• BS EN 12022:1999

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Blood-gas exchangers

    Available format(s):  Hardcopy, PDF

    Superseded date:  31-12-2014

    Language(s):  English

    Published date:  15-06-1999

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Definitions
    4 Requirements
        4.1 Biological characteristics
        4.2 Physical characteristics
        4.3 Performance characteristics
    5 Compliance tests and measurements
        5.1 General
        5.2 Biological characteristics
        5.3 Physical characteristics
        5.4 Performance characteristics
    6 Information supplied by the manufacturer
        6.1 Information to be given on the blood-gas
              exchanger
        6.2 Information to be given on the packaging
        6.3 Information to be given in the accompanying
              documents
    7 Packaging
    Annex A (informative) Bibliography

    Abstract - (Show below) - (Hide below)

    Defines requirements for single-use, sterile, extracorporeal blood-gas exchangers intended for supply of oxygen to, and removal of carbon dioxide from, the blood of humans. Applicable to heat exchangers that are integral parts of blood-gas exchangers and to external equipment unique to the use of the device. Not applicable to liquid exchangers, separate heat exchangers, implanted blood-gas exchangers, extracorporeal circuits (blood-tubing), separate ancillary devices.

    Scope - (Show below) - (Hide below)

    This European Standard specifies requirements for sterile, single-use, extracorporeal blood-gas exchangers intended for supply of oxygen to, and removal of carbon dioxide from, the blood of humans.

    This European Standard also applies to heat exchangers that are integral parts of blood-gas exchangers and to external equipment unique to the use of the device.

    This European Standard does not apply to:

    • implanted blood-gas exchangers;

    • liquid exchangers;

    • extracorporeal circuits (blood tubing);

    • separate heat exchangers;

    • separate ancillary devices.

    General Product Information - (Show below) - (Hide below)

    Committee CH/150/2
    Development Note Supersedes 95/562596 DC (08/2004)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 556:1994 + A1:1998 STERILIZATION OF MEDICAL DEVICES - REQUIREMENTS FOR TERMINALLY-STERILIZED MEDICAL DEVICES TO BE LABELLED "STERILE"
    EN 550 : 1994 STERILIZATION OF MEDICAL DEVICES - VALIDATION AND ROUTINE CONTROL OF ETHYLENE OXIDE STERILIZATION
    EN ISO 10993-11:2009 Biological evaluation of medical devices - Part 11: Tests for systemic toxicity (ISO 10993-11:2006)
    EN 46001 : 1996 QUALITY SYSTEMS - MEDICAL DEVICES - PARTICULAR REQUIREMENTS FOR THE APPLICATION OF EN ISO 9001
    EN ISO 9002:1994/AC:1997 QUALITY SYSTEMS - SPECIFICATION FOR PRODUCTION AND INSTALLATION
    EN ISO 10993-7 : 2008 COR 2009 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS (ISO 10993-7:2008/COR 1:2009)
    EN 1283 : 1996 HAEMODIALYSERS, HAEMODIAFILTERS, HAEMOFILTERS, HAEMOCONCENTRATORS AND THEIR EXTRACORPOREAL CIRCUITS
    EN 552:1994/A2:2000 STERILIZATION OF MEDICAL DEVICES - VALIDATION AND ROUTINE CONTROL OF STERILIZATION BY IRRADIATION
    EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
    ISO 10993-11:2017 Biological evaluation of medical devices — Part 11: Tests for systemic toxicity
    ISO 10993-7:2008 Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals
    ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
    EN 46002 : 1996 QUALITY SYSTEMS - MEDICAL DEVICES - PARTICULAR REQUIREMENTS FOR THE APPLICATION OF EN ISO 9002
    EN 980:2008 Symbols for use in the labelling of medical devices
    EN ISO 10993-1:2009/AC:2010 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS (ISO 10993-1:2009/COR 1:2010)
    EN 554 : 1994 STERILIZATION OF MEDICAL DEVICES - VALIDATION AND ROUTINE CONTROL OF STERILIZATION BY MOIST HEAT