• ASTM F 1441 : 2003 : R2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Standard Specification for Soft-Tissue Expander Devices

    Available format(s):  Hardcopy, PDF

    Superseded date:  11-11-2014

    Language(s):  English

    Published date:  01-04-2009

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 13.01, 2015 Describes the requirements for single use saline inflatable, smooth and textured tissue expansion devices to be used intraoperatively or implanted for typically less than 6 months and then removed.

    Scope - (Show below) - (Hide below)

    1.1 This specification covers the requirements for single use saline inflatable, smooth and textured tissue expansion devices to be used intraoperatively or implanted for typically less than 6 months and then removed.

    1.2 Limitations:

    1.2.1 This specification applies only to soft-tissue expander devices fabricated with elastomer shells. It does not necessarily cover any custom fabricated soft tissue expander device manufactured to any other specification.

    1.2.2 This specification applies, in part, to combination expander/mammary devices as classified in Section 4.

    1.3 The values stated in SI units are to be regarded as standard, values in parentheses are for information only.

    1.4 The following statement pertains only to the test methods and requirements portion, Section 9, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    General Product Information - (Show below) - (Hide below)

    Committee F 04
    Document Type Standard
    Product Note Reconfirmed 2009
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 11135:2014 Sterilization of health-care products Ethylene oxide Requirements for the development, validation and routine control of a sterilization process for medical devices
    CFR 21(PTS800-1299) : 0 FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 800-1299
    ASTM D 1349 : 2014 : REDLINE Standard Practice for Rubber—Standard Conditions for Testing
    ASTM F 748 : 2016 : REDLINE Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices
    ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
    ISO 11134:1994 Sterilization of health care products — Requirements for validation and routine control — Industrial moist heat sterilization
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective