYLENE INSULATED CABLES COVERED WITH A POLYVINYL CHLORIDE SHEATH, WITH A METALLIC ARMOUR
    NFC 20 130 : 2004 CRIMP-TYPE COPPER OR COPPER ALLOY NON-INSULATED LUGS FOR COPPER CONDUCTORS - REQUIREMENTS
    IEC 60287-3-1:2017 Electric cables - Calculation of the current rating - Part 3-1: Operating conditions - Site reference conditions
    IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
    HD 623 : S1 AMD 11 2001 SPECIFICATION FOR JOINTS, STOP ENDS AND OUTDOOR TERMINATIONS FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 KV
    NFC 32 111 : 82 AMD 2 95 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CROSS-LINKED POLYETHYLENE INSULATED CABLES
    EN 61180-1:1994 High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements
    IEC 60287-1-1:2006+AMD1:2014 CSV Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General
    NFC 15 100 : 2002 AMD 5 2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS
    NFC 33 002 : 98 AMD 1 2003 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - ACCESSORIES OF DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 (1,2) KV - TEST METHODS AND REQUIREMENTS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective