    Standard Specification for Surgical Gowns Intended for Use in Healthcare Facilities

    Available format(s):  Hardcopy, PDF

    Superseded date:  11-11-2014

    Language(s):  English

    Published date:  01-05-2006

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 11.03, 2014 Defines requirements for the performance, documentation, and labeling of surgical gowns used in the healthcare facilities.

    Scope - (Show below) - (Hide below)

    1.1 This specification establishes requirements for the performance, documentation, and labeling of surgical gowns used in the healthcare facilities. Four levels of barrier properties for surgical gowns are specified in AAMI PB70:2003 and are included in this specification for reference purposes.

    Note 1

    Some properties require minimum performance and others are for documentation only.

    Note 2

    AAMI PB70:2003 evaluates the barrier properties of surgical gown fabrics using water only in Levels 1, 2, and 3. Since surgical gowns are exposed to blood and other fluids with different surface tensions, the performance of additional testing to identify the barrier levels to simulated biological fluids is required for a Level 4 gown.

    1.2 This specification does not cover all the requirements that a healthcare facility deems necessary to select a product, nor does it address criteria for evaluating experimental products.

    1.3 This specification is not intended to serve as a detailed manufacturing or purchase specification, but can be referenced in purchase specifications as the basis for selecting test requirements.

    1.4 The values stated in SI units or in other units shall be regarded separately as standard. The values stated in each system must be used independently of the other, without combining values in any way.

    This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    General Product Information - (Show below) - (Hide below)

    Committee F 23
    Document Type Standard
    Product Note Reconfirmed 2006
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    ASTM F 3352 : 2019 Standard Specification for Isolation Gowns Intended for Use in Healthcare Facilities
    ASTM F 1494 : 2014 Standard Terminology Relating to Protective Clothing

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM D 5733 : 1999 Standard Test Method for Tearing Strength of Nonwoven Fabrics by the Trapezoid Procedure (Withdrawn 2008)
    ASTM D 6701 : 2016 Standard Test Method for Determining Water Vapor Transmission Rates Through Nonwoven and Plastic Barriers
    ISO 11135:2014 Sterilization of health-care products Ethylene oxide Requirements for the development, validation and routine control of a sterilization process for medical devices
    ISO 3951:1989 Sampling procedures and charts for inspection by variables for percent nonconforming
    AAMI TIR 11 : 2005 SELECTION AND USE OF PROTECTIVE APPAREL AND SURGICAL DRAPES IN HEALTH CARE FACILITIES
    ASTM D 5587 : 2015 : REDLINE TEST METHOD FOR TEARING STRENGTH OF FABRICS BY TRAPEZOID PROCEDURE
    CFR 21(PTS800-1299) : 0 FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 800-1299
    CFR 16(PTS1000-END) : 0 COMMERCIAL PRACTICES - FEDERAL TRADE COMMISSION - CONSUMER PRODUCT SAFETY COMMISSION
    AAMI BE78 : 2002 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 10: TESTS FOR IRRITATION AND DELAYED TYPE HYPERSENSITIVITY
    AAMI ST65:2008(R2018) PROCESSING OF REUSABLE SURGICAL TEXTILES FOR USE IN HEALTH CARE FACILITIES
    ISO 10993-10:2010 Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization
    CFR 29(PT1910.1000 TO END) : 0 LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
    ISO 9073-10:2003 Textiles Test methods for nonwovens Part 10: Lint and other particles generation in the dry state
    ISO 11134:1994 Sterilization of health care products — Requirements for validation and routine control — Industrial moist heat sterilization
    ASTM F 1494 : 2014 : REDLINE Standard Terminology Relating to Protective Clothing
    ASTM F 1868 : 2017 : REDLINE Standard Test Method for Thermal and Evaporative Resistance of Clothing Materials Using a Sweating Hot Plate
    ISO 11137:1995 Sterilization of health care products Requirements for validation and routine control Radiation sterilization
    ANSI/AAMI PB70:2012 LIQUID BARRIER PERFORMANCE AND CLASSIFICATION OF PROTECTIVE APPAREL AND DRAPES INTENDED FOR USE IN HEALTH CARE FACILITIES
    ISO 13683:1997 Sterilization of health care products Requirements for validation and routine control of moist heat sterilization in health care facilities