• BS 5234-2:1992

    Current The latest, up-to-date edition.

    Partitions (including matching linings) Specification for performance requirements for strength and robustness including methods of test

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  15-12-1992

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    Specification
    Section 1. General
    1.1 Scope
    1.2 References
    1.3 Definitions
    1.4 Grades
    1.5 Performance requirements
    1.6 Criteria for acceptance
    Section 2. Testing
    2.1 General
    2.2 Partition specimen
    2.3 Test rig
    2.4 Conditioning
    2.5 Sequence of tests
    2.6 Test report
    Annexes
    A (normative) Determination of partition stiffness
    B (normative) Determination of surface damage by
         small hard body impact
    C (normative) Determination of resistance to damage
         by impact from a large soft body
    D (normative) Determination of resistance to
         perforation by small hard body impact
    E (normative) Determination of resistance to
         structural damage by multiple impacts from a large
         soft body
    F (normative) Determination of the effects of door
         slamming
    G (normative) Determination of resistance to crowd
         pressure
    H (normative) Lightweight anchorage pull-out test
    J (normative) Lightweight anchorage pull-down test
    K (normative) Heavyweight anchorage (wash basin)
         eccentric downward loading test
    L (normative) Heavyweight anchorage (high level wall
         cupboard) eccentric downward loading test
    M (normative) Summary of test reports
    Figures
    1 Partition specimen dimensions
    2 Partition specimen of panel components
    3 Partition junction
    B.1 Apparatus for small hard body impact test
    B.2 Impact at partition junction (small hard body)
    C.1 50 kg spheroconical bag
    C.2 Test apparatus for large soft body impact test
    C.3 Impact at partition junction (large soft body)
    F.1 Fixing positions for standard door frame
    F.2 Arrangement for door slamming test
    H.1 Shim plates
    H.2 Lightweight anchorage pull-out test
    J.1 Lightweight anchorage pull-down test
    K.1 Heavyweight anchorage (wash basin) test apparatus
    K.2 Location of wash basin brackets and measuring
         instruments
    K.3 Heavyweight anchorage (wash basin) loading sequence
    L.1 Heavyweight anchorage (wall cupboard) test
         apparatus
    L.2 Location of wall cupboard brackets and measuring
         instruments
    M.1 Example of a 'Summary of test reports'
    Tables
    1 Partition grades by categories of duty
    2 Summary of grade requirements and principal test
         performance levels
    3 Summary of tests for crowd pressure, lightweight
         anchorages and heavyweight anchorages
    4 Stiffness: applied loads and deflection limits
    5 Small hard body impact test (surface damage)
    6 Large soft body impact test (damage)
    7 Small hard body impact test (perforation)
    8 Large soft body impact test (structural damage)
    9 Door slam: door leaf weights and number of slams
    10 Heavyweight anchorage (wash basin): applied loads
         and deflection limits
    11 Heavyweight anchorage (high level wall cupboard):
         applied loads and deflection limits
    B.1 Angles of swing for small hard body impact test:
         surface damage
    D.1 Angles of swing for resistance to perforation test

    Abstract - (Show below) - (Hide below)

    For a sample partition with a door when tested by the methods given in the annexes. Grades derived when tested for stiffness, hard and soft body impacts and door slamming. Performance levels and test methods are also given for crowd pressure, lightweight and heavyweight anchorages.

    Scope - (Show below) - (Hide below)

    This Part of BS 5234 specifies the performance requirements for strength and robustness of a sample partition when tested by the methods given in the annexes.

    The partition specimen to be tested is defined and includes a doorset and the surface finish of the partition where this is supplied as part of the partition.

    Partition grade can be derived when all the relevant tests are applied to the test specimen and, where specified, to the specimen right-angle partition junction.

    Performance levels are given for each requirement tested based on the frequency and/or intensity of the loads on the partition.

    Methods of test are given for stiffness, hard and soft body impacts, door slamming, crowd pressure and for anchorages for lightweight fittings, wash basins and wall cupboards.

    NOTE 1 Tests may be used individually or in combination.

    A specimen right-angle junction is required to be tested for surface damage and perforation by a small hard body and for its resistance to damage by impact from a large soft body. Other junctions may be tested by the methods given in this standard but such tests are beyond its scope.

    Lightweight and heavyweight anchorage tests specify brackets that are to be used to evaluate the performance level of the partition. Proprietary brackets may not be substituted to demonstrate conformance to this standard. Alternative test brackets may be used but such tests are beyond the scope of this standard.

    The requirements tested may be applied to a partition regardless of the materials used in its construction. However, it would be unnecessary and/or inappropriate to apply some tests to some forms of construction; for example, heavyweight anchorage tests on movable partitions, screens or WC cubicles, hard body impact test on the glass of glazed partitions, etc. Masonry partitions should be designed for structural requirements in accordance with BS 5628-1:1978, BS 5628-2:1985 and BS 5628-3:1985. However, the design of some masonry partitions may need modification to achieve some of the performance criteria when tested by the methods given in this Part of BS 5234.

    This standard does not include requirements for wind loading.

    NOTE 2 If the partition specimen, when tested for crowd pressure as given in Annex G, meets the requirement of 0.75 kN/m this may be sufficient to satisfy the wind loading requirement. (See 8.4 of BS 5234-1:1992.)

    General Product Information - (Show below) - (Hide below)

    Committee B/544
    Development Note Supersedes 90/15332 DC. (07/2005) Reviewed and confirmed by BSI, November 2007. (10/2007)
    Document Type Standard
    Publisher British Standards Institution
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    12/30263295 DC : 0 BS 8524-1 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 1: SPECIFICATION
    BS 8524-1:2013 Active fire curtain barrier assemblies Specification
    BS 5588-10:1991 Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes
    BS 9999:2008 Code of practice for fire safety in the design, management and use of buildings
    BS 9991:2015 Fire safety in the design, management and use of residential buildings. Code of practice
    BS 5588-5:1991 Fire precautions in the design, construction and use of buildings Code of practice for firefighting stairs and lifts
    BS 9991:2011 Fire safety in the design, management and use of residential buildings. Code of practice
    15/30301829 DC : 0 BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE
    11/30203947 DC : 0 BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE
    16/30314117 DC : 0 BS 9999 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF BUILDINGS - CODE OF PRACTICE
    BS 5234-1:1992 Partitions (including matching linings) Code of practice for design and installation

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 5234-1:1992 Partitions (including matching linings) Code of practice for design and installation
    ISO 7894:1987 Partitions made of components Test for resistance to wind (static pressure and slamming doors)
    BS 5628-3:1985 Code of practice for use of masonry Materials and components, design and workmanship
    BS 4787-1:1980 Internal and external wood doorsets, door leaves and frames Specification for dimensional requirements
    BS 4978:1988 Specification for softwood grades for structural use
    ISO 7892:1988 Vertical building elements — Impact resistance tests — Impact bodies and general test procedures
    BS 5628-2:1985 Code of practice for use of masonry Structural use of reinforced and prestressed masonry
    BS 5628-1:1978 Code of practice for use of masonry Structural use of unreinforced masonry
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective