• UNI EN 13501-1 : 2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 1: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS

    Available format(s): 

    Superseded date:  03-08-2022

    Language(s): 

    Published date:  31-12-2008

    Publisher:  Ente Nazionale Italiano di Unificazione (UNI)

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    PREMESSA
    INTRODUZIONE
    1 SCOPO E CAMPO DI APPLICAZIONE
    2 RIFERIMENTI NORMATIVI
    3 TERMINI, DEFINIZIONI E SIMBOLI
    4 CLASSI DI REAZIONE AL FUOCO
    5 METODI DI PROVA E REGOLE PER IL CAMPO DI
       APPLICAZIONE
    6 PRINCIPI PER L'ESECUZIONE DELLE PROVE, LA
       PREPARAZIONE DELLE PROVETTE E IL CAMPO DI
       APPLICAZIONE
    7 NUMERO DI PROVE PER LA CLASSIFICAZIONE
    8 PROVE PER I PRODOTTI DA COSTRUZIONE, AD
       ECCEZIONE DEI PAVIMENTI
    9 PROVE PER I PAVIMENTI
    10 PROVE PER PRODOTTI DI FORMA LINEARE DESTINATI
       ALL'ISOLAMENTO TERMICO DI CONDOTTE
    11 CRITERI DI CLASSIFICAZIONE PER I PRODOTTI DA
       COSTRUZIONE, AD ECCEZIONE DEI PAVIMENTI
    12 CRITERI DI CLASSIFICAZIONE PER I PAVIMENTI
    13 CRITERI DI CLASSIFICAZIONE PER PRODOTTI DI FORMA
       LINEARE DESTINATI ALL'ISOLAMENTO TERMICO
       DI CONDOTTE
    14 PRESENTAZIONE DELLA CLASSIFICAZIONE
    15 CAMPO DI APPLICAZIONE DELLA CLASSIFICAZIONE
    16 RAPPORTO DI CLASSIFICAZIONE
    APPENDICE A (informativa) - INFORMAZIONE SULL'APPLICAZIONE
                DELLA DECISIONE DELLA COMMISSIONE DELL' 8
                FEBBRAIO 2000 CHE ATTUA LA
                DIRETTIVA 89/106/CEE DEL CONSIGLIO
                PER QUANTO RIGUARDA LA CLASSIFICAZIONE
                DI REAZIONE AL FUOCO DEI PRODOTTI
                DA COSTRUZIONE
    APPENDICE B (normativa) - RAPPORTO DI CLASSIFICAZIONE
                DI REAZIONE AL FUOCO
    BIBLIOGRAFIA

    Abstract - (Show below) - (Hide below)

    Gives the reaction to fire classification procedure for all construction products, including products incorporated within building elements.

    General Product Information - (Show below) - (Hide below)

    Development Note Bilingual (Italian + English) version issued in JULY 2012. (11/2012)
    Document Type Standard
    Publisher Ente Nazionale Italiano di Unificazione (UNI)
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNI 10683 : 2012 HEATING APPLIANCES FIRED BY WOOD OR OTHER SOLID BIOFUELS - INSTALLATION REQUIREMENTS
    UNI/TS 11343 : 2009 GAS PLANTS FOR DOMESTIC USE - GAS PLANTS FOR DOMESTIC USES SUPPLIED BY DISTRIBUTION NETWORKS, BY LPG CYLINDERS AND LPG STORAGE TANKS, PERFORMED WITH MULTILAYER PIPES - DESIGN, INSTALLATION AND MAINTENANCE
    UNI 8772 : 2012 UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC- U) PROFILES FOR ROLLER BLINDS - TYPES, REQUIREMENTS AND TESTS METHODS
    UNI 11518 : 2013 ETHANOL FIRED APPLIANCES - REQUIREMENTS AND TEST METHODS
    UNI 11528 : 2014 GAS PLANTS OVER 35 KW - DESIGN, INSTALLATION AND COMMISSIONING
    UNI 10372 : 2013 DISCONTINUOUSLY LAID ROOF COVERINGS - CRITERIA FOR DESIGN, EXECUTION AND MAINTENANCE OF ROOFING MADE OF METAL SHEETS
    UNI 11521 : 2014 STONE WALL AND CEILING COVERINGS - INSTRUCTION FOR THE DESIGN, INSTALLATION AND MAINTENANCE
    UNI 9795 : 2013 AUTOMATIC FIRE DETECTION AND FIRE ALARM SYSTEMS - DESIGN, INSTALLATION AND OPERATION
    UNI 8457 : 2010 COMBUSTIBLE PRODUCTS WHICH CAN BE HIT BY FLAME ON ONE SURFACE - REACTION TO FIRE BY APPLYING A SMALL FLAME
    UNI 8456 : 2010 COMBUSTIBLE PRODUCTS WHICH CAN BE HIT BY FLAME ON BOTH SURFACES - REACTION TO FIRE BY APPLYING A SMALL FLAME
    UNI/TS 11344 : 2009 METALLO-PLASTIC MULTILAYER PIPING SYSTEMS AND FITTINGS FOR INDOOR INSTALLATION FOR THE CONVEYANCE OF GASEOUS FUELS
    UNI 9174 : 2010 REACTION TO FIRE OF PRODUCTS WHICH CAN BE HIT BY FLAME WITH RADIANT HEATING
    UNI 11515 : 2014 RESILIENT AND LAMINATE FLOOR COVERINGS - INSTRUCTIONS FOR THE DESIGN, INSTALLATION AND MAINTENANCE
    UNI 11304-1 : 2008 TREATMENT PLANTS FOR PARTICULATE MATTER, MISTS, AEROSOLS AND VOLATILE ORGANIC COMPOUNDS (VOC) - MINIMUM PERFORMANCE AND DESIGN REQUIREMENTS - PART 1: DRY MEDIA DUST COLLECTORS
    UNI 9177 : 2008 REACTION TO FIRE - COMBUSTIBLE PRODUCTS CLASSIFICATION
    UNI 11342 : 2009 COPPER AND COPPER ALLOYS - COMPOSITE, SEAMLESS COPPER-PE, TUBES FOR FLUID DISTRIBUTION

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 9705:1993 Fire tests Full-scale room test for surface products
    ISO 1716:2010 Reaction to fire tests for products Determination of the gross heat of combustion (calorific value)
    ISO 11925-2:2010 Reaction to fire tests Ignitability of products subjected to direct impingement of flame Part 2: Single-flame source test
    EN ISO 1182:2010 Reaction to fire tests for products - Non-combustibility test (ISO 1182:2010)
    ISO 13943:2017 Fire safety — Vocabulary
    EN 13238:2010 Reaction to fire tests for building products - Conditioning procedures and general rules for selection of substrates
    ISO 1182:2010 Reaction to fire tests for products Non-combustibility test
    EN 13823:2010+A1:2014 REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM
    EN ISO 9239-1:2010 Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source (ISO 9239-1:2010)
    EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
    CEN/TS 15117:2005 Guidance on direct and extended application
    CEN/TS 15447:2006 Mounting and fixing in reaction to fire tests under the Construction Products Directive
    ISO 9239-1:2010 Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source
    EN ISO 1716:2010 Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) (ISO 1716:2010)
    EN ISO 11925-2:2010/AC:2011 REACTION TO FIRE TESTS - IGNITABILITY OF PRODUCTS SUBJECTED TO DIRECT IMPINGEMENT OF FLAME - PART 2: SINGLE-FLAME SOURCE TEST
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective