• BS EN 12015:2014

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electromagnetic compatibility. Product family standard for lifts, escalators and moving walks. Emission

    Available format(s):  Hardcopy, PDF

    Superseded date:  23-06-2020

    Language(s):  English

    Published date:  30-04-2014

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Test set-up procedure
    5 Applicability of tests
    6 Emission limits
    7 Documentation for the installer of the
      apparatus/assembly of apparatus
    Annex ZA (informative) - Relationship between
             this European Standard and the Essential
             Requirements of Directive 2004/108/EC
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes the emission limits in relation to electromagnetic disturbances and test conditions for lifts, escalators and moving walks, which are intended to be permanently installed in buildings.

    Scope - (Show below) - (Hide below)

    This European Standard specifies the emission limits in relation to electromagnetic disturbances and test conditions for lifts, escalators and moving walks, which are intended to be permanently installed in buildings. These limits however, may not provide full protection against disturbances caused to radio and TV reception when such equipment is used within distances given in Table 1.

    This European Standard is not applicable for apparatus which are manufactured before the date of its publication as EN.

    General Product Information - (Show below) - (Hide below)

    Committee MHE/4
    Development Note Supersedes 95/710913 DC. (08/2004) Supersedes 02/700414 DC. (12/2005) Supersedes 12/30258326 DC. (04/2014)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    05/30128013 DC : DRAFT JULY 2005 BS 5655-12 - LIFTS AND SERVICE LIFTS - PART 12: CODE OF PRACTICE FOR THE UNDERTAKING OF MODIFICATIONS TO EXISTING HYDRAULIC LIFTS
    BS 6440:2011 Powered vertical lifting platforms having non-enclosed or partially enclosed liftways intended for use by persons with impaired mobility. Specification
    BS 5655-11:2005 Lifts and service lifts Code of practice for the undertaking of modifications to existing electric lifts
    BS 5900:2012 Powered homelifts with partially enclosed carriers and no liftway enclosures. Specification
    BS 5655-12:2005 Lifts and service lifts Code of practice for the undertaking of modifications to existing hydraulic lifts
    05/30128010 DC : DRAFT JUL 2005 BS 5655-11 - LIFTS AND SERVICE LIFTS - PART 11: CODE OF PRACTICE FOR THE UNDERTAKING OF MODIFICATIONS TO EXISTING ELECTRIC LIFTS
    11/30194294 DC : 0 BS 6440 - POWERED LIFTING PLATFORMS WITH NON-ENCLOSED LIFTWAYS FOR USE BY PERSONS WITH LIMITED MOBILITY - SPECIFICATION
    BS 5655-6:2002 Lifts and service lifts Code of practice for the selection and installation of new lifts
    BS 5655-6:2011 Lifts and service lifts Code of practice for the selection, installation and location of new lifts
    04/30089457 DC : DRAFT APR 2004 BS 5656-2 - SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF ESCALATORS AND PASSENGER CONVEYORS - SELECTION, INSTALLATION AND LOCATION OF NEW ESCALATORS AND MOVING WALKS
    BS 5656-2:2004 Escalator and moving walks. Safety rules for the construction and installation of escalators and moving walks Code of practice for the selection, installation and location of new escalators and moving walks
    11/30194292 DC : 0 BS 5900 - POWERED HOME LIFTS WITH FULLY OR PARTIALLY ENCLOSED CARS AND NO LIFT-WELL ENCLOSURES - SPECIFICATION
    11/30229088 DC : 0 BS 5655-6 - LIFTS AND SERVICE LIFTS - PART 6: CODE OF PRACTICE FOR THE SELECTION AND INSTALLATION OF NEW LIFTS

    Standards Referencing This Book - (Show below) - (Hide below)

    CISPR 14-1:2016 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
    IEC 61000-6-4:2006+AMD1:2010 CSV ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
    IEC 61000-3-11 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-11: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS - EQUIPMENT WITH RATED CURRENT <= 75 A AND SUBJECT TO CONDITIONAL CONNECTION
    EN 61000-6-3:2007/A1:2011/AC:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010)
    EN 61000-3-11:2000 Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current
    IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
    2004/108/EC : 2004 DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC
    EN 115-1:2017 Safety of escalators and moving walks - Part 1: Construction and installation
    EN 81-1:1998+A3:2009 Safety rules for the construction and installation of lifts - Part 1: Electric lifts
    ISO 12100:2010 Safety of machinery — General principles for design — Risk assessment and risk reduction
    CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
    IEC 61000-6-3:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
    EN 55022:2010/AC:2011 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008)
    EN 61000-6-4:2007/A1:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
    EN 81-2 : 1998 + A3 2009 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 2: HYDRAULIC LIFTS
    EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
    EN ISO 12100:2010 Safety of machinery - General principles for design - Risk assessment and risk reduction (ISO 12100:2010)
    IEC 61000-6-4:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
    EN 61000-3-12:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011)
    CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
    EN 55014-1:2017 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
    IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective