Foreword
Introduction
1 Scope
2 Normative References
2.1 Qualification and availability of references
2.2 Approved references
3 Definitions, abbreviations, conventions and keywords
3.1 Definitions
3.2 Editorial Conventions
3.3 Keywords
3.4 Notation
4 Corrected Definition of Clock Synchronization Primitive
Signals
4.1 Overview
4.2 10GFC structure
5 Functional characteristics
5.1 General characteristics
5.2 10GFC physical variant nomenclature
6 Optical interface specification
6.1 850 nm Parallel (4 lane) PMD, type 1200-MX-SN4P-I
6.2 850 nm Serial PMD, type 1200-MX-SN-I
6.3 850 nm CWDM (four wavelength) PMD, type 1200-MX-SN4-I
6.4 1310 nm Serial PMD, type 1200-SM-LL-L
6.5 1310 nm CWDM (four wavelength) PMD, type 1200-X-LC4-L
7 Optical interface receptacle specification
7.1 Optical interface connector
7.2 Optical receptacle
7.3 Optical plug
8 Optical interface cable plant specifications
8.1 Overview
8.2 Fiber optic cable plant model
8.3 Characteristics of the fiber optic cabling
9 FC-1 and 10GFC Levels
9.1 Definitions and nomenclature
9.2 Overview
9.3 Byte lane ordering
9.4 XGMII control characters and ordered set translation
9.5 XAUI idle characters
9.6 Ordered set mapping from XGMII to XAUI interface
9.7 10GFC Level functions
9.8 FC-1 level rules, requirements and functions
10 10 gigabit media independent interface (XGMII)
10.1 Overview
10.2 XGMII data stream
10.3 XGMII fault Indications
11 XGMII extender sublayer (XGXS) and 10 gigabit attachment
unit interface (XAUI)
11.1 XGXS and XAUI rate of operation
12 8B/10B physical coding sublayer (PCS) and physical medium
attachment (PMA) sublayers
12.1 Overview
12.2 Rate of operation
12.3 Ordered set mapping between XGMII and 8B/10B PCS
12.4 8B/10B PCS to XGMII mapping
12.5 Transmit and Receive state diagrams
13 Physical coding sublayer (PCS) for 64B/66B
13.1 Single lane 64B/66B bit encoding
14 10 gigabit sixteen bit interface (XSBI)
15 Port management
Annex A: Cable plant employing cross-connects (Informative)
A.1 Characteristics of fiber optic cabling
Annex B: 10GFC to SONET mapping (Normative)
Annex C: FC-AL-2 to 10GFC mapping (Informative)
C.1 Overview
C.2 FC-AL-2 mapping
C.3 Concerns about FC-AL-2 operation
C.4 Forcing LPSM to Point-to-Point Mode
Annex D: 8B/10B PCS State Diagrams (Informative)
D.1 Overview
D.2 Transmit source state diagram
D.3 PCS receive state diagram
Annex E: XAUI and 8B/10B PCS test patterns (Normative)
E.1 High frequency test pattern
E.2 Low frequency test pattern
E.3 Mixed frequency test pattern
E.4 Continuous jitter test pattern (CJPAT)